PNI SafeHouse HS600 Wireless Alarm System User Manual
- June 9, 2024
- PNI SafeHouse
Table of Contents
- HS600 Wireless Alarm System
- Main functions
- Alarm system control via Tuya Smart application
- Main unit
- SOS button lights
- Connections panel
- Configuration
- Add/Delete remote controls
- Add/Delete wireless sensors
- Add/Delete RFID TAGs
- Pairing a wireless siren
- Record messages
- Automatic arming/disarming
- Query system settings via SMS
- Arm/Disarm the alarm system
- Disarming
- Panic alarm
- Technical specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Safe House HS600 Wireless Alarm System
User Manual
PNI Safe House HS600
Wireless alarm system
HS600 Wireless Alarm System
Warnings
Before using this product, please read the user manual carefully.
The installation and configuration of this alarm system requires basic
technical knowledge to allow a correct understanding of the technical terms
and procedures described in this manual.
Follow the step by step instructions and start with simple settings. After
making the settings, test the correct operation of the product.
Main functions
- Remote control via Tuya Smart application (Android/iOS)
- 2.4 inch color TFT screen
- Menu and voice prompts in 9 languages
- Built-in siren, wired indoor siren included in the package and the possibility of pairing a wireless outdoor siren
- Up to 90 wireless zones (sensors) and 3 wired zones (EOLR)
- Up to 8 smart sockets or relays
- Supports renaming areas, for example: door, bedroom, window, balcony, living room, smoke sensor, gas sensor, CO sensor, etc.
- Low battery warning for sensors
- Event log
- Alarm alert sent by phone call or SMS on preset phone numbers (up to 5 phone numbers can be set)
- Direct phone call via GSM
- Built-in tamper
- GSM 4G and WiFi communication
- Automatic time synchronization via GSM and WiFi
- System configuration via SMS
- Recorded alarm messages (up to 20 seconds/message)
- Remote arming/disarming via Tuya Smart application
- Scheduled arming/disarming
Burglary protection
Your alarm system has two modes of protection against burglary: Home arming
and Total arming.
Home arming (perimeter arming) only protects the perimeter, allowing you
to move freely inside the house.
Total arming protects the entire building.
Zones
The sensors paired to your alarm system will be assigned to different “zones”
(maximum 90 for wireless sensors and maximum 3 for wired sensors). For
example, the sensor on the front door of the house can be assigned to zone
01, the sensor on the window in the master bedroom in zone 02 and so on. The
zone number is displayed on the screen when an alarm or problem occurs on a
specific area.
Entry and Exit Delay
Your alarm system has been programmed with adjustable delay time that allows
you to leave the house after arming the system and disarm the system at the
entrance into the house, without triggering an alarm.
If you leave the house too late after arming the system or disarm the system
too late after entering the house, the system will trigger an alarm. Disarm
the system immediately.
The alarm and the event notifications on the phone
When an alarm is triggered, the built-in and the external siren will sound
until the system is disarmed or until the preset time interval for the siren
expires. A message will show up on the control panel screen with the area or
areas where the alarm was triggered. If set, the alarm system will call or
send SMS via the 4G GSM network to the preset phone numbers (maximum 5) or
will send notification via the mobile application (Tuya Smart).
Alarm system control via Tuya Smart application
Download the Tuya Smart app via Google Play or App Store or scanning the QR codes below:
|
---|---
https://play.google.com/store/apps/details?id=com.tuya.smart&hl=en|
https://apps.apple.com/us/app/tuyasmart/id1034649547
- Open the application, create an account and log in.
- Add your device by clicking the + icon in the upper right corner of the screen or by clicking the Add device button (this button only appears when you do not have any devices added to the application).
- Select the Sensors option on the left side of the screen.
- From the list of devices on the right side of the screen, select Alarm (Wi- Fi)
- Select the WiFi network you want to connect to and add the password.
- In the next interface, select the option EZ Mode from the upper right corner.
- Access the alarm system control panel menu WiFi->Airlink Configure
- Then tick Confirm the indicator is blinking rapidly. Click Next.
- The application will start scanning the nearby devices.
- After it identifies your device, you will receive the confirmation Added Successfully.
- To finish, click the button Done.
The application allows you to add accessories (remote controls and sensors),
to configure the system, to arm and disarm, to view the history log.
