UNI-T UTi120MS Infrared Thermal Imaging Camera User Manual
- June 9, 2024
- UNI-T
Table of Contents
UNI-T UTi120MS Infrared Thermal Imaging Camera
Preface
Thank you for purchasing this brand new UTi120Mobile Smart Phone Thermal
Camera. In order to use this product safely and correctly, please read this
manual thoroughly, especially the safety notes.
After reading this manual, it is recommended to keep the manual at an easily
accessible place, preferably close to the device, for future
reference.
Limited Warranty and Liability
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase dale. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination or improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.
Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by using this device.
Specifications
Take photos / videos|
---|---
PiP
(Picture-in- Picture)
| Simultaneous display of mobile phone
camera image and infrared image
High/ low temperature tracking| Real- time tracking of the highest/ lowest
temperature in the thermal image
High / low
temperature alarm
| The temperature is customizable.
Photo editing| Saved photos can be edited.
Video editing is not supported.
Image data interface| USB_UVC (Type- C)
Operating temperature| o- +45°c
Storage temperature| – 2- +6□0 c
Relative humidity| 10 %- 85 %, non – conden sing
Operating altitude| 2000m
Certifications| CE, RoHS, FCC
Accessories
| User manual, Type-C male to female extension cable, Micro USB to Type-C
interface adapter
Drop proof| 2m
Connection
Open the APP. If the device is not detected, the following interface will appear as shown in Figure 1. At this time, users can still enter the “Photos” and “Selling” pages, but other functions are unavailable. Insert the product into a smart phone, a prompt “Open UTi120Mobile to process the UNIT Applicationl Device?” will pop up. Click OK to connect to the device (if users want to connect directly without a prompt next time, check the box below “Always open UTi120Mobile after connecting to the UNIT Application Device” before clicking OK).
The words “Loading … ” and “Calibrating … ” will appear when detecting the device as shown in Figure 2.
Display
The initial slate of the device after startup is shown in Figure 3 below. The palette is Iron Red by default, and the main page is divided into the following sections.
Description
1 Upper temperature limit
2 Temperature distribution slider
3 Lower temperature limit
4 Photos
5 Menu bar
6 PiP
7 Start taking photos/videos/finish taking videos
8 Center point cursor
9 Temperature of the current center point
Photos
After opening the APP, click on Photos (No.4 in Figure 3) to enter the photos/videos interface as shown in Figure 4. and users can view and select these photos/videos.
Select/Cancel (Figure 5)
Click “Select” and then click a photo/video, the photo/video will be selected,
and there will be a checked checkbox on the corresponding thumbnail. Click
“Cancel”, and the checkbox will disappear.
When a photo/video is selected, ii can be shared or deleted, and the icons are
Share and Delete [ii respectively.
View (Figure 6)
Click on a photo to enter the viewing interface, and users can perform
functions such as Share/PiP/Delete/Blending/Edit. Click “Delete”, and it will
prompt “Delete this file?” Select “YES” to delete the photo and return to the
photo interface.
Click on a video to enter the viewing interface, and users can perform functions such as Play/Share/Delete. Click on the screen, and the icon – will appear. Users can Pause/Fast Forward/Rewind the video by using this icon or dragging the progress bar below.
PiP/Blending (Figure 8)
Click the icon Iii, a small PiP window will appear in the lower right corner.
Users can also click on the icon lill to check the blending situation, and
drag the upper slider to adjust the blending ratio of visible light and
infrared light.
Clicking the PiP and blending icons can turn off these two functions, and a prompt “No visible light” will pop up.
Remarks : When using a Type-C extension cable to connect to the product, the relative distance between the visible light camera and the product camera is unfixed and the blending effect is not good. Therefore, it is not recommended to perform the blending function when using a Type-C extension cable.
Edit
Click “Edit” in the photo viewing interface to enter the editing interface.
Users can edit the current photo, and click “Cancel” to cancel the previous
operation. After saving the editing operation, enter the editing interface
again and click “Restore” in the upper right corner to restore the photo to
its original state.
The infrared thermal imaging photos taken by UTi120Mobile App can be edited
while viewing.
The specific editing operations are as follows:
- Rotate the photo: click the icon 1!11 to change the photo direction.
- Add an analysis object: click the icon 11.il to display the following interface. These analysis objects can be moved/added/deleted.
Visible Light Blending
When users click the icon t;i , a slider for adjusting blending will appear
at the top. Dragging the slider can adjust the blending ratio of visible light
and infrared light. Click the icon 1111 , and the blending icon , will appear.
Drag the icon, and it will display the blending situation of the relevant
position. Click 1111 again, the blending icon will disappear.
Add Analysis Objects
Click the icon 1,11 to enter the interface for adding analysis objects, as shown in the figure below. Users can add/move/delete analysis objects (point/line/area), and only six objects can exist at the same lime. After adding an analysis object and taking a photo, the added object can still be deleted.
Description
1 Add a line
2 Add a rectangle
3 Add a circle
4 Add a point
5 Delete the selected analysis object
6 Temperature analysis area
Point
Clicking the icon 13 can add a point temperature analysis object and expand a
semi-transparent information bar on the right side of the interface to display
the temperature information of the analysis objects. Click once to add one
point. If users drag a point to change its position, the temperature
information of the point will be updated synchronously, and up to 6 point
analysis objects can be added.
Line
Clicking the icon a can add a line temperature analysis object and expand a
semi-transparent information bar on the right side of the interface to display
the temperature information of the analysis objects. Click once to add one
line. If users drag a line to change its position, the temperature information
of the line will be updated synchronously, and up to 6 line analysis objects
can be added.
Area
Clicking the icon l!I can add a rectangle temperature analysis object and
expand a semi-transparent information bar on the right side of the interface
lo display the temperature information of the analysis objects. Click once to
add one rectangle. If users drag a rectangle to change its position, the
temperature information of the rectangle will be updated synchronously, and up
to 6 rectangle analysis objects can be added. Clicking the icon Ii can add a
circle temperature analysis object and expand a semi-transparent information
bar on the right side of the interface to display the temperature information
of the analysis objects. Click once to add one circle. If users drag a circle
to change its position, the temperature information of the circle will be
updated synchronously, and up to 6 circle analysis objects can be added.
Delete Selected Analysis Objects
Clicking the icon Iii! can delete the selected temperature analysis object.
Palette (Figure 9)
In the main interface, click the icon ill to open the palette selection
interface, as shown in the figure below. This APP provides Iron Red, Rainbow,
Gray Scale, Red Hot, Black While, Lava, High-Contrast Rainbow palettes for
users to choose according to different scenes or preferences.
Setting (Figure 10)
Click the icon to enter the setting interface, as shown in the figure below. In the setting interface, users can perform functions such as selecting language/temperature unit temperature mark, setting high and low temperature alarm/emissivity/measurement distance, and viewing version information.
Language
Users can select the language according to their needs. The APP currently
supports Chinese (default) and English.
Temperature Unit
The default temperature unit is Celsius (°C), and users can switch to
Fahrenheit (°F) as needed.
Temperature Mark
Users can set Max Temp Mark, Min Temp Mark and Center Mark. After turning on
these marks, the main interface will display the corresponding marks (Max Temp
Mark: red, Min Temp Mark: green, Center Mark: a central cross cursor). If the
marks are not turned on, the main interface will only display the temperature
distribution slider, as shown in the figure.
Temperature Alarm
Users can set Temperature Alarm Max and Temperature Alarm Min. After setting,
when the temperature exceeds the Temperature Alarm Max, a red triangle will
appear. When the temperature is lower than the Temperature Alarm Min, a green
inverted triangle will appear.
If the Temperature Alarm is turned on, but the corresponding temperature value is not set, a prompt “The temperature setting is wrong. Please check!” will pop up.
Emissivity
The default value of emissivity is 0.95. Users can adjust the temperature
measurement parameters according to the different measured objects to improve
the measurement accuracy.
Distance
The default distance is 0.6m. Users can adjust it according to their
requirements.
Help
Open the product instruction manual.
About
It includes the APP Version and the Model Version.
Switch PhotoNideo Function
Slide the camera button le!Uright to switch between taking photos/ videos.
Both photos and videos will be automatically saved in the Photo.
Start/End Taking PhotosNideos
Slide the camera button leturight to enter the recording mode. Click the
recording button to start recording, and the recording duration will be
displayed on the top. Click the button again to end the recording.
PiP
Click the icon on the main interface, the APP will open the phone camera and
display a small PiP window. Click the icon again to cancel the PiP. When
double-clicking anywhere in the small window, the visible light and infrared
light display windows will be interchanged, and double -clicking the small
window again will restore the state.
Switch Camera
Click the icon to switch the front/rear camera of the mobile phone, and the
infrared light image will be mirrored. The front and rear visible light
cameras of the mobile phone can be switched at the same time, and the infrared
thermal image can be mirrored.
Auto/Manual Call Shutter
- The App will automatically call the shutter according to the temperature measurement needs when operating;
- Clicking the cross cursor can manually call the shutter.
Notes
- The App will automatically call the shutter according to the temperature measurement needs when operating;
- Do not use soluble liquids on the device, as this may cause device damage.
- When using the device, please try to keep it stable and avoid violent shaking.
- Please do not violently disassemble the product to avoid irreversible damage.
- Please avoid hard objects scratching the device lens.
- Please do not point the product lens at high-intensity energy sources (including the sun, laser emission equipment and the reflection sources of these equipment), otherwise it may affect the measurement accuracy, and damage the infrared detector of the product.
- Please put the product into the plastic box when it is not used.
FCC Compliance statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
UNI-T:
UNI-TREND TECHNDLDGIV (CHINA) CD., LTD.
No.6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City, Guangdong Province, China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>