HITACHI RA-08HV Window Inverter Type Room Air Conditioner Instruction Manual
- June 10, 2024
- Hitachi
Table of Contents
RA-08HV Window Inverter Type Room Air Conditioner
Product Information
The RA-08HV, RA-10HV, RA-15HV DC, RA-20HV, and RA-23HV are window inverter type room air conditioners manufactured by Johnson Controls-Hitachi Air Conditioning Philippines, Inc. These air conditioners come with safety precautions that must be followed to avoid accidents or damage to the unit. The installation of the air conditioner must be done by an authorized dealer or a certified technician to ensure proper installation and performance. The air conditioner has various functions and features that can be controlled using the unit display.
Product Usage Instructions
Precautions During Shifting or Maintenance
If the air conditioner is not running properly or showing a error, it is
recommended to contact the service center or the dealer from where the air
conditioner was purchased to avoid any accidents or damage to the unit. It is
important to read and understand the manual before using the air conditioner
and keep it for future reference.
Safety Precautions
It is important to follow the safety precautions mentioned in the manual to
avoid any accidents or injury. Failure to follow the instructions may lead to
serious consequences.
Installation Precautions
The installation of the air conditioner must be done by an authorized dealer or a certified technician to ensure proper installation and performance. The power cord must not be compressed or bent with a radius less than 20mm, and it should be secured using the cable tie supplied with the base-pan. The earth leakage circuit breaker must be installed to avoid any risk of electric shock or current leakage.
Usage Precautions
Do not insert your fingers or any other objects into the discharge air plenum
or return air grille while the fan is running at high speed. Do not splash
water on the unit as it may cause current leakage. Ensure that there is
sufficient oxygen in the room before using the air conditioner. Do not use the
air conditioner near a gas stove or any other heat source as it may cause
incomplete combustion. If you notice any abnormal noise or performance, turn
off the power switch for safety. Do not operate
the machine for too long if the vanes of the louver are facing down
or in the auto-swing mode as humid air may condensate on the louver and may
drip down water and wet the furniture.
Functions List and Features
The air conditioner has various functions and features that can be controlled using the unit display. The indication display on the front cover will change from (AUTO) to (HI) to (ME) to (LO) in a cycle.
RA-08HV RA-10HV RA-15HV DC
RA-20HV RA-23HV
INVERTER
Operation manual Window Inverter Type Room Air Conditioner
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
· If there is an error (burning odor, etc.), stop operation and turn off the power switch and then notify the
service center or the dealer from where the air conditioner was purchased. If the air conditioner keeps on
W running with the error, it may lead to failure, electric shock, fire, etc.
A R N
· To service the air conditioner, directly contact the service center or the dealer from where the air conditioner was purchased. If it is improperly repaired by yourself, there is a risk of electric shock or fire.
I · If the air conditioner is to be moved or relocated, directly contact the service center or the dealer from where N the air conditioner was purchased. If it is moved or relocated improperly by yourself, there is a risk of electric
shock or fire.
· If the power cord is damaged, it must be replaced by the manufacturer or by the service center or a technician to prevent danger
IMPORTANT:
READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS AIR CONDITIONER.
KEEP THIS MANUAL FOR FUTURE REFERENCE.
Johnson Controls-Hitachi Air Conditioning Philippines, Inc. 1A Binictican Drive, Subic Bay Industrial Park Phase II Subic Bay Freeport Zone, Philippines TEL: (02)362-4847 TEL(SERVICE): (02)362-3842
SAFETY PRECAUTIONS
· Read this section of “Safety precaution” carefully to understand proper
usage of this unit before use. · Pay special attentions to ” Warning” and ”
Caution” designations contained in this manual. The ” Warning”
designation may cause death a serious of injury if not followed correctly.
Failure to follow the instructions under the ” Caution” designation may also
cause possible serious consequence depending on the situation. Therefore, be
sure to observe these designations for your safety.
· In addition, this sign ” “shown in the diagram denotes prohibited items,
whereas ” ” denotes mandatory items.
