Introduction
- This product is a mini anemometer, which can measure air velocity and temperature.
- This product is a mini-anemometer has the characteristics of compact and portable, high contrast band induction backlight screen, comfortable hand feeling, etc.
- It uses a new low power chip design, supplemented by scientific algorithm, independent software innovation, independent circuit improvement, so as to achieve accuracy, stability, cost-effective beyond, and create benefits for users.
- It is easy to operate, convenient and fast to use, and can be used for daily environmental monitoring in residential areas, families, workshops, workplaces and other places.
Precautions Before Use
- Please read the instructions carefully before using.
- The operating ambient temperature of this product is (0-50) °C and the relative humidity (<80%) RH.
- Please do not expose this product to extreme temperatures (<-20°C or > 50°C) or to excessive humidity (>85%RH).
- This product is not waterproof, please wipe the surface with alcohol when cleaning.
- To obtain a stable and accurate degree, place the instrument in the measuring environment for 3-5 minutes.
- If you find any problem, please contact with the seller, do not disassemble and repair yourself.
Specification
Air Velocity Measurement
- Range 0.0 to 30.0 m/S
- Accuracy ‡0.5 ‡5%m/s
- Resolution 0.1 m/s
Temperature Measurement
- Temperature Range -20 to 50°C (-4 to 122°F)
- Accuracy ‡2°C (4°F)
- Overload Prompt Liquid crystal display “OL”
- Resolution 0.1°C/°F
- Operating temperature 0 to 50°C (32 to 122°F)
- Operation Humidity <80%RH
- Storage Temperature -10 to 60°C (14 to 140°F)
- Storage Humidity <80%RH
- Battery 3 x AAA Batteries
Meter Description
- Wind Speed Sensor
- Temperature Sensor
- LCD Display
- Units Switch Button
- Data Hold Button
- Power On/Off Button
- MAX/AVG Button
- Backlight On/Off Button
- Triangular Hole
- Battery Cover
LCD Description
- Maximum value measurement mode enable symbol
- Average measure mode enable symbol
- Data hold mode enable symbol
- Low battery indication symbol
- Wind speed data
- Unit of wind speed
- Auto Power Off mode enable symbol
- Wind speed level symbol
- Temperature data
- Temperature units
0perating Instructions
Button Instruction
UNITS Button
Switch Units of Wind Speed:
- Press the UNITS Button to switch units of wind speed.
- There are five units of wind speed, which are m/s, ft/min, km/h, MPH and knots.
- The switching order is: m/s-ft/min-km/h-MPH-knots-m/s.
- The default unit of booting is m/s.
Switch Units of Temperature:
- Long press the UNITS Button to switch units of temperature, which can be changed to degrees Celsius or Fahrenheit.
- The switching order is: °C-°F-0 c.
- The default unit of startup is °C.
Power Turn ON/OFF
- Simply press the Power On/Off Button to turn on.
- Press and hold the Power On/Off Button to turn off.
MAX/ AVG Button
- Press the MAX/AVG Button to switch to MAX /AVG mode.
- The order of switching is: NULL-AVG-MAX-NULL.
Data Hold Button
HOLD Mode Turn ON/OFF:
- Press the Data Hold Button to enter the HOLD mode, and the measured values of temperature and wind speed remain unchanged.
- Press the Data Hold Button again to exit the HOLD mode and enter the normal measurement mode.
APO Mode Turn ON/OFF:
- Long press the Data Hold Button to start/close the APO mode of the instrument.
- By default, the startup APO mode will be automatically turned on.
- Long press the Data Hold Button to turn off the automatic shutdown mode, and long press the Data Hold Button again to start the APO mode.
Backlight Button
- Press the Backlight Button to turn on backlight.
- Press the Backlight Button again to turn off backlight.
Auto Power Off Instruction
- When the device is turned on, the “APO” symbol appears on the screen, and APO function is started by default.
- If there is no button operation in the instrument, the device will automatically shut down within 10 minutes.
- Long press the Data Hold Button to cancel APO function.
Wind Symbol Instruction
- When wind speed is measured, The” ‘” symbol on the LCD interface represents the measurement degree of wind power.
- There are 5 levels to represent the real-time measurement of wind speed.
Low Battery Instruction
- When the low batty symbol “ ” appears on the LCD screen, it means the battery should be replaced .
- Open the battery case and replace the expired battery with a new battery [3x 1.5v battery] to avoid data misreading.
Announcements
- Do not place the instrument in an overheated environment to avoid damage to the chassis.
- The instrument hood should be carefully protected and avoid falling to avoid damaging the fan and causing abnormal data collection.
- Do not throw away the waste batteries after use, so as not to cause environmental pollution.
Install/Replace Batteries
- When the battery power is low, the instrument will be prompted with the low electric symbol” “, please replace the new AAA battery.
- Unscrew the back cover screw, open the battery cover and replace the battery.
- When not in use for a long time, please remove the battery to extend the service life and prevent battery leakage from damaging the instrument.
- Please pay attention to the polarity of the battery, wrong placement may cause damage to the product.
Maintenance and Cleaning
- If necessary, use wet cloth and non-irritating detergent to clean the equipment and wipe the machine case.
- Do not use corrosive or irritating cleaners.
- Clean the screen with a dry cloth.
- Please keep the instrument in an appropriate temperature and humidity environment.
- Do not immerse the product in water or other liquids.