Foundations SI260H Stainless Steel Vertical Changing Station Instruction Manual

June 9, 2024
Foundations

Foundations-LOGO

Foundations SI260H Stainless Steel Vertical Changing Station

Foundations SI260H Stainless Steel Vertical Changing Station-
PRODUCT

Product Information

The 6WDLQOHVV6WHHO9HUWLFDO &KDQJLQJ6WDWLRQ is a product that provides users with high-quality sound output. It features an advanced sound system that ensures users enjoy a clear and crisp sound experience. The product comes with a remote control that allows users to adjust the volume and other settings from a distance. It also has a built-in FM radio that enables users to listen to their favorite radio stations. The product has a compact design that makes it easy to carry around and store.

Product Usage Instructions

  1. Unbox the product and take out all the components.
  2. Connect the power cable to the product and plug it into an electrical outlet.
  3. Turn on the product by pressing the power button located on the product or the remote control.
  4. To listen to music, connect your phone or music player to the product using an AUX cable, Bluetooth, or through a USB drive.
  5. To listen to the radio, press the FM button on the remote control and adjust the frequency until you find your desired radio station.
  6. To adjust the volume, use the volume buttons on the remote control or the product itself.
  7. To change other settings such as bass and treble, use the settings button on the remote control.
  8. When you are done using the product, turn it off and unplug it from the electrical outlet.

Thank you for purchasing a quality Foundations® product. Our goal is 100% consumer satisfaction!
If, for any reason you are not satisfied or if you have questions regarding your product or installation, please contact our customer service team at 330-722-5033 or www.foundations.com. Please DO NOT contact your distributor or reseller as we are better prepared to assist you.

WARNING

  • Failure to follow these warnings and the installation instructions could result in serious injury or death.
  • Read all instructions before installing diaper changing station. Keep these instructions. DO NOT discard.

ASSEMBLY INSTRUCTIONS

ADULT INSTALLATION REQUIRED.

TOOLS REQUIRED:

  • Level (A)
  • Measuring tape (B)
  • Power drill (C)Foundations SI260H Stainless Steel Vertical Changing Station-FIG-1
  • READ ALL INSTRUCTIONS BEFORE THE ASSEMBLY OF THE DIAPER CHANGING STATION
  • Unpack the carton and identify all parts.

WARNING

  • This changer has six (6) recess mounting holes.
  • The diaper changing station is no stronger than the anchors or walls to which they are attached and, therefore, MUST be firmly secured in order to support the weight they are intended to support. It is recommended that this unit be installed installation alas hard War. contact architect building contractor or professional Engineer for proper installation and hardware. Contact an architect or building contractor if any questions.
  • The child should never be left unattended.
  • Avoid serious injury from falling or sliding out. Always use a restraint system.
  • Adding excessive weight such as parcels, packages, or accessories to the unit or to the bag hooks that exceed the total weight limit of 50 pounds (22.7 kg) may cause the unit to be unstable or may cause a hazardous unstable condition to exist.

Parts Description

Door / Wall PlateFoundations SI260H Stainless Steel Vertical Changing
Station-FIG-2

IMPORTANT: Due to widely varied wall material, anchoring to be determined by architect or engineer.

A.D.A. Compliance:

Compliant when properly installed.

  • 306.3 Knee clearance.307.2
  • Maximum protruding objects.
  • 308.2 Forward reach.
  • 308.3 Side reach.
  • 309.4 Operation.
  • 902.3 Work Surface.

OPERATION:
Rotate the base downward. Place the infant on top of the changing surface. Use the restraint system as described below. After the child has been changed, remove the restraint system and rotate the base back up against the wall.

USE OF RESTRAINT SYSTEM:
Place the child so the restraint strap is located at the abdomen. Rotate top of the buckle upward and insert the strap in the buckle. Pull strap through buckle until snug against the infant. Rotate the top of the buckle down to lock the strap into place. Slide the red locking tab over the top of buckle (Fig. a). Reverse steps to loosen strap. MAINTENANCE AND CLEANING:
Check all hardware and components monthly or as required to ensure the hardware is tight and there are no missing or damaged components. Take unit out of service if any component is missing or damaged and contact customer service to order replacement parts. Do not substitute parts.
For replacement parts, contact customer service at 330-722-5033.
Clean by using a damp cloth with mild soap or mild multi-purpose cleaner. Do not use any strong chemical cleaners or cleaning agents that may be hazardous to children.

INSTALLATION

RECESSED

For A. D. A. compliance, the top of the lower double stud should be 30.5″ (78 cm) from the floor.

Recommended Blocking:
Wood double-stud blocking is necessary. Contact an architect and building official to make sure the blocking is adequate and complies with building codes (Fig. b).Foundations SI260H Stainless Steel Vertical Changing
Station-FIG-5

  1. Slide the changer into the blocking area and mark the mounting hole location on the blocking studs.
    HINT: This may require 2 additional people to help hold changer in position while you are marking the locations.

  2. Shim changer for a snug fit.

  3. Align holes in the changer with marked holes and secure using the appropriate fasteners (Fig. c).Foundations SI260H Stainless Steel Vertical Changing Station-FIG-6 NOTE: It is the installer’s responsibility to provide the correct fasteners and other substrates.

  4. Ensure all six (6) fasteners are tight.

SURFACE-MOUNT

Recommended Blocking:
If the walls do not have studs on the center, then additional blocking is necessary (Fig. d).Foundations SI260H Stainless Steel Vertical Changing
Station-FIG-7
Contact an architect or building contractor to make sure the blocking is adequate and complies with building codes.
For A. D. A. compliance, measure up 60 1/2″ (154 cm) from the floor and mark the wall. This locates the position for the top left attachment hole.

NOTE:

  • Changer MUST be mounted to studs (Fig. e).
  • This unit incorporates a finishing collar that seats behind the changers outside flange.
  • Center the collar as the unit is being tightened against the wall (Fig. f).Foundations SI260H Stainless Steel Vertical Changing Station-FIG-8

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals