FLIR Cx5 Thermal Imaging Camera
Product Information
FLIR Cx5
The FLIR Cx5 is a thermal imaging camera designed for routine testing,
inspection, and maintenance. The camera is installed in the FLIR Cx5 case,
which is manufactured under certified quality management systems according to
ISO 9001 standards. The temperature measurement accuracy of the camera is
applicable only when it is correctly installed in the case.
Product Usage Instructions
Opening and Installation
To open the FLIR Cx5 case, follow these steps:
- Locate the case latch on the bottom of the case.
- Slide the latch to the left to unlock the case.
- Lift the cover to open the case.
To install the FLIR C5 camera, follow these steps:
-
Slide the camera into the case from the top until it clicks
into place. -
Connect the camera’s USB-C connector to the port on the case’s
right side. -
Close the cover and slide the latch to the right to lock the
case.
Routine Testing, Inspection, and Maintenance
For routine testing, inspection, and maintenance of the FLIR Cx5 camera, follow these steps:
- Insert the restricted breathing test port into the side of the case to check for leaks.
- Inspect the camera and case for any damage or wear and tear.
- Perform any necessary maintenance according to EN60079-14 and EN60079-17 safety standards.
Safety Information
When using the FLIR Cx5 camera, follow these safety warnings:
-
Only use the camera in areas with a low risk of mechanical damage.
-
Do not remove the USB plug or recharge the camera in a hazardous area.
-
Do not disassemble the camera in a hazardous area.
-
Only use the FLIR Cx5 with the FLIR C5 pocket thermal imaging
camera -
If there are any grounds to believe the unit is no longer safe to use, it must be removed from service and measures taken to prevent its further unintentional use.
Notice to user
Important note
This manual provides important information about the FLIR Cx5 — a FLIR C5
camera installed in the certified FLIR Cx5 case. Before operating the device,
your must read, understand, and follow all instructions, warnings, and legal
disclaimers.
For information on the use and operation of the FLIR C5 camera, please refer
to the FLIR C5 user manual.
Online documentation
Our manuals are continuously updated and published online.
To access the FLIR Cx5 and FLIR C5 manuals, the FLIR Cx5 certifications, and
other product documentation, go to http://support.flir.com/resources/cx.
To access the manuals for our other products, as well as manuals for our
discon-tinued products, go to https://support.flir.com/resources/app.
Disclaimers
Measurement accuracy
The specification of the temperature measurement accuracy is only applicable
when the FLIR C5 is correctly installed in the FLIR Cx5 case.
Quality assurance
The Quality Management System under which the FLIR C5 camera is developed and
manufactured has been certified in accordance with the ISO 9001 standard.
The Quality Management Systems under which the FLIR Cx5 case is manufac-tured
has been certified in accordance with the following standards;
- EN ISO/IEC 80079-34
- UKSI 2016:1107 Schedule 3A, Part 2
FLIR Systems is committed to a policy of continuous development; therefore we reserve the right to make changes and improvements on any of the products without prior notice.
Copyright
© 2022 FLIR Systems, Inc. All rights reserved worldwide. No parts of the soft-
ware including source code may be reproduced, transmitted, transcribed or
translated into any language or computer language in any form or by any means,
electronic, magnetic, optical, manual or otherwise, without the prior written
per-mission of FLIR Systems.
The documentation must not, in whole or part, be copied, photocopied, repro-
duced, translated or transmitted to any electronic medium or machine readable
form without prior consent, in writing, from FLIR Systems.
Names and marks appearing on the products herein are either registered trade- marks or trademarks of FLIR Systems and/or its subsidiaries. All other trade- marks, trade names or company names referenced herein are used for identification only and are the property of their respective owners.
Safety information
Warnings related to a classified (potentially hazardous) area
WARNING
- This equipment shall only be used where there is a low risk of mechanical damage.
- Do not remove the USB plug in the hazardous area.
- Do no recharge in the hazardous area.
- Do not disassemble in the hazardous area.
- Only use the FLIR Cx5 with the FLIR C5 pocket thermal imaging camera.
- If there are any grounds to believe the unit is no longer safe to use, it must be removed from service and measures taken to prevent its further unintentional use.
Maintenance
For safety critical maintenance, refer to EN60079-14 and EN60079-17.
Safety information
Ex compliance marking
A non-removable label with the following markings is adhered to the rear
(screen side) of the case. If this label is missing or illegible, do not enter
the potentially hazardous area without consulting a suitably qualified person
.
Certifications
FLIR Cx5 operations
Introduction
The FLIR Cx5 case is a precision engineered device which upgrades the FLIR C5
thermal imaging camera to be suitable for safe use in potentially hazardous
(explosive) areas as defined by its certification.
