TOWN SM-36-R-STD-P Commercial Smoker Oven Owner’s Manual
- June 4, 2024
- TOWN
Table of Contents
- SM-36-R-STD-P Commercial Smoker Oven
- SMOKEHOUSE INSTALLATION INSTRUCTIONS
- OPERATING INSTRUCTIONS
- UNIT OPERATION: LIGHTING AND SHUT DOWN INSTRUCTIONS
- RECOMMENDED SEASONING INSTRUCTIONS BEFORE FIRST USE
- GENERAL GUIDELINES
- MAINTENANCE AND USER TIPS
- SMOKEHOUSE ACCESSORIES
- SMOKEHOUSE ACCESSORIES
- **
- SMOKEHOUSE SAFETY PILOT PARTS
- SMOKEHOUSE BURNER SYSTEM
- RECORD OF OWNERSHIP
- Documents / Resources
https://townfood.com/
Owner’s Manual
SM-36-R-STD-P Commercial Smoker Oven
DO NOT DISCARD INSTRUCTIONS. THIS MANUAL MUST REMAIN WITH THE UNIT FOR FUTURE REFERENCE. THIS EMERGENCY INFORMATION MUST BE PROMINENTLY DISPLAYED.
SMOKEHOUSE OWNER’S MANUAL SECTION 1 | INSTALLATION INSTRUCTIONS
When sold in the Commonwealth of Massachusetts this unit must be equipped with
an interlock, to only allow operation if the hood system is operational.
Installation of the interlock is the responsibility of the installer—it is not
supplied by the factory.
WARNING
Improper installation, adjustment, alteration, service, or maintenance can
cause property damage, injury, or death. Read the installation, operating, and
maintenance instructions thoroughly before installing or servicing this
equipment.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
IMPORTANT
Contact your local gas supplier for instructions if you smell gas near this
equipment.
Congratulations on your purchase of a Town Food Smokehouse. It will give
you many years of trouble-free use if it is properly used and maintained. You
can now produce delicious, juicy barbecue quickly and easily. Please call our
customer service department at 718/388-5650 with any questions regarding
equipment operation or care.
Be sure your new Smokehouse is properly set up. Components may have moved
during shipment. The following Items should be verified before proceeding with
installation:
- Ensure that left and right baffle tracks are set into their support clips. Each track has a front and rear support clip (not pictured).
- Remove the shipping bolt from the steel baffle on the baffle tracks. The baffle plate must not be resting on the burners. Position the baffle so the front and rear are about the same distance from the Smokehouse walls (not pictured).
- The water pan must be resting on the steel baffle.
- Ensure the safety grate is properly positioned on the drip skirt clips.
- The interior perforated top baffle must be set as shown, with the edges on the pan resting on the track (flat side up.)
SMOKEHOUSE INSTALLATION INSTRUCTIONS
Proper installation is vital for proper performance. Consult your equipment
dealer, utility company or online for assistance locating a qualified
installer. When uncrating, locate all components.
Each unit is provided with a baffle, two baffle tracks, a water pan, a safety
grate, a lighter rod, and six skewers. Refer to the sketch on page 2 and
verify proper component positioning.
THE INSTALLATION AREA MUST BE FREE AND CLEAR FROM COMBUSTIBLES
-
Set the Smokehouse in the position it is to occupy in the cooking area. Check that the unit is level. The adjustable feet on the legs may be used to level the unit.
-
The gas supply line must be of adequate size to ensure maximum efficiency of the unit and conform with the National Fuel Gas Code, ANSI-Z223.1
-
The installation must conform with local codes, or, in the absence of local codes, with the National Fuel Gas Code ANSI-Z223.1:
a) The appliance, and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system, at test pressures in excess of ½ PSIG.
b) The appliance must be isolated from the gas supply piping system, by closing its individual manual valve, during any pressure testing of the gas supply piping system, at test pressures equal or less than ½ PSIG. -
This appliance is designed for use with natural or propane (bottled) gas only and may be connected only to the type of gas for which it is equipped as specified on the rating plate secured to the front of the unit.
-
A smokehouse should be used under a hood with adequate ventilation.
-
Smokehouse installation must have rear clearance of 4” and side clearance of 4” from any combustible construction. Clearances for non-combustible construction are same as combustible clearances. Suitable for installation on non-combustible floors.
-
Materials such as wood, compressed paper, and plant fibers will ignite and burn. These substances must not be left near the unit. Local safety codes should be complied with to respect fire hazard avoidance.
-
The front of the unit must be kept clear to avoid restriction of air supply for combustion.
-
The unit must be installed in an area or room with sufficient fresh air supply, to ensure proper combustion.
-
There must be adequate clearance for air openings into the combustion chamber, servicing, and proper operation.