For details about the menu in the application, please read the explanations of
the alarm menu (page 12).
Main unit
Package contents:
- 1 x control unit
- 1 x wireless motion sensor
- 1 x wireless magnetic sensor
- 1 x wired indoor siren
- 2 x remote controls
- 2 x RFID TAGs
- 230V- 5V power adapter with USB
- USB- micro USB power cable
- Mounting accessories
Index | Item | Description |
---|---|---|
1 | **** Screen | 2.4 inch TFT screen. |
It displays time, menu, system status and alarm status information (the area
the alarm was triggered).
2| Speaker| It emits alarm sound and confirmation sounds.
---|---|---
3| Panic button (SOS)| Press to generate a panic alarm in case of fire or
personal emergency.
4| Arming/Home arming button| Press to arm the entire alarm system, perimeter
- interior.
Press twice to arm only the sensors programmed for “Home arming”. Interior protection is not activated, which allows movement through the house without triggering alarms.
5| Disarming| Press to disarm the system and turn off the audible alarm.
Double-click to clear warnings about accessory operation.
6| Up button| Scroll up to the desired function or menu.
7| Down button| Scroll down to the desired function or menu.
8| Cancel/Back| Back to the previous screen.
9| Enter| Select the option or go to the next interface
10| RFID reader| Bring the TAG closer to this area to arm/ disarm the system
SOS button lights
The LED flashes alternately | The system is in alarm state |
---|---|
The LED pulses | The system is armed |
The LED is constantly lit. | The system is disarmed |
Connections panel
Index | Description |
---|---|
1 | Power connector |
2 | Battery power button |
3 | GSM SIM card slot |
4 | Connections for 3 wired zones. See Connecting wired accessories |
5 | Tamper switch |
6 | Microphone |
Connecting wired accessories
Zone 1, Zone 2 and Zone 3 are the EOLR wired zones that support devices
(sensors) with NO (open circuit) and NC (closed circuit) signal with a
response time of 300 ms. Maximum resistance of the area: 11000 Ohms + EOLR
Connect the NC (Normally Closed) devices in series at the top of the loop. The
EOLR resistor must be connected in series with the devices to the last device.
Connect the NO (open circuit) devices in parallel, in the loop.
Wiring diagram
Note: EOLR (End of Line Resistor): If the EOLR resistor is not at the end of the loop, the area will not be properly monitored and the system may not respond to an open circuit in the area.
Home screen
1 | GSM status | Missing SIM card or defective SIM card | |
---|---|---|---|
GPRS- connected to server | |||
RSSI signal level |
The signal level is displayed by bars from 1 to 5 (weak to strong), and the bars are gray if the system is not registered in the GSM network
2
|
WiFi status
| | The system is connected to WiFi. The number of bars indicates the signal
strength.
| The system is connected to the server, if the point is displayed.
3| GSM| | Outgoing SMS
| Outgoing phone call
4| Keyboard status| | Keys locked
5| Power supply| | The system is powered to 230V
| 0~3 bars
The system is powered by the built-in battery. The icon is red when the
battery is discharged.
6| Time| 15:44| Real time
7| Date and day of the week
8| Alarm status| | The system is fully armed
| The system is partially armed
| The system is disarmed
9| Time|
15:44
| Real time
9| Display system status messages| Exit delay
Message “Please exit” + Countdown You have xx seconds to leave the house.
When the time has expired, the alarm system is armed.
9| Display system status messages| Entry delay
Message “Please disarm” + Countdown
You must disarm the system before the entry time expires. If the time has
expired and you have not disarmed, the alarm will sound.
---|---|---
9| Display system status messages| Pairing mode (Sniffer)
Message “Synchronizing” + Countdown
You must activate the wireless accessory before the pairing time expires.
9| Display system status messages| Message “Alarm” or “Panic Alarm“ is
displayed together with the Zone where the alarm was triggered.
Menu
To enter the menu, when you are in the initial interface, press the key √.
Settings
Delay| Exit Delay| Set the exit delay Between 0 ~ 65535 sec.|
Default: 40 sec.
Entry Delay| Set the entry delay Between 0 ~ 65535 sec.| Default: 30
sec.
