DEFA 715000 Power Ipremium Charging Station for Electric Vehicles and Plug In Hybrids User Manual
- June 10, 2024
- DEFA
Table of Contents
- DEFA 715000 Power Ipremium Charging Station for Electric Vehicles and
- Product Information
- Product Safety Information
- Usage Instructions
- Description
- Safety information
- Main parts
- Symbols on the display
- Charging procedure
- Troubleshooting
- Store and protect
- Maintenance and care
- **Technical specification
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DEFA 715000 Power Ipremium Charging Station for Electric Vehicles and
Plug In Hybrids
Product Information
The product is a charging cable designed for Mode 3-charging of vehicles. It has a built-in RDC-DD that performs a self-test in every charging start-up cycle and every 24 hours. If the built-in RDC-DD is tripped, an error message will be displayed on the screen. To reset the built-in RDC-DD, unplug the charging cable from the vehicle and then plug it in again. The cable should not be used if it is defective or appears cracked, broken or otherwise damaged. Physical repairs must be executed by a licensed electrician.
Product Safety Information
Sections marked with the danger symbol draw attention to electrical voltages that represent a danger to life and limb. Actions contrary to these safety notices may lead to severe or fatal injury and must not be carried out under any circumstances. Sections marked with the warning symbol draw attention to additional hazards that may lead to damage to the cable itself or to other electrical devices. Actions marked with this symbol must be carried out with special care. Sections marked with the notice symbol draw attention to additional important information and special features that are necessary for the reliable operation of the device. Actions marked with this symbol should be carried out as required.
Usage Instructions
1. Plug the charging cable into the vehicle’s charging port.
2. The built-in RDC-DD will perform a self-test in every charging start-up cycle and every 24 hours.
3. If the built-in RDC-DD is tripped, an error message will be displayed on the screen.
4. To reset the built-in RDC-DD, unplug the charging cable from the vehicle and then plug it in again.
5. Do not use adapters or extension cords with the charging cable.
6. Keep the plug and charging station away from water. Do not expose to a direct jet, or splashes of water.
7. Handle the cable with care and do not subject it to strong force or impact. Do not pull, twist, tangle, drag, or step on the cable or plug.
8. If the outer shell of the cable is damaged, do not use it.
9. Any changes to the settings or the power connections must be executed by a licensed electrician.
Description
DEFA Power is a premium charging station for electric vehicles and plug-in
hybrids.
The charging station has been created with the user in mind. Smart features,
simple set-up, and powerful functionality, such as full dynamic load balancing
and active phase rotation, characterizes the device. The charging station can
be installed directly onto a wall or a pole, indoors or outdoors.
- Precise load balancing: Utilizes all available power, independent of cloud connection.
- Effective cooling: No derating ensures maximal charging power.
-
- Active phase rotation: It utilizes power on all phases.
- Intuitive display: Information and status sharing with the user.
- Small and compact: It fits everywhere and can easily be installed and handled.
- For everyone: It can handle all power and phase needs in European markets.
- Plug and play: Easy installation, setup and configuration via app.
- Powersmart: It minimizes charging cost by utilizing spot market energy prices and planning of charging curve.
A self-test of the built-in RDC-DD will be performed in every charging start-
up cycle and every 24h. If the built-in RDC-DD is tripped, a clear error
message will be displayed on the screen.
To reset the built-in RDC-DD, unplug the charging cable from the vehicle and
then plug it in again.
Safety information
- Important! Read this document before using the device. Failure to follow any of the instructions or warnings can result in material damage or personal injury.
- Important! If the device fails to behave according to instructions, immediately contact an electrician, responsible vendor or DEFA, see chapter Contact information.
- Important! DEFA Power must be installed, uninstalled, or repaired by a licensed electrician. These actions must be executed in accordance with national and local regulations.
- DANGER Sections marked with this symbol draw attention to electrical voltages that represent a danger to life and limb. Actions contrary to these safety notices may lead to severe or fatal injury. Actions contrary to these safety notices must not be carried out under any circumstances.
- WARNING Sections marked with this symbol draw attention to additional hazards that may lead to damage to the cable itself or to other electrical devices. Actions marked with this symbol must be carried out with special care.
- NOTICE Sections marked with this symbol draw attention to additional important information and special features that are necessary for the reliable operation of the device. Actions marked with this symbol should be carried out as required.
Danger
- Do not use if the outer shell has been damaged.
- Do not use the cable if it is defective or appears cracked, broken or otherwise damaged.
- Do not use adapters or extension cords.
- Physical repairs must be executed by a licensed electrician.
- Changes to the settings or the power connections must be executed by a licensed electrician.
Warning
- The product is designed only for Mode 3-charging of vehicles. Do not use it for any other purpose.
- Do not allow the cable to be under strain during charging.
- Do not allow water to enter the charging port while charging.
- Keep the plug and charging station away from water. Do not expose to a direct jet, or splashes of water.
Handling
- DANGER Ensure that the cable is never run over by a vehicle.
Handle the cable with care and do not subject it to strong force or impact. Do not pull, twist, tangle, drag, or step on the cable or plug.Always hold the cable by the plug when pulling it. Do not pull the cable itself.
Sorting
See chapter Store and protect for information about how to coil the cable
correctly.
- Always store the product with the cable coiled. Do not leave the cable on the ground after usage.
- Attach the plug cap to protect the vehicle plug when the product is not in use.
- Use the cable clip to coil the cable for when the product is not in use.
Main parts
- A. Charging unit
- B. Display
- C. RFID-reader
- D. Cable clip
- E. Plug
- F. Plug cap
- G. Cable
- H. Wall bracket
- J. Locking tool
- K. Rating label (public key)
Symbols on the display
Initialization
-
Open: Charger Ready
The charger is unlocked and ready to use. -
Locked: Charger Ready
Charger ready. Scan the QR-code and follow the instructions to start charging. This can only occur at chargers that are part of a facility. -
Vehicle connected (access control enabled): Scan QR-code/RFID
Scan the QR-code or the RFID-card to start authorization. -
Authorizing
Authorization is in progress. -
Access denied
The authorization was denied.
Charging
-
Preparing charging
The charging process is initialized. -
Charging
The vehicle is charging. -
Done or paused
The charging process is done or paused -
Done
Once the cable is disconnected, a summary of the charging process is shown.
Errors and Configuration
-
Error: Scan QR
Scan the QR-code on the display and follow the instructions to troubleshoot the issue. -
Error: Contact support phone
Call the displayed number to troubleshoot.
This can only occur at chargers that are part of a facility. -
Error: Contact CPO
Contact your charge point operator to support you. -
Configuration: Application Running
The configuration application is running. -
Configuration: Scan QR to setup
Scan the QR code on the display to initialize the setup.
Charging procedure
- NOTICE Please read the charging instructions in the vehicle’s manual before using the charging station.
- WARNING The plug locks to the vehicle inlet when charging starts. The plug stays locked until the charging procedure is finished. Always complete or end charging in the vehicle before unplugging (refer to the vehicle’s charging instruction for information about this).
Plug In
- Pick up the plug, uncoil the cable, and remove the plug cap
- Make sure that the charger is ready to be used. The Charger Ready icon should be visible on the display.
- Insert the plug into the vehicle inlet. The following symbol should now be visible on the display to indicate that charging is initialized.
- If authorization is enabled, that process has to finish before charging can begin. See the chapter Authorization for more information.
- Make sure that charging has started. The following symbol should now be visible on the display.
NOTICE The plug must be fully inserted into the inlet of the vehicle. Failure to connect will prevent the vehicle inlet from locking the plug in place and start charging.
Unplug
WARNING Complete or stop the charging process before unplugging. To stop charging before the vehicle is fully charged, see the vehicle’s manual.
Unlock the plug from the vehicle, refer to the vehicle’s manual for more information.
- Remove the plug from the vehicle inlet.
- Put on the plug cap onto the plug.
- Insert the cable into the clip.
Once the charger is disconnected, the display will show a summary of the charging session.
Authorization
If authorization is needed this icon will be shown on the display:
The authorization process can be completed by either:
- Scanning your RFID-tag on the RFID-scanner, if the charger is registered to your account in the user application.
- Opening the user application on your phone or scanning the QR code shown on the display. Follow the instructions shown on the screen.
If the authorization fails this icon will be shown on the display:
Check your user application or contact customer support of the facility.
Troubleshooting
The following symbols indicate that there has been an issue. In order to fix the issue, scan the QR-code on the screen and follow the instructions on the web page, or contact support.
- Error: Contact electrician
- Error: Contact CPO
- Authorization: No access
Store and protect
Coil the cable
Roll the cable around the charging unit. Make sure that the plug hangs with
the plug cap facing the ground. Attach the clip to the cable.
Use the plug cap
The plug strap can adjust the cap’s position. This prevents the cap from
collecting water and dirt, and keeps the cap clear of the vehicle.
Maintenance and care
WARNING Do not flush water on the charging station. Do not use harsh chemicals when cleaning.
Checking
- Keep the plug dry and check regularly for dust, dirt, pebbles, etc.
- Check the cable regularly for cracks and other damage.
Cleaning
- Use a damp cloth to clean. Do not use water or harsh chemicals.
Contact information
If you have any questions, contact your local vendor or visit
defa.com.
If you have any feedback on how the system or support can be improved, feel
free to give us your input at defa.com
**Technical specification
**
To download a full manual in your local language and see user instructions or video/animations, scan the QR code or visit defa.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>