· Be sure to keep this manual after reading. · The manufacturer is not liable
for maintenance and repair of the air conditioner as stipulated in the
warranty. The
same condition applies to any damage to this unit body/nearby property if you
fail to observe warning instructions in this manual/use of parts not supplied
from us. · This product uses non-flammable R410A refrigerant. While the
product is under installation or transport, except R410A refrigerant, please
do not charge other refrigerants, air, oxygen, propane, alcohol, or any
flammable material to avoid machine damage, blaze, or explosion. Be sure to
use the refrigerant specified by the manufacturer.
INSTALLATION PRECAUTIONS
· Air conditioner installation and its electrical wiring require a professional. Therefore, assign
only an authorized dealer or a certified technician to install your air conditioner and perform
W A R N I
its electrical wiring. Do not attempt to do it by yourself (charges are additional). If improperly performed by yourself, it may cause leakage, electric shock or fire. · Do not use a metal wire or copper wire as a fuse to prevent from failure or fire. · When installing, do not use an extended power cord or a power cord with excess
bending
N (radius less than 20mm). Also, use the cable tie supplied with the base-pan to secure it. Do not place the
G cord inside the unit body or it may cause short circuit or abnormal heat leading to a fire due to insulation
damage by an overly compressed cord.
· Use only on single outlet circuit exclusive for the air conditioner.
· Ensure the mounting support is firm and steady or there is a risk the unit
may fall. · To avoid electric shock in case of current leakage, be sure to
connect the air conditioner to the
ground. The ground wire diameter should be 2.5 mm² to 6 mm². Also, the end of
the ground wire must be crimped with a round terminal before securing it and
must not be loose by accident. Do not connect the ground wire to the gas pipe,
water pipe, lightning rod, and the telephone line. If the ground wire is not
installed properly, there is a risk of electric shock. If the unit is not
grounded, the protective circuit such as lightning striking protection will
not work properly.
· To avoid carelessness from power companies or other accidents that cause
over current to get into the unit via the ground wire resulting in damage to
the unit, be sure to install an earth leakage circuit breaker. Consult the
dealers (a registered water and electrical engineering dealer) for details. If
no earth leakage circuit breaker is
installed, there is a risk of accident such as electric shock to occur.
·e When installing near places with high humidity such as bathing facilities,
damp and humid places, basements, and places with frequent water accumulation,
be sure to install an earth leakage circuit breaker to prevent
current leakage. Consult the dealers (a registered water and electrical
engineering dealer) for details.
· Do not install at places where flammable objects and flammable gases exist. C If such objects and gases are around, a fire may occur.
C A A U
· The outdoor side should be well ventilated. Do not place any obstacle near the air discharge outlet, otherwise,
UT the unit performance may decrease and the noise increases.
OT I 0 N N I
· Do not place any object in front of the indoor side, otherwise, it may
affect airflow and Impede operation of the unit.
· Do not place any foreign material around the unit body, otherwise, it may
affect the performance of the unit. · Do not allow ejected heated air to face
your neighbors. Also, do not let water dripping, drainage, vibration,
noise, etc. interfere your neighbors.
· This unit is intended to be used for general family room air conditioning purpose, do not use it for storing food, animals and plants, precision machinery, fine art works, medicine, etc.
· When installing the water drain hose, be sure water can flow out smoothly. If installation is not proper, it is possible that water may flow inside the room or get your furniture wet.
· Plug the power cord to the right source, and the voltage required by the air
conditioner is 230V. · If the power of the air conditioner is connected to an
incorrect voltage, it will invariably burn out the electrical
parts.
· Be sure to firmly plug the power supply cord or it may cause short circuit
or heat resulting in danger of fire or electric shock.
· Periodically check the power cord plug and receptacle every year to ensure
that they are clean.
· While indoor unit front cover is not installed, do not operate the unit.
Moreover, be sure to take good measures against dust and dirt for unit body.
· Before the unit starts, be sure to check that the room has been cleaned up,
airborne matters and odors have been cleared, the unit body is clean. This
will prevent insufficient cooling or water leakage in later days.
USAGE PRECAUTIONS
· Do not insert anything like slender stick
WIA
into the discharge air plenum or return air grille as the fan is running at high speed,
R it is highly likely to cause danger.
N
I · When cleaning the unit body, never wash
N it with splashing water as there is a risk
G of current leakage.
· When thunder is likely to happen, for protecting the machine, stop operation
and turn off the power switch to prevent from failure.
· Do not operate the switch when your hand is wet to prevent electric shock.
· Do not let the discharge air plenum directly face your body for a long period of time, or it may have adverse effect to health.
· If a gas stove is used while the air conditioner is operating, be sure to
open the window often, or it is possible
to have insufficient oxygen inside.
· Do not let the airflow directly face the
· If the machine will not be used for a
gas stove, or it is likely to cause
long period of time, turn off the power
incomplete combustion.
switch for safety.
CUACAu
· When cleaning the unit body, be sure to turn off the power switch, or it may cause injury
TT as the fan is running at high speed inside.
·· Do not place animals or plants at the place to where the airflow is blowing directly, or it will have adverse effect to them.
I O
· When the window and the door are open (the humidity inside the room continuously exceeds 80%), the air
NN vanes of the louver are facing down or in the auto-swing mode, do not operate the machine for too long as it
is likely that humid air may condensate on the louver and may drip down water and wet the furniture.
· If there is a heat source (many people come in and out, a heating appliance is being used, etc.) that exceeds the
capacity of cooling or heating, the room temperature may not reach the desired setting level.
· If there is any abnormal noise is heard during unit operation, refer to the service center or to the dealer from
where the air conditioner was purchased.
· When installing at areas subjected to high salinity, sulfur, corrosive substance such as coastal areas and
hot springs, the heat exchanger of the unit or the circulation piping must be treated with anti-corrosion
coating. In addition, installation at places subjected to plenty of fumes, at hospitals where electromagnetic
wave is available, at places subject to dust and dirt or special environmental situations around installation,
consult the service center or the dealer from where the air conditioner was purchased first.
FUNCTIONS LIST AND FEATURES
UNIT DISPLAY
INDICATION DISPLAY ON THE FRONT COVER
FAN SPEED indicator light · When the unit is running, the light turns on. ·
When you press this button, the intensity of circulation
will change from (AUTO) to (HI) to (ME) to (LO) incycle.
POWERFUL indicator light · Use these buttons to start powerful operation.
When the unit is performing a powerful operation, this light turns on.
AUTO SWING indicator light When you press the button, the vertical louver will
automatically be swinging.
TIMER indicator light When the unit is preset with a timer, this light turns
on.
Infrared light receiving window
A “beep” sound will be generated when it receives the signal from the remote
controller.
REMOTE CONTROLLER
Room temperature display When the unit is powered up, the computer will
automatically detect the room temperature and display the current temperature.
(Indicates the error code when an error occurs)
Temperature button Press this button to raise or lower the temperature.
MODE indicator light When the unit is running, the light turns on. When you
press this button, the mode will change , from (COOL) to (FAN) to (DRY) in
cycle. ON/OFF button Press this button to start operation, press it again to
stop operation.
COOLING OPERATION Use the device for cooling when the outdoor temperature is above 10°C. If humidity is very high (over 80%) indoors, some dew may form on the air outlet grille of the indoor unit. Operating range of cooling: Indoor 21°C~32°C, Outdoor 10°C~4 2°C
Press the
button so that the display indicates “COOL”.
Set the desired FAN SPEED with the setting).
button (the display indicates the
AUTO: The FAN SPEED is HI at first and varies to ME automatically when the preset
temperature has been reached.
Set the desired room temperature with the buttons. The temperature setting and
the actual room temperature may vary somewhat depending on conditions.
Press the
button. Cooling operation starts with a beep. Press the button again to stop operation. The
cooling function does not start if the temperature setting is higher than the current room temperature (even
though the “RUNNING” (OPERATION) lamp lights). The cooling function will start as soon as you set the
temperature below the current room temperature.
DEHUMIDIFYING OPERATION Use the device for dehumidifying when the room temperature is above 16°C. When it is under 15°C, the dehumidifying function will not work.
Press the
button so that the display indicates “DRY” (DEHUMIDIFY).
The FAN SPEED is set at “LO” automatically.
Press the
button.
LOCK SETTING
After the lock setting is done, you can only use the
button and the (TEMP.)
button to change mode, the others are invalid.
Choose the operating mode, fan speed and setting temperature you want.
In the power off state, press and hold the
button first and press the lower
location of
(TEMP.) button later.
(Meanwhile, the
mark will be displayed on the remote controller.)
CANCEL: Repeat the procedure above to cancel the lock setting.
POWERFUL OPERATION
During the operation (DEHUMDIFYING, COOLING),
you should press the Press the
button to start the powerful operation button to start the powerful operation.
Every time you press the
button, it will increase the fan speed. If the
original fan speed is “Hi”, the fan speed will not change.
·
CANCEL: Press the
button again
CONTENT OF THE POWERFUL OPERATION
OUTDOOR SIDE INSTALLATION DISTANCE
HOW TO ASSEMBLE THE WATER DRAINAGE
ACCESSORY NAMES AND QUANTITIES
Main bracket X1
Battery X2
Fix plate X2
Remote Controller X1
Caulking Foam X1 Parts bag X1
Water drainage elbow X1
1 Insert the Drain Elbow into the Base Drain Hose.
2
Connect the Water Pipe Drain to the other end of the Drain Elbow
SERVICE GUIDELINES
Before cleaning, turn off the air conditioner first and unplug the power cord.
(Never unplug the cord with a wet hand to prevent electric shock.)
HOW TO SET THE TIMER
The timer may be used in two ways: (OFF-TIMER), (ON-TIMER). You can set only one kind of
timer. You can set the time in 1 to 24 hours for timer mode.
When the machine runs-off, press the
button.
You can set the time of running.
Press continuously to get rapid adjustment.
If you want to start the machine right away, you can press
reservation of time setting.
button to cancel all
When the machine runs-on, press
button.
You can set the time to stop. Press continuously to get rapid adjustment. If you want to stop the machine right away, you can press
button to cancel all reservation of time setting.
HOW TO SET THE SLEEP TIMER
This function will change the fan speed and the room temperature setting automatically
during sleep and you also can use the OFF-TIMER function together too.
You can set the time in 1 to 24 hours for sleep mode.
Press
button. Display indicates
Press continuously to get rapid adjustment. The SLEEP operation starts at beep sound, then the remote controller display will
show the reservation time and turn-off time.
CANCEL: Press the
button to cancel.
NOTICE
as the top priority to turn-on, The other timer setting are all invalid.
WIRING DIAGRAM
2. CLEANING THE FRONT COVER AND THE CABINET
It is easy for the front cover and the cabinet to get dirty. Wipe it regularly
with dry cloth. If it is dirty, use a wet and soft cloth to wipe. When the air
conditioner starts to operate, it may possibly blow out dusts. This is because
there are dusts accumulating on the discharge air plenum.
NOTICE : Do not wash the front cover with water over 50°C to prevent it
deformation. To prevent the front cover from damage, never wash it with
volatile oil, gasoline, thinner, grinding powder or a chemical abrasive cloth.
To avoid poor insulation and current leakage, never wash the air conditioner
directly with water.
3. HOW TO HANDLE THE AIR CONDITIONER AFTER THE USAGE SEASON IS OVER
When the air conditioner will not be used for a Iong period of time, turn on
the “Strong fan speed” on a clear day and run the unit for haIf a day so that
the inside of the unit can be dried. After the inside of the air conditioner
is dried, unplug the power cord or disengage the knife switch or the circuit
breaker exclusively set up for the air conditioner for safety.
INSTALLATION PRECAUTIONS
Use the screws supplied together with the unit to secure the front cover.
Before pulling out the unit body, first remove the screws and the parts for
fixation.
HOW TO ASSEMBLE THE INSTALLATION BRACKET AND THE WATER DRAINAGE
HOW TO ASSEMBLE THE INSTALLATION BRACKET
AFTER-SALE SERVICE AND WARRANTY
1. If an error is found, first check the following items.
unit: mm INSTALLATION DIMENSIONS
2. These are all normal indications:
For safety purposes, especially on high-rise buildings, bracket installation
can be done inside the room.
If the air conditioner does not resume standard operation after checking any
of the above items, please notify the service center or the dealer where the
air conditioner is purchased of the malfunction together with the air
conditioner model, manufacture number, and installation date recorded on the
warranty.
If the power cord/cord plug gets abnormally hot or the insulation sheath is
stripped/melted, unplug the power cord and immediately contact the service
center and the dealer where the air conditioner is purchased. Do not replace
the power cord by yourself to prevent danger!
