Product Information

  • Design: This product is a cooking zone designed for surface-mount or flush-fit installation.
  • Cooking Zone: The cooking zone has a width of 268mm and a depth of 500mm.
  • Controls: The controls for the cooking zone are not specified in the manual.
  • Output: The output of the cooking zone is not specified in the manual.
  • Safety: The minimum safety distance required for installation is 50mm on one side, 200mm on one side, and 300mm on the opposite side. The minimum height for installation is at least 120mm and the minimum distance from the gas governor is 650mm.
  • Cut-out Dimensions (Surface-mounted): The cut-out dimensions for surface-mounted installation are a width of 268mm and a depth of 500mm.
  • Cut-out Dimensions (Flush-fit): The cut-out dimensions for flush-fit installation are a width of 268/292mm and a depth of 500/524mm.
  • Installation Requirements: The connection pressure for the hose to the appliance is Towngas 12.5 mbar/1.25 kPa. For detailed installation requirements and installation of several SmartLine elements, refer to the installation instruction booklet.

Product Usage Instructions

  1. Determine whether you want to install the cooking zone as a surface-mounted or flush-fit unit.
  2. Ensure that the minimum safety distances are met during installation: 50mm on one side, 200mm on one side, and 300mm on the opposite side. The minimum height for installation is at least 120mm and the minimum distance from the gas governor is 650mm.
  3. Refer to the installation instruction booklet for detailed installation requirements and installation of several SmartLine elements.
  4. Connect the hose to the appliance with a connection pressure of Towngas 12.5 mbar/1.25 kPa.
  5. After installation, refer to the user manual for control and output information.

SPECIFICATION

Design

  • 288 mm width, black glass ceramic surface
  • Enamelled cast iron ComfortClean pot rest
  • Flush-fit or surface-mounted installation

Cooking Zone

  • Single wok burner
  • Wok ring for flat or round based wok
  • Trivet for smaller pan

Controls

  • Electronic ignition with single-hand operation
  • High-quality metal rotary dial control

Output

  • Supplied for connection to Towngas
  • For pans 140-300mm Ø : 6000W

Safety

  • GasStop flame failure monitor

Optional Accessories

  • CSZL 7000 for installing several SmartLine units

DIMENSION

Cut-out Dimensions (Surface-mounted)Miele-CS7151-FL-SmartLine-Gas-Hob-
\(1\)

  • Width: 268 mm
  • Depth: 500 mm

Cut-out Dimensions (Flush-fit)Miele-CS7151-FL-SmartLine-Gas-Hob-
\(2\)

  • Width: 268/ 292 mm
  • Depth: 500/ 524 mm
  1. Front.
  2. Mains connection box with mains connection cable.
  3. Stepped cut-out (only suitable in a natural stone worktop).
  4. 12 mm wooden support frame is required for a solid wood, tiled, or glass worktop (must be provided on-site, not supplied).
  5. Gas connection R ½ “.

Appliance dimensions

  • Width: 288 mm
  • Depth: 520 mm
  • Height (exclude pot rest): 112 mm
  • Height for gas governor: at least 120 mm

Installation requirements

  • Voltage 220-240 V, Rated load 20W
  • Fuse rating 13 A, Electrical supply required
  • Length of cable 2000 mm, Without plug
  • Connection adapter/coupler from gas supply hose to appliance. Connection pressure: Towngas 12.5 mbar / 1.25 kPa

Minimum safety distance

  • Space to rear wall: 50 mm
  • Space to side /tall unit: 200 mm , and 300 mm on the opposite side
  • Space below hob: 30 mm
  • Space from hob to hood: min. 650 mm depends also on cooker hood

Please refer to installation instruction booklet for detailed installation requirement/installation of several SmartLine elements and information.

Miele (Hong Kong) Ltd
Manhattan Place, 41st Floor, 4101
23 Wang Tai Road,
Kowloon Bay,
Hong Kong
Tel: + 852 2610 1331
Fax: + 852 2610 1013

Due to continuous product improvement, Miele reserves the right to make changes to products and technical data without prior notice.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals