KOSTAL Plenticore Plus G2 User Guide

June 11, 2024
KOSTAL

KOSTAL Plenticore Plus G2

Product Information

PLENTICORE plus G2/PLENTICORE BI G2

The PLENTICORE plus G2/PLENTICORE BI G2 are inverters designed to convert the DC electricity generated by solar panels into AC electricity that can be used to power homes and businesses. These inverters are manufactured by KOSTAL Solar Electric GmbH and come with a range of features such as approved energy meters, battery storage, country settings for commissioning, service and guarantee conditions, and certificates. The inverter can be operated in approved countries and comes with an EU declaration of conformity. The product manual and other related information can be accessed on the KOSTAL Solar Electric website under the download section.

Product Usage Instructions

Mounting the Inverter

To mount the inverter, follow the below instructions:

  1. Download the user manual from the KOSTAL Solar Electric website.
  2. Refer to the user manual for detailed instructions on how to mount the inverter.
  3. Use the KOSTAL Solar App for iOS or Android or watch free video tutorials on their website for additional support.
  4. Ensure that the inverter is mounted at a height of 100mm.
  5. Use 1 x per DC input for mounting.
  6. Use 3 x min. DIN571 A2-70 6 x 50 screws for mounting.
  7. Ensure that the inverter is mounted in a location with an IP65 protection rating.

Further information on the inverter, such as detailed operating instructions, approved energy meters, battery storage, country settings for commissioning, approved countries in which the inverter can be operated, service and guarantee conditions, EU declaration of conformity and certificates can be found on the Internet in the download area for your product under.

www.kostal-solar-electric.com>Download.

KOSTAL-Plenticore-Plus-G2-fig-2

Danger! Risk of death due to electrical shock and discharge. Life- threatening voltages are present in the inverter. Only a qualified electrician may open and perform work on the
device. Always de-energize the device during installation, maintenance, and repairs, and secure it against being switched back on. The PV generators/cables may be live as soon
as they are exposed to light. DC cables must never be connected to or disconnected from the device during operation, as dangerous arcs may form. KOSTAL Solar Electric GmbH hereby declares that the inverter described in this document complies with the basic requirements and other relevant conditions of the directives listed below.

WARRANTY

Legal notice
KOSTAL Solar Electric GmbH Hanferstraße 6, 79108 Freiburg i. Br., Germany, Phone +49 (0)761 477 44 – 100, www.kostal-solar-electric.com.

Exclusion of liability
All names, trademarks, product names or other designations given in this manual may be legally protected even if these is not labeled as such (e.g.as a trademark). KOSTAL Solar Electric GmbH accepts no liability and gives no assurance that they can be freely used. The illustrations and texts have been compiled with great care. However, the possibility of errors cannot be ruled out. The compilation is made without any guarantee.

General note on gender equality
KOSTAL Solar Electric GmbH is aware of the importance of language with regard to the equality of women and men and always makes an effort to reflect this in the documentation. Nevertheless, for the sake of readability, we are unable to use non-gender-specific terms throughout and use the masculine form instead.

© 2022 KOSTAL Solar Electric GmbH
All rights reserved by KOSTAL Solar Electric GmbH, including those of reproduction by photocopy and storage in electronic media. Commercial use or distribution of the texts, displayed models, diagrams and photographs appearing in this product is not permitted. This manual may not be reproduced, stored, transmitted or translated in any form or by means of any medium – in whole or in part – without prior written permission.

Mounting inverter

KOSTAL-Plenticore-Plus-G2-fig-3

FEATURES

KOSTAL-Plenticore-Plus-G2-fig-4

System Overview

KOSTAL-Plenticore-Plus-G2-fig-5

Connect AC

KOSTAL-Plenticore-Plus-G2-fig-6

Connect the Energy meter in the grid position

KOSTAL-Plenticore-Plus-G2-fig-7

https://www.kostal-solar-electric.com/released-energy-meters-hybrid

Connect LAN / WiFi communication

KOSTAL-Plenticore-Plus-G2-fig-8

Connect battery communication

  1. Code required only for PLENTICORE plus.
  2. The battery only for PLENTICORE plus (optional with code PLENTICORE BI.

www.kostal-solar-electric.com

KOSTAL SOLAR WEBSHOP  shop.kostal-solar-electric.com

To connect a battery to the DC3 input of the PLENTICORE plus, an activation code battery must be purchased.

KOSTAL-Plenticore-Plus-G2-fig-19

Released batteries

https://www.kostal-solar-electric.com/plenticore_released_batteries

Close inverter

KOSTAL-Plenticore-Plus-G2-fig-11

Connect DC for PV/Battery

KOSTAL-Plenticore-Plus-G2-fig-12

Switch on the battery/inverter

KOSTAL-Plenticore-Plus-G2-fig-13

Initial Commissioning/Operation

KOSTAL-Plenticore-Plus-G2-fig-14

Login into the Webserver

KOSTAL-Plenticore-Plus-G2-fig-15

KOSTAL Solar Portal registration

KOSTAL-Plenticore-Plus-G2-fig-20

Activate free Smart Warranty

KOSTAL-Plenticore-Plus-G2-fig-17

Contact

www.kostal-solar-electric.com/service-and-support/contact

11/2022 – MA 12156953-0001 – DOC03013376-0001 – This manual is subject to technical changes and printing errors.
You can find current information at www.kostal-solar-electric.com. Manufacturer: KOSTAL Industrie Elektrik GmbH, Hagen, Germany

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>