The timer indicator light on the display flashes and the display screen shows
a number. (The cause of the error can be determined by the number of flashes,
and thus the problem can soon be
corrected. Therefore, before turning off the power switch, confirm the number
of flashes and the displayed number and then notify the service personnel.) 3.
Warranty The warranty is supplied with the unit body. In case of failure
during the warranty period, show your warranty to the service personnel and
you are entitled to have a free-of-charge service or a partial charge for
parts / materials to be replaced according to the prescribed items in the
warranty. The damaged copper tubes resulted from corrosion by sulfur gas or
salinity and refrigerant leakage are not covered by the warranty for free of
charge service. The warranty does not cover defects or malfunctions caused by
pests and insects.
65MP1433 RA-BA-L
HOW TO SET THE FROSTWASH
This function can effectively clean the dust, mold, oil, and other substances in the heat exchanger inside the indoor unit, but it cannot be completely removed.
When the air conditioner prompts for cleaning (the accumulated running time is
more than 100 hours), the room temperature display
flashes for 15
seconds when the unit is turned on and off.
Operating range
Outdoor temperature Room temperature Relative humidity
246 1032 3085%
1 Press the FROSTWASH button of the remote control when the body is stopped
The “beep” sound means that the freeze cleaning operation is started.
During the freezing and cleaning environment detection stage (30 seconds), the room temperature display flashes the word . When entering the execution stage, the room temperature display light
loop back and forth.
During the freeze cleaning operation, the body performs the following actions: Freeze cleaning Air drying
After the freeze wash operation is complete, the room temperature display will show the current temperature.
CANCEL Press the FROSTWASH button again or press the ON/OFF button to turn on the air conditioner function.
TURNING ON AND OFF THE CLEANING REMINDER
The cleaning reminder is set to on by default. If you want to turn off the
reminder, you can press and hold the FROSTWASH button on the remote control
for 3 seconds while the machine is running. The cleaning reminder is turned
off at the “beep” sound, and you can press it again to turn it back on.
Turning off the FrostWash function will cause the accumulated running time to
return to zero.
Freeze cleaning is not performed under the following conditions……… Within 60
minutes after the previous freezing cleaning is completed. During the
environmental detection stage, when the ambient temperature and humidity are
not within the operating range conditions. Air conditioner operation requests
will interfere with the freeze washing operation. Thus, freeze washing
operations will stop.
Symptoms that may occur when the freeze wash function is executed……
The longest execution time of freeze cleaning is about 86 minutes (the time
may be shorter depending on the environment). It will automatically swing to
the preset angle.
There will be a 30-second environment detection time before the freeze wash is
executed.
1
When freezing and washing, please close the doors and windows to avoid
condensation, which can cause the water to drop out of the body.
If the FrostWash function is interrupted while in operation, the drying
process may not be completed. It may cause the inside of the body to be prone
to mildew due to moisture. Please perform the FrostWash function when there is
sufficient time and ensure that the function is complete.
When freezing and washing, a layer of white frost will adhere to the surface
of the heat exchanger, which is a normal phenomenon.
During the freezing and cleaning process, the internal temperature of the
indoor unit will drop slightly, and mist may be emitted from the air outlet,
which is a normal phenomenon.
In performing freeze cleaning under different environmental conditions (such
as high temperature and low humidity), there may be no frost on the surface of
the heat exchanger, which is a normal phenomenon.
If the power is cut-off during the freeze cleaning process, the freeze
cleaning will not continue after restoring the power supply.
During freeze cleaning, the preset wind direction angle will automatically
adjust, so there will be a low motor running sound during the process. Also,
the heat exchanger will frost and defrost, which may create a (Crack, crack),
(Boom, boom) sound. It is a normal phenomenon and shall be performed when no
one is around.
When performing the FrostWash operation, the unit will create noise due to the
pressure change of frosting and defrosting applied on the system. It is
recommended to perform it during the day when no one is asleep or when going
out.
FrostWash cannot wash away all the dirt and mold. Please do regular inspection
and maintenance at the beginning or end of six months to one year, or the
beginning or end of the season. (Depending on room environment condition).
2
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>