KACO 87.0 TL3 String Inverters for Commercial and Industrial PV User Guide

June 9, 2024
KACO

Quickstart Guide
KACO blueplanet

87.0 TL3 String Inverters for Commercial and Industrial PV

87.0 TL3 110 TL3 150 TL3
92.0 TL3 125 TL3 155 TL3
105 TL3 137 TL3 165 TL3

www.kaco-newenergy.com

Danger!
Danger to life due to electric shock and electrical discharge.
Dangerous voltages are present in the inverter.

  • Only allow work on the device to be carried out by a qualified electrician.
  • The device is only permitted to be opened or serviced by a qualified electrician.
  • Always disconnect the device from the power supply during installation, maintenance and repairs and secure it against being switched on again.
  • Do not connect or disconnect DC cables to or from the unit during operation to avoid dangerous electric arcs.

KACO 87.0 TL3 String Inverters for Commercial and Industrial PV -
fig

Scope of delivery

KACO 87.0 TL3 String Inverters for Commercial and Industrial PV - qr
1

https://kaco-newenergy.com/de/service/mykacocom-kundenportal/

Mounting kit Quantity
Ziplock bag 100×150 1
Label 70×35 1
Washer M10 DIN 125 10
Hexagon nut M10 DIN 934 5
Hexagon head  screw M10x25 DIN933 5
CON-PIN-BTB 2POL 1ROW ANG 320V 8A P5,08 1
CON-PIN-BTB 3POL 1ROW ANG 320V 8A P5,08 1
CON-P SPRING 6-POL 1,5qmm 160V 8A RM3,5 1
CON-PLUG SPRING 2POL 1,5q 160V 8A RM3,5 1
Fischer dowel S12 4
Hexagon wood screw 8×8 DIN571 4
Spring washer M10 DIN128A 5
Cable tie 100×2,5 PA 6.6 nature 3
Combi-Screw DIN6900-3Z4-1TX8.8 1

Accessories

Accessories KACO order no.
Bending box 1001917
Kit input plate AC Inverter 1001882 (double row) / 1001906 (M63/32)
Kit Overvoltage protection AC Inverter 1001884
Kit Overvoltage protection DC Inverter 1001885
Kit Surge Protection LAN Inverter 1001886
Kit Overvoltage Protection RS485 Inverter 1001887
PID Connection Set 1001888
WLAN adapter Digitus 150N micro 3013222
Spare fuses (10x85mm 1500V 5A PID) 1001883
KACO blueplanet DC-Breaker 1001860

 Overview

KACO 87.0 TL3 String Inverters for Commercial and Industrial PV - fig
3

Mounting

KACO 87.0 TL3 String Inverters for Commercial and Industrial PV -
fig5

 Installation

5.1 DC connection

KACO 87.0 TL3 String Inverters for Commercial and Industrial PV -
fig6KACO 87.0 TL3 String
Inverters for Commercial and Industrial PV - fig10

KACO 87.0 TL3 String Inverters for Commercial and Industrial PV -
fig8

PE connection

Status LED

https://kaco-newenergy.com/de/service/mykacocom-kundenportal/

Communication variants

  1. Communication board

  2. USB socket

  3. SD slot

  4. Ethernet for network connection DHCP

  5. RS485 – standard

  6. DIP switch – Activate terminating resistor (2x)
    DIP switch must be activated if KACO inverter or String Combiner is terminal device (120 mOhm).
    Upper DIP switch: to String Combiner
    Lower DIP switch: to inverter.

  7. INV OFF – Connection for remote control devices – 24V(+/-20%) /1A (min. 15mA)

  8. ERR – Connection for external mains protection component (fault signal relay)

  9. Ethernet – Only for commissioning via static IP

  10. RS485 – Connection for string combiner (CON 200)

Initial commissioning

KACO 87.0 TL3 String Inverters for Commercial and Industrial PV -
fig15

Group update / Group parameterization

 Registration Portal

www.kaco-newenergy.com

 System overview

              KACO 87.0 TL3 String Inverters for Commercial and Industrial
PV - fig 5

Werner-von-Siemens-Allee 1 | 74172 Neckarsulm | Germany
Tel. +49 7132 896-0
info@kaco-newenergy.de
www.kaco-newenergy.de

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals