Thermomirror TM2841 Mirror Demister Pad Installation Guide
- June 9, 2024
- Thermomirror
Table of Contents
Thermomirror Mirror Demisters
Installation Guide
TM2841 Mirror Demister Pad
Thank you for your purchase
Thank you for choosing a Thermogroup product. Our commitment to simple,
honest, on-time, quality service ensures that we are here to help throughout
every stage of your project from idea to installation and, most importantly,
after sales support.
This document will provide a step-by-step guide to a perfect installation as
well as details on the warranty and how to get technical support should you
need it. To ensure a safe, hassle-free installation to be proud of, please
take the time to read this guide in full before you start.
If you have any questions about your Thermomirror Mirror Demister or any of
our other products call our technical support team on 1300 989 464. We will do
our best to find a solution and will always give that little bit extra…
Thanks again for choosing a Thermogroup product.
Safety Information
Thermomirror demisters should be installed and tested by a qualified
electrician and in accordance with current local regulations. The Thermomirror
demister cannot be cut or pierced. Ensure the demister is a suitable size to
allow for the mirror fixings/brackets or to allow for 100mm spacing on all
sides in a glue-to-wall installation.
If you remove the Thermomirror demister pad from the back of the mirror it
cannot be reused as removal could easily damage it and prevent it from working
correctly.
Please read and understand this installation guide in full before commencing
installation. If you have any queries regarding installation, please call 1300
989 464.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
Means for disconnection must be incorporated in the fixed wiring in accordance
with the wiring rules. The disconnection may be achieved by incorporating a
switch in the fixed wiring in accordance with the wiring rules.
Do’s | Dont’s |
---|
Use this appliance for indoor only.
Ensure that the voltage of the mains supply corresponds to the voltage shown
on the demister.
Ensure that the cable and demister pad are undamaged before connecting to the
mains supply.
Render the unit inaccessible by the user after the installation.
Install only in environments where IP less than or equal to IP64 is accepted.
Ensure any timers or switches used are installed in correct zones according to
the IP rating of the timer/switch.
Ensure the installation is performed by a qualified electrician in accordance
with AS/NZS3000 and any current local electrical regulations.
Ensure the back of the mirror is free from dust/dirt before installing the
demister to ensure proper adhesion.
Install the demister on a RCD protected circuit.
Ensure multiple pads are wired in parallel.| Use for other applications
different from those specified.
Try in any way to open or service the device. If the power cord is damaged, it
cannot be replaced or repaired. In case of damage replace the entire unit.
Install the demister pad on mirrors in which holes are present. This condition
could cause breakage of the mirror due to thermal expansion.
Mount on metal surfaces, plastics, wood or cardboard, or anything other than
glass.
Punch, cut, bend, or apply on surfaces with spikes, blades, chips or anything
else that can damage the product.
Rest anything across the mirror surface that will prevent the heat from
dissipating.
Use the demister pad if the mirror has any damage.
Overlap demisters as this could cause a hotspot and possible damage to the
mirror.
Installation
The Thermomirror demister is to be installed directly on the back of the
mirror.
Before starting installation ensure that the demister is a suitable size for
the mirror.
For a glue-to-wall mirror installation, ensure there is 100mm spacing around
all edges of the Thermomirror to allow for sufficient adhesion between the
mirror and the wall.
For a hanging mirror, ensure the demister is located inside of the hanger
positions and that it will not cover any fixings or hangers.
The demister will not cover the entire mirror and will only demist the section
where the demister pad is applied so ensure that you install the demister in
the section of the mirror that will be suitable for use when the mirror is
installed.
The Thermomirror demister is a hardwired unit and needs to be installed by a
qualified electrician. This will need to be wired into the lighting circuit or
to a separate switch in
order to control the operation of the demister.
Ensure the mains power supply is switched off before attempting to carry out
any electrical work.
Bring the mains supply to the position of the demister and wire into a
suitable wall junction box. Ensure that the connections are not accessible by
the user.
Clean the back of the mirror to ensure there is no dust or dirt that will
affect the adhesion of the demister pad to the mirror. Do not use any
chemicals to clean the mirror. Wipe over with a soft damp cloth and allow to
dry completely before proceeding.
Peel off the protective backing paper from the Thermomirror and adhere to the
back of the mirror. For a glue-to-wall mirror, ensure that 100mm spacing is
left around all edges the demister. For a hanging mirror, the demister pad
needs to be located inside of any fixing/bracket positions — it cannot cover
the fixings or be cut or pierced.
To avoid air bubbles whilst sticking the demister pad, peel off the protective
paper a quarter of the way then stick the first part down and ease the
protective paper away whilst smoothing out the demister pad onto the mirror.
Gently rub over the demister surface to make it adhere firmly to the back of
the mirror.
Wire up the lead from the demister into the junction box ensuring that the
lead does not rub against or become trapped against the edge of the mirror.
Glue-to-wall mirrors must be installed onto a firm, flat, dry wall. Make sure
the mirror adhesive selected is neutral cure and is compatible with mirrors as
some adhesives will damage the mirror backing. Apply mirror adhesive to the
back of the mirror. Ensure the adhesive is run in vertical beads so that the
condensation behind the mirror can drain
away. Stick the mirror in position. The use of timber supports cut to the
height required off the vanity is also recommended for ease of installation,
this will keep the mirror at
the desired height and support the mirror until the adhesive cures.
For a hanging mirror, follow the instructions provided with the mirror to obtain suitable fixings and mount the mirror.
Warranty Information
Thermogroup covers all its products with a satisfaction guarantee. In
addition, Thermogroup will supply a replacement product where a fault is shown
to be caused by manufacture, materials or workmanship providing the goods have
been installed correctly and according to installation instructions. This
guarantee does not include removal, freight or installation costs.
To use the warranty, repair or service the customer must provide purchase
invoice/receipt.
If the product develops a fault within the warranty period due to normal wear
and tear, Thermogroup at its discretion will recognise whether it’s a faulty
product or not. If it is impossible or not economical for the manufacturer to
repair the product, the manufacturer will replace the faulty product with a
new unit of the same model or if there is no stock available of the same model
as the product, the manufacturer will replace the product with a new unit of a
similar size. No responsibility can be taken for altered dimensions and lining
up of existing holes.
The repair service offered within the warranty period only covers the faults
and problems as developed from the manufacturer’s errors. Any damage caused by
improper use or carelessness or incorrect wiring is not covered.
Thermogroup is not responsible for any monetary loss or injuries caused by
improper use of this product.
Our goods and services come with guarantees that cannot be excluded under the
Australian Consumer Law. For major failures with the service, you are
entitled: to cancel your service contract with us; and to a refund for the
unused portion, or to compensation for its reduced value.
You are also entitled to choose a refund or replacement for major failures
with goods. If a failure with the goods or a service does not amount to a
major failure, you are entitled to have the failure rectified in a reasonable
time. If this is not done you are entitled to a refund for the goods and to
cancel the contract for the service and obtain a refund of any unused portion.
You are also entitled to be compensated for any other reasonably foreseeable
loss or damage from a failure in the goods or service.
Technical Spefications
Stock Code| Size L x W (mm)| Heat Output (W)| Voltage|
Frequency
---|---|---|---|---
TM2828| 280 x 280| 16| 220-250V| 50Hz
TM2841| 280 x 410| 24| 220-250V| 50Hz
TM3545| 350 x 450| 38| 220-250V| 50Hz
TM4040| 400 x 400| 30| 220-250V| 50Hz
TM5050| 500 x 500| 55| 220-250V| 50Hz
TM4170| 410 x 700| 60| 220-250V| 50Hz
TM5868| 580 x 680| 80| 220-250V| 50Hz
TM5885| 580 x 850| 100| 220-250V| 50Hz
TM6010| 600 x 1000| 145| 220-250V| 50Hz
Supply Voltage| 220-250V
---|---
Wiring Method| Hardwired
Mounting Method| Fully self-adhesive
Protection Rating| IP64
Warranty| 10 Years
Max. Temperature on Glass (6mm Thick)| 35-40°C
Call us on 1300 368 631 or visit www.thermogroup.com.au
Complies with wiring standard AS/NZS60335.1 Thermogroup
PO Box 822
19 Ridley Ave
Leeton NSW 2705
1300 989 464
sales@thermogroup.com.au
www.thermogroup.com.au
E &EO © Thermogroup 2022