-
If the unit is supplied with casters, the installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANZI-Z21.69, and a Quick Disconnect device that complies with the Standard for Quick Disconnect Devices for Use with Gas Fuel ANSI-Z21.41, and adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement.
-
Ensure that if your unit is provided with casters on legs, the legs with locking casters must be installed in the front leg gussets. Restraining devices are required for caster-mounted equipment. Such restraining devices are to be well secured to the sides or rear of the unit.
-
Do not place the unit by the door or window. Air currents have an adverse effect on the operation.
-
Do not throw away these instructions. This manual must remain with the unit for future reference.
OPERATING INSTRUCTIONS
-
Materials such as wood, compressed paper, and plant fibers that will ignite and burn, must not be left near the unit. Local safety codes should be complied with respect to fire hazard avoidance.
-
The front of the unit must be kept clear to avoid restriction of air supply for combustion or ventilation for exhaust.
-
There must be adequate clearance for air openings into the combustion chamber, servicing, and proper operation.
-
The unit should be operated only with water pan in place and filled with water. Drippings, especially fat, will ignite if the unit is used without water in the water pan. Be sure to drain fat and refill the water pan, if the cooking process allows most of the water to evaporate, such as in a slow-cooking brisket.
-
If your unit is supplied with casters, there should be a restraint on the appliance to limit its movement. If disconnection of the restraint becomes necessary, be sure to reconnect the restraint after the appliance is returned to its originally-installed position.
-
This appliance is designed for use with Natural or Propane (bottled) gas only and may be connected only to the type of gas for which it is equipped, as specified on the rating plate secured to the front of the unit.
-
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI-Z223.1:
a) The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system, at test pressures in excess of 1 /2 PSIG
b) The appliance must be isolated from the gas supply piping system by closing its individual manual valve during any pressure testing of the gas supply piping system, at test pressures equal or less than 1 /2 PSIG. -
The gas supply line must be of adequate size to ensure maximum efficiency of the unit, and conform with the National Fuel Gas Code, ANSI-Z223.1
-
The unit must be installed in an area, or room, with sufficient fresh air supply, to ensure proper combustion— it cannot operate safely without a sufficient air supply.
-
Smokehouse installation must have rear clearance of 4” and side clearance of 4” from any combustible construction. Clearances for non-combustible construction are the same as combustible clearances, suitable for installation or non-combustible floors.
-
A smokehouse should be used under a hood with adequate ventilation.
-
Do not discard instructions. This manual must remain with the unit for future reference.
UNIT OPERATION: LIGHTING AND SHUT DOWN INSTRUCTIONS
Always follow the lighting and shutdown instructions below when operating your unit. A 5-minute complete shut-off period is required before lighting or relighting it. See figure 1 below.
- Check that all gas valves on the unit are turned OFF (lever handles in vertical position) before turning on the main gas line. Check for leaks using soapy water or another suitable leak detector. Do not use open flame for testing.
- The main burner valve shall be in the OFF position. Light a match and place it in the lighter rod. Position the burning match by the pilot burner in the combustion chamber of the Smokehouse. Depress the red button on safe control (pictured below) and light pilot.
- The pilot should light. Continue to hold the button for one minute, or until the pilot stays lit.
- Set the thermostat to the desired temperature.
- Turn the main burner valve counterclockwise to the ON position pictured below). Be sure that each burner has ignited with a clear, blue flame that is 3 / 4 ”-1” long.
- Turn the main burner valve to the OFF position when the unit is not in use.
- Set the thermostat to the minimum setting.
- In the event of power failure, blackout, or loss of gas, do not attempt to operate the unit.
FIGURE 1
MAIN BURNER VALVE, SAFETY CONTROL AND THERMOSTAT
RECOMMENDED SEASONING INSTRUCTIONS BEFORE FIRST USE
- Clean the Smokehouse interior and exterior with a damp towel.
- Turn valves clockwise to off. NOTE – Before operation of this unit, all pipes and connections must be tested using soapy water or an alternate safe method. Never use an open flame for testing.
- Using the lighter rod, light the Smokehouse, using the procedure outlined earlier in this booklet. Close the door. Set the thermostat temperature to 400˚ and let the unit operate for 15 minutes.
- Turn off the main gas valve. Wearing gloves, safety goggles, and head, and arm coverings, wipe the interior with any good quality cooking oil. Be sure bare skin is not exposed. Use caution when doing this procedure—the oven could still be very hot.
- The Interior should be wiped with oil, but not dripping. Close the door. Reset the thermostat to 400˚, and allow the Smokehouse to operate for another 15-20 minutes. At the end f this process, the interior will be hot, seasoned, and ready for cooking.
