DSC HSM2300 Power Supply Four High Current Output Modules Instruction Manual
- June 11, 2024
- DSC
Table of Contents
DSC HSM2300 Power Supply Four High Current Output Modules
Power Supply/Four High-Current Output Modules
The HSM2300 can provide up to 1.0A of additional current to the compatible
PowerSeries
Neo alarm controllers, models HS2016, HS2032, HS2064 and HS2128. The HSM2204
can provide up to 1.0A of additional current and add up to four high-current
programmable outputs.
This installation sheet shall be used in conjunction with the Installation
Manual of the DSC equipment to which the HSM2300 or HSM2204 is connected or
powered from (e.g. alarm controller, power supply, etc.).
General
This product meets the requirements of Class II, Grade 2 equipment as per EN50131- 1:2006+A1:2009, EN50131-3:2009 Type B, EN50131-6:2008 Type A.
Specifications
- Power supply Type A as per EN50131-6 Standard
- Temperature range: – 10°C to + 55°C (14°F to 131°F); for UL/ULC listed installation: 0 to +49°C (32°F to 122°F)
- Relative Humidity: 5% to 93% R.H. non-condensing
- Input rating: EU: 220V- 240Vac, 50Hz, 200mA; NA: 120V, 60Hz, 500mA. Only one board shall be powered from a transformer.
Note: For installations using the transformer mounted inside the cabinet, replace the fuse only with the same type (20mm) rated 250V/315mA.
- l Transformer required, mounted in the same enclosure and permanently connected (EU); for UL/ULC installations, use the plug-in adaptor model PTD1640U(UL) /PTD1640(ULC) or hardwired model FTC3716.
Note: For UL/ULC listed installations, do not connect transformer to receptacle controlled by a switch.
- Transformer secondary ratings: 16.5Vac, 40VA
- Board current draw: 40mA (set and unset state/alarm and non- alarm state)
- Board dimensions: 145mm x 83mm
- AUX output ratings: 10.8 to 12.5VDC
- Resettable fuse (PTC) used on circuit board instead of replaceable fuses
- Output ripple voltage: 600mVp-p max.
- No overvoltage protection devices required on the outputs
- Storage device: rechargeable battery, rated 12Vdc. Replace battery every 3-5 yrs.
- Battery capacity: 4Ah, 7Ah, or 14Ah (2 x 7Ah) max.
- Maximum standby time 24h (when using 14Ah battery capacity and AUX current limited to 500mA max.) Refer to Table 1.
- Recharging time: up to 85% in 24 hours (use high charging current setting)
- Low battery trouble indication threshold 11.5VDC, restoral level 12.5VDC
- Corbus (RED terminal) low voltage trouble threshold 9VDC
- Battery deep discharge protection (cut- off at 9.6 VDC)
Note: Main control panel and power supply shall be powered from the same
AC mains circuit.
Note: For EN50131-6:2008 compliant installations, use only one 12V/7Ah
battery for 12h of required standby time (500mA output current). Recharge time
to 80% is 72h Supervision for loss of primary power source (AC Fail), battery
fail, or battery low voltage (Battery Trouble) with indication provided on the
keypad.
Note: For T014 (INCERT) compliant installations, use two 12V/7Ah
batteries for 24H of required standby time (500mA output current) and the
enclosure model PowerUC1 (INCERT certified). The charging current shall be
high
Terminal Descriptions
Table: 1 Ratings
HOLISME/2204 Cur-
rent Draw 40mA
| ****
UL Resi Burg ULC Resi Burg
| ****
UL Com Burg
| UL Resi Fire UL Home Health Care ULC Resi
Fire ULC Com Burg
| ****
ULC Fire Monitoring
| ****
EN50131 Grade 2/Class II
---|---|---|---|---|---
Max. Aux Current
Loading
| ****
1A
| ****
1A
| ****
0.5A
| ****
0.5A
| ****
0.5A
UL/ULC Listed Enclos- ure
| ****
PC500C
| ****
CMC-1 PC4050CAR
| ****
PC5003C
| PC5003C (when used with a hardwired trans- former in an electrical box) PC4050CR
(red/transformer mounted
inside)
| ****
PC5003C Power UC1
Transformer Require- ments
| ****
16.5V, 40VA (plug-in type) PTC1640U (USA) PTC1640CG (CND)
| FTC3716 (cUL listed) 16.5V/37VA (Hardwired type, mounted inside the enclosure or outside
using electrical box)
| ****
16.5V/40VA (hard- wired type, mounted inside the cabinet)
Battery capacity
Requirements
| ****
7Ah
| ****
7Ah
| 14Ah (2x7Ah in par-
allel)
| ****
14Ah (2x7Ah in parallel)
| ****
7Ah
Standby Time| 4 hours| 4 hours| 24 hours| 24 hours| 12 hours
Alarm Time
| ****
4 minutes
| ****
15 minutes
| 4 min (UL resi fire) 5 min (Home Health Care and ULC Resi
Fire)
| ****
5 minutes (Alarm Trans- mission only)
| ****
N/A
Recharging current
setting
| ****
low (480mA)
| ****
low (480mA)
| ****
high (700mA)
| ****
high (700mA)
| ****
low/high (480/700mA)
AC – Supervised, the HSM2300/HSM2204 require a 16.5V/40VA transformer.
Connect the primary of the transformer to an unswitched AC source (maximum
current draw is 0.5A) and connect the secondary of the transformer (US market
only) to these terminals.
TAM- Used to tamper the cabinet in which the HSM2300/HSM2204 is mounted.
Connect a normally closed (NC) switch across TAM and BLK. If the tamper is not
being used connect a piece of wire across TAM and BLK to remove the trouble
condition. Tamper protect is required for UL/ULC commercial/residential
burglary installations.
AUX+ – Used to provide power for devices. Maximum current draw is not to
exceed 1000 mA. Connect the positive lead of powered devices to VAUX and the
negative to BLK or any COM terminal (01 to 04 for switched output or to BLK
for not switched output).
CORBUS – The 4-wire Corbus connection is used by the panel to communicate
with the module. Connect the RED, BLK, YEL and GRN terminals to the Corbus
terminals on the HS2016, HS2032, HS2064, or HS2128 main control.
O1 to O4 (HSM2204) – Wire the positive lead of the device to the AUX
terminal and the negative lead to the required output terminal O1 to O4.
IMPORTANT NOTE: Output O1 is supervised in the same manner as the Bell
Output of the compatible control panel. If O1 is not used, if no continuous
load is connected, or if a siren is connected, a 1000Ω resistor, DSC model
EOLR- 1 must be connected in order to prevent the indication of a trouble
condition. This diagram is an example of how to wire various devices to the
outputs.
Note: The HSM2204 is not suitable for fire alarm annunciation.
Enclosures
The HSM2300 or HSM2204 shall be installed in the metal enclosures listed
below. Tamper protection switches can be installed on all enclosures,
including door opening protection and/or removal from the mounting position.
Doors shall be secured using screws or keylock.
For EN50131-1 Grade 2 compliant installations, all holes on the side of the
cabinets shall be covered (plugged) if no accessories are installed in the
cabinet that will use these mounting holes
-
Model PC500C made of 22Ga steel, painted. 213mm(L) x 235mm(W) x 78 mm(H)
-
Model CMC- 1 made of 18Ga steel, painted. 287mm(L) x 298mm(W) x 80mm(H)
-
Model PC4050CAR made of 18Ga steel, painted. 376mm(L) x 305mm(W) x 125mm
(H) -
Model PC4050CR made of 18Ga steel, painted. 376mm(L) x 305mm(W) x 128mm(H)
-
Model Power UC1 made of 18Ga steel, painted. 356mm(L) x 319mm(W) x 115mm(H) Weight: 6.15Kg (PCB, Battery, XFRM)
-
Model PC5003C made of 22Ga steel, painted. 288mm(L) x 298mm(W) x 78mm(H), Weight: 4.5Kg (PCB, Battery, XFRM)
Battery Setting
A battery charge current setting in the panel is used to enable high charge current for the battery. Normally the battery charge current can be 240mA max, but when this option is enabled the module can charge the battery with up to 480mA of current. Section [982] [010] Options 1-4 can enable/disable the high current battery charge option for HSM2204 modules 1- 4 and [982] [020] Options 1-4 for the HSM2300.
Status LED
The HSM2300 and HSM2204 are equipped with status LEDs to indicate the current status of the module. If the HSM2300/2204 is operating correctly, the status LED will flash briefly every 10 seconds. When a trouble condition is present, the status LED will display a series of flashes then remain blank for 2 seconds. The number of flashes between blank periods indicates the trouble condition present as outlined in Table 2.
Table: 2 Trouble Conditions
Number of Flashes | Trouble Condition |
---|---|
1 | Module not enrolled |
2 | Panel supervision trouble |
3 | Corbus low voltage |
4 | Battery trouble |
5 | AC trouble |
6 | AUX trouble |
7 | Output 1 Trouble – HSM2204 only |
Enroll Modules
- Enter Installer Programming [] [8][Installer Code] [].
- Enter section [902] to enroll the module. Modules can be enrolled automatically or manually. In either case, the serial number of the device is used as an identifier. Select one of the enrollment options described below:
000 Auto Enroll
When this mode is selected, the total number of modules currently enrolled are
displayed on the keypad.
- After entering subsection [000], press the [*] key to begin auto enrollment of all new modules. As each device is enrolled, the keypad displays the model type, serial number and slot assignment. Devices are assigned to the next available slot.
- Use the < > keys to view the enrolled modules.
001 Manual Enroll
- After entering Installer Programming and section [902], enter subsection 001. Then enter [003] for HSM2204 or subsection [009] for HSM2300.
- When prompted, key in the serial number of the module, which is found on the back of the device. An error tone is sounded if an invalid serial number is received. Modules are enrolled into the next available slot for the device.
- To cancel enrollment of a module, press [#].
Deleting Modules
- Enter Installer Programming [] [8][Installer Code] [].
- Enter section [902] then subsection [109] for HSM2300 and subsection [110] forHSM2204.
- Scroll to the specific module you want to delete.
- Press [] to select the module then, when prompted, press [] again to delete.
Confirming Modules
To confirm enrollment of individual modules and to locate them physically:
- After entering section [903], scroll to the module type you want to confirm (109 for HSM2300, 110 for HSM2204). To view all modules, enter [000] after entering section [903].
- Press [*] to select the module type then scroll to the specific module you want to confirm.
- Press [*] to enter confirmation mode. The module’s serial number and slot number are displayed on the keypad and the status LEDs on the device flash. This continues until confirmation mode for the device is exited via the [#] key.
Limited Warranty
Digital Security Controls (DSC) warrants that for a period of twelve months
from the date of purchase, theproduct shall be free of defects in materials
and workmanship under normal use and that in fulfilment of any breach of such
warranty, DSCshall, at its option, repair or replace the defective equipment
upon return of the equipment to its factory. This warranty applies only to
defects in parts and workmanship and not todamage incurred in shipping or
handling, or damage due to causes beyond the control of DSC such as lightning,
excessive voltage, mechanical shock, water damage, or damage arising out of
abuse, alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, andis and shall
be in lieu of any other warranties, whether expressed or implied and other
obligations or liabilities on the part of DSC. This warranty contains the
entire warranty. Digital SecurityControls neither assumes responsibility
for,nor authorizes any other person purporting to act on its behalf to modify
or to change this warranty, nor to assume for it any other warranty or
liability concerning this product.In no event shall DSC beliable for any
direct or indirect or consequential damages, loss of anticipated profits, loss
of time other losses incurred by the buyer in connection with the purchase,
installation or operation or failure of this product.
Warning: Digital Security Controls recommends that the entire system be
completely tested on a regular basis. However, despite frequent testing, and
due to,but not limited to,criminal tampering or electrical disruption, it is
possible for this product to fail to perform as expected.
IMPORTANT – READ CAREFULLY: DSC Software purchased with or without
Products and Components is copyrighted and is purchased under the following
license terms:
ThisEnd-User License Agreement (“EULA”) is alegal agreement between You(the
company, individual or entity who acquired the software and any related
Hardware) and DigitalSecurity Controls, a division of TycoSafety Products
Canada Ltd.(“DSC”), the manufacturer of the integrated security systems and
the developer of the software and any related products or components
(“HARDWARE”)which You acquired. If the DSC software product (“SOFTWARE
PRODUCT” or “SOFTWARE”) is intended to be accompanied by hardware, and is NOT
accompanied by new HARDWARE, You may not use, copy or install the software
PRODUCT.
TheSOFTWARE PRODUCT includes computer software, and may include associated
media, printed materials, and“online” or electronic documentation.Any software
provided along with the software PRODUCT that is associated with a separate
end-user license agreement is licensed to you under the terms of that license
agreement.
By installing, copying, downloading, storing, accessing or otherwise using the
SOFTWARE PRODUCT, You agree unconditionally tobe bound by the terms of this
EULA, even if this EULA is deemed to be a modification of any previous
arrangement or contract. If you do not agree to the terms of this EULA,DSC is
unwilling to license the SOFTWARE PRODUCT to You, and you have no right to use
it.
SOFTWARE PRODUCT LICENSE
The SOFTWARE PRODUCT is protected by copyright laws and international
copyright treaties, as well as other intellectual property laws and treaties.
The
SOFTWARE PRODUCT is licensed, not sold.
-
GRANT OF LICENSE this EULA grants you the following rights:
- (a)Software Installation and Use- For each license you acquire, You may have only one copy of the SOFTWARE PRODUCT installed.
- (b)Storage/Network Use- The SOFTWARE PRODUCT may not be installed, accessed, displayed, run, shared or used concurrently on or from different computers, including a workstation, terminal or other digital electronic device(“Device”). In other words, if You have several workstations, you will have to acquire a license for each workstation where the SOFTWARE willbeused.
- (c)Backup Copy- You may make back-up copies of the software PRODUCT, but You may only have one copy per license installed at any given time. You may use the backup copy solely for archival purposes. Except as expressly provided in this EULA, You may not otherwise make copies of the software PRODUCT, including the printed materials accompanying the SOFTWARE.
-
DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS
-
(a)Limitations on Reverse Engineering, Decompilation and Disassembly – You may not reverse engineer, decompile, or disassemble the SOFTWARE PRODUCT, except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation. You may not make any changes or modifications to the software, without the written permission of an officer of DSC. You may not remove any proprietary notices, marks or labels from the Software Product.
You shall institute reasonable measures to ensure compliance with the terms and conditions of this EULA. -
(b)Separation of Components – TheSOFTWARE PRODUCT is licensed as a single product. Its component parts may not be separated for use on more than one HARDWAREunit.
-
(c)Single INTEGRATED PRODUCT – If You acquired this SOFTWARE withHARDWARE, then theSOFTWARE PRODUCT is licensed with theHARDWARE as a single integrated product. In this case, the software PRODUCT may only be used with the HARDWARE as set forth in this EULA.
-
(d)Rental – You may not rent, lease or lend the SOFTWARE PRODUCT. You may not make it available to others or post it on a server or website.
-
(e)Software Product Transfer – You may transfer all of Your rights under this EULA only as part of a permanent sale or transfer of the hardware, provided You retain no copies,You transfer all of the SOFTWARE PRODUCT (including all component parts, the media and printed materials, any upgrades and this EULA), and provided the recipient agrees to the terms of this EULA.If the software PRODUCT is an upgrade, any transfer must also include all prior versions of the SOFTWARE PRODUCT.
-
(f)Termination- Without prejudice to any other rights, DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA. In such event, You must destroy all copies of the SOFTWARE PRODUCT and all of its component parts.
-
(g)Trademarks – This EULA does not grant You any rights in connection with any trademarks or service marks of DSC or its suppliers.
-
-
COPYRIGHT – All title and intellectual property rights in and to the SOFTWARE PRODUCT (including but not limited to any images, photographs, and text incorporated into the SOFTWARE PRODUCT), the accompanying printed materials, and any copies of theSOFTWARE PRODUCT, are owned by DSC or its suppliers. You may not copy the printed materials accompanying the SOFTWARE PRODUCT. All title and intellectual property rights in and to thecontent whichmay be accessed through use of the SOFTWARE PRODUCT are the property of the respective content owner and may be protected by applicable copyright or other intellectual property laws and treaties. ThisEULA grants Younorights touse suchcontent. All rightsnot expressly granted under this EULA are reserved by DSC and its suppliers.
-
EXPORT RESTRICTIONS – You agree that You will not export or re-export the software PRODUCT toany country, person, or entity subject to Canadian export restrictions.
-
CHOICE OF LAW – This Software License Agreement is governed bythe lawsof the Province of Ontario, Canada.
-
ARBITRATION – All disputes arising in connection with this Agreement shallbe determined by final and binding arbitration in accordance with the Arbitration Act, and the parties agree to be bound by the arbitrator’s decision. The place of arbitration shall be Toronto, Canada, and the language of the arbitration shall be English.
LIMITED WARRANTY
-
(a)NO WARRANTY – DSC PROVIDES THESOFTWARE “ASIS” WITHOUT WARRANTY. DSCDOES NOT WARRANT THATTHE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE.
-
(b)CHANGES IN OPERATING ENVIRONMENT – DSC shall not be responsible for problems caused by changes in operating characteristics of the HARDWARE, or for problems in the interaction of theSOFTWARE PRODUCT with non-DSC- SOFTWARE or HARDWARE PRODUCTS.
-
(c)LIMITATION OF LIABILITY; WARRANTY REFLECTS ALLOCATION OF RISK – IN ANY EVENT, IF ANY STATUTEIMPLIES WARRANTIES OR CONDITIONS NOT AS STATED IN THIS LICENSE AGREEMENT, DSC’S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS LICENSE AGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU TO LICENSE THE SOFTWARE PRODUCT AND FIVE CANADIAN DOLLARS (CAD$5.00). BECAUSE SOME JURISDICTIONS DO
NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU. -
(d)DISCLAIMER OF WARRANTIES – THIS WARRANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED(INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC.DSC MAKES NO OTHER WARRANTIES. DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACTON ITS BEHALF TO MODIFY ORTO CHANGE THIS WARRANTY, NORTO ASSUME FORIT ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWARE PRODUCT.
-
(e)EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY – UNDER NO CIRCUMSTANCES SHALL DSCBE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, OR OTHER LEGAL THEORY.SUCH DAMAGES INCLUDE BUT ARE LIMITED TO, LOSS OF PROFITS, LOSS OF THE SOFTWARE PRODUCT ASSOCIATED EQUIPMENT, COST OF CAPITAL, COST OF SUBSTITUTE OR REPLACEMENT EQUIPMENT, FACILITIES OR SERVICES, DOWNTIME, PURCHASERS’ TIME, THE CLAIMS OF THIRD PARTIES, INCLUDING CUSTOMERS, AND INJURY TO PROPERTY.
WARNING: DSC recommends that the entire system be completely tested on a regular basis. However, despite frequent testing,and dueto, but not limited to, criminal tampering or electrical disruption, it is possible for this SOFTWARE product to fail to to perform as expected.
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital
Security Controls could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed
and used properly, in strict accordance with the manufacturer’s instructions,
may cause interference to radio and television reception. It has been type
tested and found to comply with the limits for Class B device in accordance
with the specifications in Subpart “B” of Part 15 of FCC Rules, which are
designed to provide reasonable protection against such interference in any
residential installation.
However,there is no guarantee that interference will not occur ina particular
installation.If this equipment does cause interference to television or radio
reception, which can be determined by turning the equipment off and on,the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Re-orient the receiving antenna
- Relocate the alarm control with respect to the receiver
- Move the alarm control away from thereceiver
- Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCCuseful: “How to Identify and resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington D.C.20402, Stock# 004-000-00345- 4.
Industry Canada
CAN ICES-3(B)/NMB-3(B)
EN CERTIFICATION
The TheModels HSM2204and HSM2300 Power supplies have been certified by
Teleficationaccording toEN50131- 1:2006 +A1:2009 andEN50131- 6:2008, for Grade
2, Class II, TypeA when installed inPC5003C enclosure.
©2015 Tyco Security Products, Toronto, Canada www.dsc.com Tech. Support: 1-800-387-3630
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>