Each FLIR Cx5 is supplied as standard with the following;
- FLIR C5 camera installed in FLIR Cx5 case
- Restricted breathing test port
- USB plug
- Transport pouch
USB charging and data transfer
WARNING
- Do not remove the USB plug, connect to the camera, download data, or charge within the potentially hazardous area.
- It is not necessary to remove the camera from the case to charge. Doing so frequently may cause damage to the case seals.
The FLIR Cx5 case is designed to accommodate the standard USB-C charge/download cable of the FLIR C5 camera.
- To access the USB-C port of the FLIR C5 camera, remove the USB plug lo-cated on the edge of the case.
- Connect the USB-C cable to the FLIR C5 socket and push until inserted, as shown in Figure 4.1. The camera can now be charged and connected to a PC.
- Once complete, disconnect the USB cable and replace with the USB plug.
Figure 4.1 FLIR Cx5 with USB cable connected.
Tripod mount
The FLIR Cx5 case incorporates a centralised, bottom mounted tripod boss with
a standard UNC ¼″-20.
Routine testing, inspection, and maintenance
WARNING
- Do not remove the USB plug, within the potentially hazardous area.
- Do not perform a restricted breathing test within the potentially hazardous area.
Routine testing, inspection, and maintenance
The FLIR Cx5 case relies upon its seals to prevent the entry of potentially
explo-sive gas into the enclosure. It is important therefore that these seals
are checked and where necessary replaced. Where applicable, ensure that
restricted breathing properties are checked after opening the case and that
the case is inspected in accordance with EN60079-14 and EN60079-17.
Inserting the restricted breathing test port
In order to periodically check the restricted breathing properties, the FLIR
Cx5 case is provided with a dedicated test port which is inserted in place of
the USB plug. The test port provides a barbed hose entry suitable for vacuum
capable ho-ses with an inside diameter of 5 mm.
-
To install the test port, first remove the USB plug located on the edge of the case.
-
Install the restricted breathing test port as shown in Figure 5.1.
Figure 5.1 FLIR Cx5 with restricted breathing test port. -
Once complete, remove the restricted breathing test port and replace with the USB plug.
Opening and installation
The FLIR Cx5 is delivered with the camera installed in the case. Should you for some reason need to remove the camera from the case, follow the instructions in this chapter to open the case and then reinstall the camera.
WARNING
The FLIR Cx5 certification is void if the unit is tampered with or if the FLIR
C5 is not correctly installed in the FLIR Cx5 case.
Do not exert excessive pressure onto the window in the FLIR Cx5 case.
To open the case and install the camera, the following minimum tools are required;
- H1.5 Hex bit screwdriver
- H2.0 Hex bit screwdriver
Opening the FLIR Cx5 case
-
Place the FLIR Cx5 case, lens face down onto a clean, flat surface.
-
Using the H1.5 hex screwdriver, remove the four (4) bolts securing the corner shock absorbers as shown in Figure 6.1.
-
Turn the FLIR Cx5 case over so that the lenses are facing upwards.
-
Using the H2.0 hex screwdriver, remove the eleven (11) bolts securing the case halves as shown in Figure 6.2.
Figure 6.2 FLIR Cx5 main retaining bolts. -
Gently push back the shock absorbers and separate the two halves of the case taking care not to lose any fixings.
Installing the FLIR C5 camera
Prior to installation, ensure that the touchscreen, lens, and window of the
FLIR C5 camera are clean and free from dust and dirt, as it will not be
possible to clean them once installed into the case.
-
Place the FLIR C5 camera into the case rear section with the touchscreen against the inner face of the case glass.
Figure 6.3 FLIR Cx5 case with FLIR C5 camera inserted. -
Spread the shock absorbers and place the FLIR Cx5 case front back into po-sition, then allow the shock absorbers to re-seat.
-
Using the H2.0 hex screwdriver, install all eleven (11) fixing bolts but do not tighten fully.
-
Once all fixing bolts are in place, complete the case closure by tightening the bolts in a diametrically opposed manner until finger tight.
-
Turn the FLIR Cx5 case so that the lenses face down, and then complete the installation of the four (4) shock absorber bolts using the H1.5 hex screwdriver.
Wlastebsitepage: http://www.flir.com
Customer support: http://support.flir.com
Copyright
© 2022, FLIR Systems, Inc. All rights reserved worldwide.
Disclaimer
Specifications subject to change without further notice. Models and
accessories subject to regional market considerations. License procedures may
apply. Products described herein may be subject to US Export Regulations.
Please refer to exportquestions@flir.com with any questions.
References
- support.flir.com
- Online documentation from FLIR Systems
- Thermal Imaging, Night Vision and Infrared Camera Systems | Teledyne FLIR
- Online documentation from FLIR Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>