CAUTION! — READ THIS FIRST — IMPORTANT SAFETY INSTRUCTIONS
WARNING
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Commercial installation, service, and maintenance of luminaires should be performed by a qualified licensed electrician.
- For the installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician and check your local electrical code.
- To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during installation.
WARNING
- Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
- Turn off the power when you perform any maintenance.
- Verify that the supply voltage is correct by comparing it with the luminaire label information.
- All wiring connections should be capped with UL-approved wire connectors.
CAUTION
- Avoid direct eye exposure to the light source while it is on.
- Account for small parts and destroy packing material, as these may be hazardous to children.
- Risk of burn. Disconnect power and allow the fixture to cool before handling..
NOTICE: Green ground screw provided in the proper location. Do not relocate.
NOTICE: Minimum 90° supply conductors.
NOTICE: Specifications and dimensions are subject to change without notice.
NOTICE: Suitable for Dry or Damp locations.
General Wiring Diagram
SURFACE MOUNTING
STEP 1
Remove the lens from the housing by pressing the provided suction cup to the
lens near one end of the luminaire. Pull up on the suction cup to detach the
lens from the luminaire housing.
STEP 2 — (FOR LSCS VERSIONS ONLY)
Different lumen and correlated color temperature levels can be achieved by
setting the switch on the driver cover to different positions:
25W = 3000 lm ; 30W = 3500 lm; 35W = 4000lm
Field-Adjustable Wattage & CCT
STEP 3
Place the luminaire on the junction box and pencil the four hole positions
onto the ceiling. Put the luminaire aside and drill the four holes. Insert an
anchoring bolt (not included) into each hole. Screw the four mounting screws
into each anchoring bolt, then connect the AC wires.
STEP 4
Install the lens, starting at one end of the housing. Insert lens slot onto
the edge of the housing. Carefully squeeze the lens to engage the opposite
side with housing. Continue this action down the length of the lens until
fully installed onto the housing.
Surface Mounting, Expanded View
© 2021 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications
are subject to change without notice.
701 Millennium Blvd
Greenville, SC 29607 / Tel 864.678.1000
Website www.columbialighting.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>