OVERVIEW FIRST TIME USERS CAN REQUEST A USER GUIDE FOR OPERATING TIPS
Town Food’s Smokehouses are designed for skewer roasting, and smoking of ribs,
tenderloin, duck, chicken and other cuts of meat. Other foods, such as roasts
and chicken wings, can be roasted using an optional rack system. The unique
flavor found in Smokehouse-cooked food is a result of the marinating process,
moisture retention by use of the water pan, and the smoke created by the
drippings of the meat, during the cooking process.
The water pan must be nearly full of water and seasonings at the start of the
cooking process. Brought to a boil by heat from the combustion chamber below,
the water mixes with drippings from the product above. Rising steam
continuously bastes and flavors the product being cooked. While the
steaming/basting process prevents shrinkage, dry heat radiates upward from the
combustion chamber rendering excess fat. This fat will fall on the hot drip
shields and smoke, creating a delicious barbecue taste that permeates the
meat, or into the water pan to continue the basting process.
Temperature control and length of cooking time are determined by the product
being cooked, desired texture, and the experience of the chef.
GENERAL GUIDELINES
The following capacities are approximate and intended to give the operator
some guidelines. There are 2 cooking levels of all sizes. Every unit is
supplied with 6 skewers. Each level will accommodate 3 skewers with
SM-24 10 slabs of ribs per skewer, 60 slabs total
SM-30 13 slabs of ribs per skewer, 78 slabs total
SM-36 16 slabs of ribs per skewer, 96 slabs total
Pork Tenderloin
Trim to a weight of approximately 1 ⁄ 2 lb. per section before marinating. Use
the same skewer capacity as ribs.
Peking Duck
Leave neck, head, and body intact. Clean and eviscerate duck through the vent,
then seal the vent by tying or sewing skin. Insert needle valve of air pump
into the neck, between skin and neck bones, to separate the skin from the
body, with a cushion of air. Quickly and carefully remove the air needle and
tie off the neck below the opening, so the skin and body remain separated by
the trapped air. Hang the duck using a #248008 duck hook. Hang the duck and
let it drip according to tradition. Cook by suspending the hooks from the
upper rest only. The lower rest will not be high enough.
There are nearly limitless applications for this unit. In our test kitchen, we
have prepared chicken wings, a rack of lamb, and smoked fish. Please call us
at 718/388-5650 with any questions.
MAINTENANCE AND USER TIPS
Never allow accumulations of grease to form anywhere! It is recommended that
the Smokehouse be cleaned after every use after it cools. Remove grate, racks,
and any utensils (skewers, hooks, etc.). Wash and replace the unit. The water
pan should be removed and emptied into a sink connected to a grease tap. Wash
the water pan, dry it, and replace it.
The interior of the unit should be washed using a mild detergent and metal
sponge. This should be done with the water pan in place to prevent spillage
from entering the combustion chamber. Rinse and dry the interior. Remove the
water pan and rinse it. Replace the water pan with the unit after drying.
Clean the exterior using a towel and mild detergent. Remove any baked
accumulations of grease using a metal sponge but this may scratch the exterior
finish of the Smokehouse. Remove the interior top baffles, no less than once a
month, and wash.
Maintenance
- Clean and season the Smokehouse interior regularly.
- Never use the unit with an empty or leaky water pan, or without a water pan.
- Do not operate the Smokehouse in an area with strong air currents — cooking will be uneven.
CAUTION
Do not operate the unit without a safety grate in place or a low water supply
in the pan.
USE OF OPTIONAL WOOD CHIP BOX SEE PAGE 9 FOR DESCRIPTIONS AND MODEL
NUMBERS
A Town Smokehouse uses the drippings from the fat of the product, and
marinade, to make smoke. Chip boxes are used to complement the Smokehouse’s
natural barbecue taste, with a smoky wood flavor.
-
Cook your product normally in the Smokehouse until it is almost finished.
-
Shut down the oven 10-15 minutes before the product is finished being barbecued. Turn off the oven by turning the gas valve counter-clockwise (figure1).
-
Fill the chip box with chunks or chips.
-
When the oven is cool enough to insert the chip box, carefully place it in front of the water pan Slide it down into the combustion chamber, in front of the heavy steel baffle. The clips on the front edge of the box allow it to hang on the lower part of the door frame, as shown in figures 2 and 3.
-
Refer to figure1and restart the oven. Turn off the burners after 5 minutes and allow the wood to smoke. Smoking can take 1 hour or more.
-
Remove the product when done. USE CAUTION — the meat will be very hot. If any ashes have fallen into the combustion chamber, clean them out before using the unit again.
SMOKEHOUSE ACCESSORIES
RACKS, RACK GUIDES, AND CHIP BOXES
Racks and wood chip boxes are popular additions. Units with serial numbers
starting with 55 will accept racks and rack guides without modification.
Earlier serial numbers will require replacement skewer rests that will accept
rack guides. Rack guides fit all units and are required if racks are used
STAINLESS STEEL RACKS
number | fits model | size |
---|
244332
244335
244336| SM-24
SM-30
SM-36| 17”x20
23”x20”
28 3 ⁄4” x 20”
STAINLESS STEEL RACK GUIDES
number | description |
---|---|
244009 | 9-level rack guide |
USING RACKS AND RACK GUIDES
- After cleaning rack guides, take note that the top of the guide has a hook to be placed in a slot in the upper skewer rest.
- The front of the rack guide has a tab close to the front of each level. This tab acts as a stop that prevents shelves from being pulled out and falling out of the unit. (figure 1).
- There are left and right sides to the rack guides (figure 2). Each will have rack stops toward the front edge of each level.
- Hook the rack guides into the skewer rests, making sure the rack stop is located in toward the front of the unit.
- The racks may now be placed on the levels as needed.
WOOD CHIP BOXES
number | fits model | smoking time* |
---|
244000
244001
244002| SM-24
SM-30
SM-36| 30 minutes
45 minutes
90 minutes
*smoking times are approximate
SMOKEHOUSE ACCESSORIES
The standard exterior finish is galvanized with epoxy-coated legs. The
standard interior is a special heat-reflective, corrosion-resistant type of
steel liner. Standard accessories include 6 stainless steel skewers, stainless
steel water pan, and stainless steel safety grate.
EXTERIOR OPTIONS
number | description |
---|---|
250510 | set of (4) 4” casters, 2 with brake |
INTERIOR OPTIONS
Extra set of 6 stainless steel skewers
249420 fits SM-24
249425 fits SM-30
249430 fits SM-36
| SM-24| | SM-30| | SM-36|
---|---|---|---|---|---|---
part description| part number| size| part number|
size| part number| size
stainless steel water pan safety grate
baffle plate
interior top baffle
drip shields| 248620
244320
244020
248553
248720| 18” x 20”
143⁄3” x 181⁄2”
18” x 17”
213⁄8” x 17¼”
n/a| 248625
244325
244025
248556
248725| 20” x 24”
21” x 18 1/2”
18” x 23”
213⁄8” x 227⁄8”
n/a| 248630
244330
244030
248559
248730| 20” x 30”
27” x 181/2”
18” x 29”
213⁄8” x 22 3⁄8”
n/a
OPTIONAL ROASTING ACCESSORIES
Town offers these stainless steel hooks and needles to facilitate cooking
chicken, duck, and meats.
**
SMOKEHOUSE PARTS**
number | size/description |
---|
249006
249011
226102F
249007
249008
249047
226224| 36” thermocouple
3⁄8” IPS safety, pilot out, TS11K
3⁄8” x3⁄8” main gas valve
FDO thermostat with knob
thermostat knob only
universal gas pressure regulator
24” x1⁄4” compression pilot tubing
SMOKEHOUSE SAFETY PILOT PARTS
number | size/description |
---|
249012
249009
249006| Smokehouse safety pilot burner, natural
Smokehouse safety pilot burner, propane
36” thermocouple
SMOKEHOUSE BURNER SYSTEM
LIMITED WARRANTY
Town warrants all Smokehouses free from defects of workmanship or material for one (1) year from the invoice date, with the exception of safety pilot systems, which are covered by a 90-day warranty. Safety pilot systems installed without drip legs are not covered by this warranty. Defective parts returned prepaid will be repaired or replaced subject to our inspection and returned freight collection. Mishandling or abuse of equipment or components is not covered by this warranty, and repairs or replacements will be made at a nominal charge. Labor costs to return or replace parts in this equipment are the responsibility of the purchaser, as are proper installation and adjustments.
RECORD OF OWNERSHIP
FOR YOUR RECORDS, PLEASE RECORD THE FOLLOWING INFORMATION ABOUT YOUR
SMOKEHOUSE
MODEL NUMBER _
SERIAL NUMBER ___
DATE OF PURCHASE _
DEALER ___
DEALER’S PHONE NUMBER ____
© Town Food Service Equipment Company, Inc.
No part of this booklet or its illustrations may be copied or reproduced
without written authorization from Town Food Service Equipment Co., Inc.
https://townfood.com/
800/221.5032
718/388.5650
718/388.5860
**customerservice@townfood.com
****townfood.com**
Documents / Resources
| TOWN
SM-36-R-STD-P Commercial Smoker
Oven
[pdf] Owner's Manual
SM-36-R-STD-P, Commercial Smoker Oven, SM-36-R-STD-P Commercial Smoker Oven,
Smoker Oven, Oven
---|---
Read User Manual Online (PDF format)