Thank you for choosing FS S3700-24T4F Full-gigabit Access Switch. This guide is designed to familiarize you with the layout of the switch and describes how to deploy the switch in your network.
Accessories
Hardware Overview
Front Panel Ports
Ports | Description |
---|---|
RJ45 | 10/100/1000BASE-T ports for Ethernet connection |
SFP | Hot swappable SFP ports for 1G fiber connection |
Console | An RJ45 console port for serial management |
Front Panel Button
Button | Description |
---|---|
Reset | Keep the device powered on, press the button “RESET” for 6 seconds, and |
the system will return to the default setting.
Front Panel LEDs
LEDs | Status | Description |
---|---|---|
PWR | Green | Switch is powered on. |
SYS | Blinking Green | System is working properly. |
RJ45 | Orange | 10/100M connection. |
Green | 1000M connection. | |
Off | No signal transmission. | |
SFP | Green | 1000M connection. |
Off | No signal transmission. |
Back Panel
Site Environment
- Do not operate it in an area that exceeds an ambient temperature of 50°C.
- The installation site must be well ventilated. Ensure that there is adequate air flow around the switch.
- Be sure that the switch is level and stable to avoid any hazardous conditions.
- Do not install the equipment in a dusty environment.
- The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Installing
- Attach four rubber pads to the bottom.
- Place the chassis on a desk.
- Secure the mounting brackets to the two sides of the switch with eight M3 screws.
- Attach the switch to the rack using four M6 screws and cage nuts.
Grounding the Switch
- Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.
- Secure the grounding lug to the grounding point on the switch back panel with the washers and screws.
CAUTION: The earth connection must not be removed unless all supply connections have been disconnected.
Connecting to the power
- Plug the AC power cord into the power port on the back of the switch.
- Connect the other end of the power cord to an AC power source.
WARNING: Do not install power cables while the power is on.
Connecting to the RJ45 Ports
- Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other network devices.
- Connect the other end of the Ethernet cable to the RJ45 port of the switch.
Connecting to the SFP Ports
- Plug the compatible SFP transceiver into the SFP port.
- Connect a fiber optic cable to the fiber transceivers. Then connect the other end of the cable to another fiber device.
Connecting to the Console Port
- Connect the DB9 female connector of the console cable to RS-232 serial port on the computer.
- Insert the RJ45 connector into the RJ45 console port on the front of the switch.
Configuring the Switch
Configuring the Switch Using the Web-based interface
Step 1: Connect your computer to any Ethernet port of the switch using the
network cable.
Step 2: Set up the lap configuration on your computer. The lap address of your
computer should be set in the same subnet addresses of the switch.The lap
address is 192.168.1.x(“x” is any number from 2 to 254).
Step 3: Open a web browser window. Enter the default lP address of the switch
http://192.168.1.1 in the address bar and press Enter.
Step 4: When the login page appears choose the language that you prefer and
enter the username and password.
The default username is admin. The default password is admin.
Step 5: Click Sign in to display the web-based configuration page.
Configuring the Switch Using the Console Port
Step 1:Connect a computer to the switch’s console port using the supplied
console cable.
Step 2:Start the terminal simulation software such as HyperTerminal on the
computer.
Step 3:Configure the terminal simulation with the following parameters:
- 115200 bits per second
- 8 data bits
- no parity
- 1 stop bit
- no flow control
Step 4:Enter the username and password. The default username is admin. The default password is admin.
Troubleshooting
Power LED Working Abnormally
- Check the power cable connections at the switch and the power source.
- Make sure the power cord used matches the voltage and frequency of your local power.
HyperTerminal Displaying Abnormally
- Make sure the power supply is normal and the console cable is properly connected.
- Check if the console cable is the right type.
- Check if the control cable driver is properly installed on the computer.
- Ensure the parameters of the HyperTerminal are correct.
Accessing the Web-based Configuration Page Unsuccessfully
- Check every port LED on the switch and make sure the Ethernet cable is connected properly.
- Try another port on the switch and make sure the Ethernet cable is suitable and works normally.
- Power off the switch. After a while, power it on again.
- Make sure the IP address of your PC is set within the subnet of the switch.
- If you still cannot access the configuration page, please restore the switch to its factory defaults.
Then the IP address of your PC should be set as 192.168.1.x (“x” is any number from 2 to 254) and Subnet Mask as 255.255.255.0.
Online Resources
- Download https://www.fs.com/products_support.html
- Help Center https://www.fs.com/service/fs_support.html
- Contact Us https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our
workmanship, we will offer a free return within 30 Days from the day you
receive your goods. This excludes any custom made items or tailored solutions.
Warranty: FS S3700-24T4F Switch enjoys 4 years limited warranty against
defect in materials or workmanship. For more details about warranty, please
check at https://www.fs.com/policies/warranty.html
**** Return: If you want to return item(s), information on how to return can
be found at https://www.fs.com/policies/day_return_policy.html
Compliance Information
FCC
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee hat interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this
device could void the user’s authority to operate the equipment.
Responsible party (only for FCC matter)
FS.COM Inc.
380 CenterPoint Blvd, New Castle, DE 19720, United States https://www.fs.com
FS.COM GmbH hereby declares that this device is in compliance with the Directive 2014/30/EU and 2014/35/EU. A copy of the EU Declaration of Conformity is available at www.fs.com/company/quality_control.html
FS.COM LIMITED
24F, Infor Center, No.19, Haitian 2nd Rd,
Beihai Community, Yehia Street, Nanshan
District, Shenzhen City
FS.COM GmbH
NOVA Gewerbepark Building 7, Am
Gild 7, 85375 Neufahrn bee Munich, Germany
Copyright © 2021 FS.COM All Rights Reserved.
References
- FS.com - HPC, Data Center, Enterprise, Telecom
- HPC, Data Centre, Enterprise, Telecom - FS.com United Kingdom
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- FS.com - Data Center, Enterprise, Telecom
- Data Center, Enterprise, Telecom - FS.com
- Kontakt - FS.com Deutschland
- Rückgaberecht - FS.com Deutschland
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- Technische Dokumente - FS.com Deutschland
- Hilfezentrum - FS.com Deutschland
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Data Center, Enterprise, Telecom - FS.com
- Data Center, Enterprise, Telecom - FS.com
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Documents techniques - FS.com France
- Centre d'aide - FS.com France
- Data Center, Enterprise, Telecom - FS.com
- Products Warranty - FS.com
- Technical Documents - FS.com
- Help Center - FS.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>