Siren Duration| Set siren duration Between 0 ~ 65535 sec.| Default: 3
minutes
Switch| Arm Beep| Enable/Disable the beep when arming/disarming(1)|
Default: Enabled
Siren| Enable/Disable the siren sound when an alarm occurs| Default:
Enabled
Switch| Arm SMS| Enable/Disable SMS notification on
arming/disarming| Default: Disabled
---|---|---|---
Keypad lock| Enable/Disable the key lock function (2)| Default: Disabled
Backlight| Enable/Disable illuminated keys(3)| Default: Enabled
Keypad tone| Enable/Disable key sound| Default: Enabled
SOS| Enable/Disable SOS button| Default: Enabled
Delay tick| Enable/Disable countdown sound at entry or exit| Default:
Enabled
Door/Window open warning| Enable/Disable open window/door warning
after arming (4)| Default: Enabled
Human Voice| Enable/Disable voice prompts| Default: Enabled
Password| System| Change the system password(5)| Default: 6666
User| Change the user password(6)| Default: 1234
Language| Chinese, English, German, Russian, Spanish, Polish, Italian,
French, Portuguese, Greek, Romanian (7)| Default: English
Initialization| Return to factory settings. All accessories and
parameters will be deleted.
Reset| The system will restart.
---|---
Phone
1st Phone, 2nd Phone, 3rd Phone, 4th Phone, 5th Phone|
Input the phone number and enable or disable calling or sending an SMS in case of alarm on the respective number
|
Default: null
Log
Alarm log| Displays the alarm history log
Arm log| Displays the history log of arming/disarming the system
Parts
Remote| Add| Pair or delete all remote controls
Delete
Delete All
Detector| Add| Pair, edit or delete all sensors
Edit
Delete All
RFID| Add| Pair or delete all RFID TAGs
Delete
Delete All
Siren Learn| Send a pairing signal towards the wireless siren
EOL Zone
| EOL Zone 1|
Define a name and number of EOLR zones (wired zones)
EOL Zone 2
EOL Zone 3
Alarm Socket| Wireless socket activation on alarm
Socket| Pair a wireless switch/relay: Socket1, Socket2, Socket3,
Socke4, Socket5, Socket6, Socket7, Socket8
---|---
Decoder| Displays the alarm system ID
WiFi
Air Link Configure| WiFi setup (Requires smartphone app)
Unbind| Disconnect the CPU from the server
MAC| Used to display the MAC and IP addresses of the WiFi module
Sofa Configure| WiFi hotspot connection
Record
Record| Audio message recording (sent by calling the preset phone numbers in
case of alarm)
Play| Message playback
Delete| Delete message
Duration| Set message duration, between 0-20 sec.| Default: 20 sec.
Timer
Arm Timer| Set a daily time for automatic arming
Disarm Timer| Set a daily time for automatic disarming
Zone&Sync| Set the time zone
Date&Time| Set time and date
Wi-Fi- Sync| Turn on/off time synchronization using WiFi network information|
Default: On
---|---|---
2G/4G Sync| Turn on/off time synchronization using the GSM network
information| Default: On
Version
Displays the firmware version and MAC address of the WiFi module, the firmware
version and IMEI of the GSM module and the serial number of the central unit.
Footnotes
- Arming beep: When the function is enabled, the system will announce by a sound the arming or disarming operation.
- Key lock: If this function has been enabled, the system will automatically lock the keyboard if no operation is performed for 30 seconds. To activate the keyboard, you must enter the user password.
- Keys backlight: If the function is deactivated, the key backlights turn off after 30 seconds if no operation is performed.
- Open door/window warning: If the function is enabled, the system will generate an warning notification when you open a door or window after the exit time has elapsed.
- System password: used to unlock the keypad and make remote settings via SMS.
- User password: used to unlock the keypad, as a prefix for remote settings via SMS and notification for alarm text.
- Language: the voice prompts and the notification will be in the selected language. After selecting the desired language, the panel will restart.
- Initialization: All customized parameters will return to factory defaults and all paired sensors will be deleted.
Configuration
Power the control unit
Connect the power adapter in the package to the 5V micro USB port and move the
backup battery switch to the “ON” position.
WiFi communication through the integrated module
If your system is configured to report alarms and accept remote control via
the mobile application, the wireless router the alarm system is connected to
must always be on and connected to the Internet.
GSM/4G WiFi communication through the integrated module
If your system is set up to report alarms, receive settings via SMS, or make
voice calls, make sure a SIM card is installed (see image below) and the
control panel is connected to the GSM/4G network. Disable the PIN to the SIM
card before adding it into the unit.
Add and configure phone numbers
You can set up to 5 phone numbers that will receive alarm notifications via
SMS or voice call.
- In the menu go to: Phone -> 1st Phone, 2nd Phone, 3rd Phone, 4th Phone, 5th Phone
- Press the key ↑ to select the first option where you can input the phone number (maximum 18 digits) using the numeric keypad
- Press again the key ↑ to select the second option. Press the key ↓ to choose between On and Off. If you select On, in case of alarm, a voice message will be sent to the respective phone number.
- Press again the key ↑ to select the third option. Press the key ↓ to choose between On and Off. If you select On, in case of alarm, an SMS will be sent to the respective phone number.
- Press √ to confirm.
Add/Delete remote controls
Add new remote control
- In the main menu, select: Parts-> Remote-> Add.
- On the screen, the message Synchronising will show up. The system enters the pairing mode and counts the remaining pairing time (maximum 20 sec.).
- Press a button on the remote control to send a signal to the control panel.
- On the screen, the message Device code has been learnt will show up if the remote control was successfully paired.
Delete remote control
- In the main menu, select: Parts-> Remote->Delete
- Use the keys ↑ and ↓ to reach the remote control that need to be deleted.
- Press √ to confirm.
Delete all remote controls
- In the main menu, select: Parts-> Remote->Delete all
- The total number of learned remote controls is displayed.
- Press √ to confirm.
Add/Delete wireless sensors
Add sensor
- In the main menu, select: Parts->Detector->Add
- Press the key ↑ to select the first option, Name, where you will select the sensor name using the key ↓
- Press again ↑ to select the second option, Mode. Press the key ↓ to choose between:
Active when perimeter arming- usually assigned to sensors or magnetic
contacts on exterior (perimeter) doors and windows. The sensor is active when
the system is fully armed or partially armed.
Inactive when perimeter arming- usually assigned to a sensor (eg motion
sensor) in an interior area (eg living room, hall, bedroom). The sensor
remains inactive if the system is partially armed.
24 hours active- usually assigned to an area that contains an emergency
button, smoke sensor, CO sensors, flood sensors and gas sensors.
To use the sensor as a doorbell, select Doorbell.
To deactivate the sensor, select Close.
-
Press again ↑ to select the third option, where you will select using the key ↓ the number of the zone where the respective sensor will be assigned. 0-89 numbers are available. The zone number must be unique.
-
Press the key √. The message Synchronising appears on the screen.
The system enters pairing mode and counts the remaining pairing time (maximum 20 sec.) -
Trigger the sensor to send a pairing signal towards the control panel.
-
After pairing, the message Learning OK will be displayed.
Edit/Delete a sensor
- In the main menu, select: Parts->Detector->Edit
- Press the key ↑ to select the first option that contains the position on which the sensor to be edited was saved. Press the button ↓ to reach the desired position.
- Press again ↑ to switch between options and the ↓ key to change the values of an option.
Delete all sensors
- In the main menu, select: Parts->Detector->Delete all
- Press the key √ to confirm.
Add/Delete RFID TAGs
Add new TAG
- In the main menu, select: Parts-> RFID-> Add.
- The message Synchronising appears on the screen. The system enters pairing mode and counts down the remaining pairing time (maximum 20 sec.).
- Move the TAG closer to the RFID area marked on the control panel.
- The screen will display Device code has been learnt if the TAG was successfully paired.
Delete TAG
- In the main menu, select: Parts-> RFID->Delete
- Use the keys ↑ and ↓ to reach the position where the TAG to be deleted was saved.
- Press √ to confirm.
Delete all TAGs
- In the main menu, select: Parts-> RFID->Delete all
- The total number of TAGs learned is displayed.
- Press √ to confirm.
Pairing a wireless siren
- Switch the siren to pairing mode (see the siren user manual). Note: The wireless siren is not included in this package. Compatible product: Wireless outdoor siren PNI Safe House HS007
- In the main menu, select: Parts->Siren Learn
- The system sends a signal to the siren. The message Learn signal sent appears on the screen.
- The wireless siren will confirm pairing with an audible or visual signal (see the siren user manual).
Pairing a wireless socket or relay
- In the main menu, select: Parts->Alarm Socket
- Switch the wireless socket/relay to pairing mode (see the socket/relay manual). The wireless socket/relay is not included in this package.
- Press the key ↑ and ↓ one at a time. The system sends twice a signal to the socket/relay. The message Learn signal sent appears on the screen.
- The wireless socket/relay will confirm the pairing. For details, refer to the manual of the wireless socket or relay.
- To test whether the wireless device can be opened and closed, press the ↑ and ↓ keys one at a time.
Note: When an audible alarm is triggered, the wireless socket or relay will remain open until the system is disarmed or the alarm time expires.
Intelligent automation Wireless socket/relay pairing
- In the main menu, select: Parts->Socket. Up to 8 smart sockets or relays can be added.
- Switch the wireless socket/relay to pairing mode (see the socket/relay manual). Note: The wireless socket/relay is not included in this package.
- Press the ↑ key and the ↓ key one at a time. The system sends a signal to the socket/relay twice. The message Learn signal sent appears on the screen.
- The wireless socket/relay will confirm the pairing. For details, refer to the manual of the wireless socket or relay.
- To test whether the wireless device can be opened and closed, press the ↑ “On” key and the ↓ “Off” key.
Note: You can open and close the wireless socket or relay in the Tuya Smart mobile application.
Record messages
Record and playback messages
You can record a voice message (up to 20 sec.) through your alarm system.
If an alarm is triggered, you can receive a voice call with that message on
the preset phone numbers.
- In the main menu, select: Record-> Record
- Speak in a normal tone of voice
- Recording stops automatically after the preset time has elapsed
- The system automatically plays the message
- Press the √ key to save the message
You can playback the recorded message, delete it or change its maximum duration by accessing the options in the Record menu.
Automatic arming/disarming
You can set the daily arming and disarming at certain hours.
- In the main menu, select: Timer-> Arm Timer or Timer-> Disarm Timer
- Press the key ↑ to change the option and the key ↓ to change the setting.
- Press √ to confirm.
SMS configuration
You can configure the alarm system remotely via SMS.
The text of the message differs depending on the command to be sent to the
alarm system.
Send the message to the SIM number installed in the alarm system. You will
receive a confirmation SMS on your phone if the setting was successful.
Note: The examples below use the default system password: 6666.
Set phone number via SMS
Command | Function |
---|---|
51 | 1st phone number |
52 | 2nd phone number |
53 | 3rd phone number |
54 | 4th phone number |
55 | 5th phone number |
Syntax of the message to be sent:
System passwordCommand107xxxxxxx,A,BCommand207xxxxxxx,A,B
The * symbol marks the beginning and end of the syntax and is also used as a
separator between commands.
07xxxxxxxx, A, B
In this string:
07xxxxxxx represents the phone number (up to 18 digits)
A used to enable (1) or disable (0) the voice call in case of alarm
B used to enable (1) or disable (0) SMS notification in case of alarm
Examples:
To set the first phone number 0710123456 and to activate only the SMS
notification in case of alarm and to set the second phone number
0720654321 and to activate only the voice calling, then the SMS
message to be sent to the system will have the form:
6666510710123456,0,1520720654321,1,0
In this Syntax:
- 6666 is the default system (administrator) password
- 51 is the command to set the first phone number
- 0710123456 is the phone number
- 0 the phone call function is disabled
- 1 the SMS function enabled
Query system settings via SMS
First query
Message syntax: *666662
You will receive a message on the phone:
SYSTEM set:
SN: xxxxxx (system serial number)
LANGUAGE: English (system language)
ENGINEER PASSWORD: 6666 (system password)
USER PASSWORD: 1234 (user password)
GSM CSQ: 17
Wi-Fi RSSI: 0
Second query
Message syntax: *666690
You will receive a message on the phone:
SYSTEM set2:
APN: CNMET (Access Point name)
GPRS IP: x.x.x.x:x (server IP and port)
NTP: …
TIME ZONE: +08:00 (time zone)
SERVER: GLOBAL
Query phone numbers via SMS
Message syntax: *666651
You will receive a message on the phone:
PHONE set:
1: 07xxxxxxxx, A, B
2: 07xxxxxxxx, A, B
3: 07xxxxxxxx, A, B
4: 07xxxxxxxx, A, B
5: 07xxxxxxxx, A, B
07xxxxxxxx is the phone number (up to 18 digits)
A it can be 1 or 0 , meaning the voice call in case of alarm
enabled or disabled
B it can be 1 or 0 , meaning the SMS in case of alarm enabled or
disabled
Make a voice call via the alarm system
When you are in the main interface, press the number keys directly to dial the
phone number you want to call.
Press the √ key to confirm.
Press the ↓ key to delete.
Arm/Disarm the alarm system
Total arming
To arm the alarm system, proceed as follows :
- From the remote control: press the key
- Through the control panel: press the key
- By RFID TAG: Move the TAG closer to the RFID area marked on the control panel
- Through the Tuya Smart application: press the Arm key. Details on controlling the alarm system through the application can be found on page 5.
- By SMS command. The syntax of the message to be sent to the system: 1234#1, in which 1234 is the user password and 1 is the arming command. If you have the SMS sending function activated in your phone number in case of arming, you will receive a confirmation message.
Home arming (perimeter arming)
To home arm the alarm system, proceed as follows :
- From the remote control: press the key
- Through the control panel: press the key twice
- Through the Tuya Smart application: press the Home Arm key. Details on controlling the alarm system through the application can be found on page 5.
- By SMS command. The syntax of the message to be sent to the system: 1234#3, where 1234 is the user password and 3 is the home arming command. If you have the SMS sending function activated in your phone number in case of arming, you will receive a confirmation message.
Disarming
To disarm the alarm system, proceed as follows:
- From the remote control: press the key
- Through the control panel: press the key
- By RFID TAG: Move the TAG closer to the RFID area marked on the control panel
- Through the Tuya Smart application: touch the Disarm button. Details on controlling the alarm system through the application can be found on page 5.
- By SMS command. The syntax of the message to be sent to the system: 1234#2, in which 1234 is the user password and 2 is the disarming command. If you have the SMS sending function activated in your phone number in case of arming, you will receive a confirmation message.
Panic alarm
To trigger the alarm manually, proceed as follows :
- From the remote control: press the SOS key
- Through the control panel: press the SOS key
- Through the Tuya Smart application: press the SOS key. Details on controlling the alarm system through the application can be found on page 5.
General information about the system
- When an AC 230V power outage occurs, the system will continue to run on the internal battery for several tens of minutes.
- Low battery: When the built-in battery is low, you will receive a notification on the control panel screen. Connect the included power cord and move the switch to ON to charge the battery.
- Discharged sensor battery: Each wireless sensor added to the system has an internal battery. The system detects the status of the sensor batteries and displays the message “Sensor Low Battery” if the batteries are discharged. Replace the respective sensor batteries.
- Tamper: When a Tamper action has been detected (attempt to manipulate, destroy the control panel), the system generates an alarm.
SMS or voice call notification in case of alarm
When an alarm is triggered or a system problem occurs, an SMS notification or
a voice call will be sent to the phone number that was saved in the system.
After answering the call, you will hear the voice message previously recorded
in the system and you will be vocally notified of the location where the alarm
was triggered.
Next, you will hear the message: “Press 1 to arm, press 2 to disarm, press 3
to monitor, press 4 to speak”.
If you have confirmation that it is a false alarm, press 1 to cancel the
ongoing alarm.
Technical specifications
– Power supply: USB power adapter 230VAC- 5VDC, 1A
– Backup battery: 3.7V/1000mAh Lithium Ion
– Current: <150mA @ normal
– Siren current: <300mA
– Wired siren sound intensity: 100dB
– Built-in siren sound intensity: 80dB
– Radio frequency: 433MHz
– RF transmission power: 10mW
– WiFi frequency: 2.4GHz
– WiFi transmission power: 100mW
– RF code : eV1527
– GSM frequency : 850/900/1800/1900MHz
– Wi-Fi: IEEE802.11b/g/n
– Operating temperature: -26°C ~ +80°C
– Control unit dimensions: 180x115x22 mm
Simplified EU declaration of conformity
SC ONLINESHOP SRL declares that PNI Safe House HS600 Wireless Alarm System
is in accordance with EMC Directive 2014/30/EU and RED Directive 2014/53/EU.
The full text of the EU Declaration of Conformity is available at the
following website:
https://www.mypni.eu/products/8044/download/certifications
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>