BROAN NuTone LP510RSL Wall Switch User Guide
- June 11, 2024
- Broan NuTone
Table of Contents
- BROAN NuTone LP510RSL Wall Switch User Guide
- LP510R/LP510RSL QUICK START GUIDE WALL SWITCH OPERATION
- LP510R Lo-Profile 50-80-100 Selectable CFM & Continuous Run
- LP510RSL Lo-Profile 50-80-100 Selectable CFM, Continuous Run, Humidity
- LP510R/LP510RSL QUICK START GUIDE SETTINGS
- HIGH SPEED SETTING SWITCH
- LOW SPEED SETTING DIAL
- TIME DELAY SETTING DIAL
- HUMIDITY SETTING DIAL
- TROUBLESHOOTING FAQ
- My humidity sensing fan (LP510RSL) does not boost up to high speed mode
- My humidity sensing fan (LP510RSL) turns on to high speed boost mode too
- Why does my humidity sensing fan (LP510RSL) not function during some
- If the fan continuous to not operate after adjusting, contact Broan
- www.Broan-NuTone.com
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BROAN NuTone LP510RSL Wall Switch User Guide
LP510R/LP510RSL QUICK START GUIDE WALL SWITCH OPERATION
It is recommended that a 2-rocker switch is installed in the wall for the
LP510R fan model, and a 3-rocker switch is installed for the LP510RSL fan
model.
Switches (pictured right) are not included with the fan units. Humidity
sensing is a built-in feature for the LP510RSL fan and does not require a wall
switch for functionality.
LP510R Lo-Profile 50-80-100 Selectable CFM & Continuous Run
LP510RSL Lo-Profile 50-80-100 Selectable CFM, Continuous Run, Humidity
Sensing
LP510R/LP510RSL QUICK START GUIDE SETTINGS
HIGH SPEED SETTING SWITCH
Sets high speed Boost airflow level to 50, 80, or 100 CFM.
LOW SPEED SETTING DIAL
Sets low speed continuous airflow level from 30 CFM at the lowest setting up
to the air flow rate of the high speed boost airflow. % Setting is
based on high speed boost airflow. 50% of 80 CFM = 40 CFM continuous
TIME DELAY SETTING DIAL
Sets time delay level for LP510R model from 3 to 30 minutes and will switch the fan to the low- speed setting after the Boost switch is turned off for the set period. For LP510RSL the time delay is factory set to 20 minutes.
HUMIDITY SETTING DIAL
Sets humidity point for the LP510RSL model from 30% to 80% humidity and will switch the fan to the high-speed setting when the humidity in the room reaches the set level. Time delay is factory set to 20 minutes
TROUBLESHOOTING FAQ
Why is there a delay when I turn on my fan to low speed continuous airflow mode?
- The fan system is sensing the air pressure in the ductwork and then adjusting to corresponding fan This process can take about 10 seconds.When I flip on the Control Switch on my wall, my fan does not turn on.
- First, verify the function of your wall Starting with both wall switches in the off position, flip the first switch on. If the fan begins to run after approximately 10 seconds, this is your control switch. If the fan does not turn on, this is your boost switch.
- If the control switch still does not turn on the fan, the continuous run feature settings may need to be First, switch the power to the fan off at the service panel and lock or mark the disconnect with a warning tag and refer to instruction manual to adjust continuous airflow setting. If the dial is pointing directly at or below the 30 CFM setting, the continuous run feature is turned off and the fan will not operate in continuous run mode.
My humidity sensing fan (LP510RSL) does not boost up to high speed mode
when I turn my shower on.
- If the fan is located away from the shower area, the humidity point may not be triggered and the humidity setting may need to be adjusted to a lower First, switch the power to the fan off at the service panel and lock or mark the disconnect with a warning tag and refer to your instruction manual to adjust the humidity sensing rating.
My humidity sensing fan (LP510RSL) turns on to high speed boost mode too
often.
- The humidity sensor in the fan responds to either a rapid increase in humidity or the humidity in the room has gone above the user- adjustable set If the fan continuously responds to changing environmental conditions, the humidity setting may need to be increased. First, switch the power to the fan off at the service panel and lock or mark the disconnect with a warning tag and refer to your instruction manual to adjust the humidity sensing rating.
Why does my humidity sensing fan (LP510RSL) not function during some
seasons and weather changes?
- Temperature changes in a room due to a change in seasons and weather may cause the humidity sensor values to change. If this happens, follow the steps above to adjust the humidity setting
If the fan continuous to not operate after adjusting, contact Broan
Technical Support for further assistance. 1-800-637-1453
www.Broan-NuTone.com
Broan- NuTone LLC Hartford, Wisconsin 53027
©2022 Broan-NuTone LLC | Printed in U.S.A. 99851155A | 1/23
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>