The product is a whirlpool system that comes in two different series: Luxury Series and Builder Series. The Luxury Series has a blower and offers additional features like chromotherapy, wave mode, and automatic purge. The Builder Series has a pump and comes with an optional built-in water level sensor.
Product Usage Instructions
Luxury Series
Always use dedicated outlets for each power supply. To turn on the blower,
press the On/Off button once. The blower will start at 50% speed. Press the
button again to turn off the blower. While the blower is on, you can adjust
the speed by pressing and holding the System Speed button. Release the button
once you reach the desired speed. You can also change the wave mode by
pressing the Wave Mode button. Press once for Wave mode, twice for Pulse mode,
and three times to return to maximum speed. If the water level falls below the
water level sensor while the blower is on, an automatic purge will initiate in
thirty minutes to dry the air channels. After the purge cycle, the blower will
turn off. For chromotherapy, press the Chromotherapy button once to turn on
auxiliary equipment and set it to white light. Press again for a slow rainbow
cycle, again for a fast rainbow cycle, and again to cycle through Turquoise,
Blue, Magenta, Red, Orange, Yellow, Green. Press and hold for one second to
turn off auxiliary equipment.
Note : The blower hose is shipped loose and needs to be attached to the
blower and check valve before use. Tighten clamp around each end.
Builder Series
Always use dedicated outlets for each power supply. Fill the tub until the
highest jet is covered by at least 2 inches of water. Do not run the pump
without water in the tub. If the optional built-in water level sensor is
installed, fill the tub until the water level sensor pad is covered. Press the
On/Off button once to start the
pump and again to turn it off. The control box has a 10-minute timer that will
turn off the unit automatically. To continue your bath, simply push the button
to repeat the cycle.
Note : If water falls below the water level sensor while the pump is on,
the system will turn off. The control box has a 20-minute timer that will turn
off the unit automatically.
INSTALLER: To be removed for use by the occupant
operating instructions
AIRBATH®
Water Level Sensor
If water falls below water level sensor while blower is on, an automatic purge
will initiate in thirty minutes to dry the air channels.
Automatic Purge
Thirty minutes after the water falls below the water level sensor the blower
will start again for a one-minute purge cycle allowing piping to thoroughly
dry
AIRBATH® + LIGHT On/Off Key
-
1st Press: The blower starts at 50%.
-
2nd Press: The blower stops.
While the blower functions press and hold -
3 sec.: Wave – Speed will vary gradually from maximum to minimum
-
6 sec.: Pulse – Speed will go directly to minimum and then straight back to maximum.
System Speed
- 1st Press: Press and hold to increase the pump speed, release pressure at the desired speed.
- 2nd Press: Press and hold to decrease the pump speed, release pressure of the desired speed.
Chromotherapy
- 1st Press: Auxiliary equipment ON > White
- 2nd Press: Slow rainbow cycle
- 3rd Press: Fast rainbow cycle
- 4th Press: Turquoise, Blue, Magenta, Red, Orange, Yellow, Green Return to slow rainbow cycle
- Press and Hold 1 sec.: Auxiliary equipment OFF
Automatic Purge
(only available with models equipped with Airbath® )
Thirty minutes after the water falls below the water level sensor the blower
will start again for a one-minute purge cycle allowing piping to thoroughly
dry
Note: Blower hose for AirBath Systems is shipped loose:
- Remove red caps from blower and check valve.
- Attached grey hose to blower and check valve.
- Tighten clamp around each end.
BUILDER SERIES
The Builder Series whirlpool is equipped with an On/Off Button (fill tub
until the highest jet is covered by at least 2” of water. Do not run pump
without water in the tub.)
- Press the Button to start the pump.
- Press a second time to stop the pump. The Control Box is manufactured with a 10 minute timer that will turn off the unit automatically. To continue your bath, simply push the Button to repeat the cycle.
Note: If OPTIONAL built in water level sensor is installed on your tub, fill the tub with water until the water level sensor pad is covered. Now you can press the Button to start the pump.
LUXURY SERIES
- Press the Button to start the pump.
- Press a second time to stop the pump. The Control Box is manufactured with a 20 minute timer that will turn off the unit automatically. To continue your bath, simply push the Button to repeat the cycle.
Water Level Sensor
If water falls below water level sensor while pump is on, the system will turn
OFF.
PLATINUM SERIES OR LUXURY SERIES + LIGHT
Chromotherapy
- 1st Press: Auxiliary equipment ON > White
- 2nd Press: Slow rainbow cycle
- 3rd Press: Fast rainbow cycle
- 4th Press: Turquoise, Blue, Magenta, Red, Orange, Yellow, Green Return to slow rainbow cycle
- Press and Hold 1 sec.: Auxiliary equipment OFF
Water Level Sensor
If water falls below water level sensor while blower is on, the system will
turn OFF.
COMBO SERIES + LIGHT
-
Blower On/Off
1st Press: The blower starts at 50%
2nd Press: The blower stops. -
Blower System Speed
1st Press: Press and hold to increase the blower speed, release pressure at the desired speed.
2nd Press: Press and hold to decrease the blower speed, release pressure at the desired speed. -
Blower Wave Mode
1st Press: Wave – Speed will vary gradually from maximum to minimum.
2nd Press: Pulse – Speed will go directly to minimum and then straight back to maximum.
3rd Press: Returns to maximum speed.
Pump On/Off Chromotherapy
- 1st Press: Auxiliary equipment ON > White
- 2nd Press: Slow rainbow cycle
- 3rd Press: Fast rainbow cycle
- 4th Press: Turquoise, Blue, Magenta, Red, Orange, Yellow, Green Return to slow rainbow cycle
- Press and Hold 1 sec.: Auxiliary equipment OFF
Water Level Sensor
The system will turn OFF if the water level falls below the water level sensor
while pump is on.
If water falls below water level sensor while blower is on, an automatic purge
will initiate in thirty minutes to dry the air channels.
Automatic Purge
Thirty minutes after the water falls below the water level sensor the blower
will start again for a one-minute purge cycle allowing piping to thoroughly
dry.
Each system will automatically stop after 20 minutes.
**Note: Blower hose for AirBath Systems is shipped loose:
- Remove red caps from blower and check valve.
- Attached grey hose to blower and check valve.
- Tighten clamp around each end.
IMPORTANT: Keep these instructions with the Americh Installation
Instructions. These operating instructions are for units with systems. All
installation, warnings, warranties, and other such information can be found in
the Americh Installation Instructions. Go to www.americh.com for additional
copies.
Manufacturer recommends the use of Jet Fresh® or a similar system cleaning
solution to maintain your whirlpool or Airbath® System
Always check www.americh.com for the most updated
installation instructions
in compliance with
ANSI Z124.1 – 1995 ANSI A112.19.7 – 1987
ANSI A112.19.8 – 1987
City of Los Angeles M980036 and M820132