UGREEN GS600 680Wh PowerRoam Portable Power Station User Manual

June 9, 2024
UGREEN

UGREEN GS600 680Wh PowerRoam Portable Power Station User Manual

Product Overview

Product Details

  1. Flashlight 0 LCD Display
  2. Car Charging Output Port
  3. Ventilation Holes
  4. Flashlight Power Button
  5. loT Button/ loT Indicator
  6. USB-C Output Ports X 2
  7. Main Power Button/Power Indicator
  8. USB-A Output Ports X 2
  9. DC Power Button/DC Output Indicator ® DC5521 Output Ports X 2 O AC Power Button/AC Output Indicator O AC Output Outlets X 5 O Overcharge Protection Switch 0 AC Input Outlet (Utility Power) O DC Input Port (Solar/Car Charging) 0 Protective Earth Screw 0 Ventilation Holes

LCD Displ.ly

Specifications

Recharging Your Power Station

Safety Precautions

Before chorglni, plea,e make sure the powerslatlon Is grourdooeffectlve~ •r>d rellabli
· Fl, .. , use on oiginol □ r IOlfety-<>ertifi ,d power cord that meet, tli e ch argin g sp<>:ilic,tion, of thi, prod uct.
· When d,ar~nl’,, moke ,u re ttiat the product is well”‘Jentilat<d and froe of oombusti, le>.

Important Note

  • Please fully charge this power station before using it for the first time.
  • In order to ensure the safety of charging, if the input current exceeds the overcurrent protection value during charging, the product will automatically trigger the overcurrent protection function, and the Overcharge Protection switch will pop up. After the overcurrent is eliminated, press the button again to resume charging.
  • If the product shows a low battery, please recharge promptly, otherwise it may become unusable.

AC Recharging

Recharge with PowerZip Fast Charging Max 600W Input Power

Solar Rechargin1

Car charging

To charge power station via vehicle cigarette lighter port: 1. Please start the vehicle before using car charging cable to recharge the power station. This is to prevent vehicle failure to start due to insufficient battery. 2. Please ensure cigarette lighter port and the car charging cable are properly connected.

Flashlight

In the standby state, you can switch between the 5 states of “Low Light—> High Light—) Flash SOS —› Off” by pressing the “LIGHT” button.

Powering Your Devices

Power On/Power Off

Tips: In the Power-On state, if not used within 3 minutes, the display will automatically turn off. Press any button to turn LCD display on.

AC Output

car Charging: Output/ DC5S21 Output

USB Output

App User Guide

To control the power station via mobile device, download the “UGREEN” App:

Scan the QR code to download the “UGREEN” App
Tips: You can also search for “UGREEN” App via Apple Store or the Google Play Store.

Features & Operating Modes

U-Turbo When activating the U-Turbo Mode, AC output ports of the power station can support devices with power ratings of up to 1500W. Tips: • For safer charging, U-Turbo is temporarily unavailable when the power station is charging while charging other devices. • U-Turbo is enabled by default. You can disable it using the “UGREEN” App. • If the U-Turbo Mode is on, it is recommended to connect only one device to the AC output port to avoid abnormal use of the power station. • The AC output port can support up to 1500W of heating devices such as hair dryers, electric kettles, etc., but the U-Turbo Mode is not applicable for all electrical appliances. Inductive and high-power devices such as air conditioners, coffee machines, and clothes dryers are not recommended.

Uninterrupted Power Supply (UPS)

Do not use UPS features in situations or with devices that require extreme reliability and/or security. Examples include but are not limited to: • Use with life-saving medical equipment like medical ventilators;

  • Use in situations or environments that may cause severe bodily harm/injury (such as on airplanes, ships, railways, elevators, etc.);
  • Use with data storage devices (such as servers, hard drives, etc.).

This power station is not intended for use in any high-risk activities, such as activities where equipment failure can directly result in death, personal injury, substantial property damage, or activities that affect the operation of medical or similar equipment. UGREEN expressly disclaims any express or implied warranties of suitability for high-risk activities. Any such use is a misuse of the power station.

Power Reduction Mode

For safe use, the Power Reduction Mode of the power station will be automatically turned on in the following 4 states: 1. Low temperature 2. High temperature 3. Low battery charging 4. Trickle charging (The Power Reduction Mode icon on the LCD display illuminates to indicate that the function is on.)

Openting Mode

Factory Reset To perform a factory reset, ensure the power station is not connected to any other device/appliances/etc. Press and hold the AC Power Button and the DC Power Button simultaneously for 10 seconds to restore the power station to factory settings.
Note: This operation will clear all network configuration data, function settings, etc. saved by the power station. Perform reset with caution.

FAQs

Ql: What devices can be connected to the AC Output Port of the power station?
Al: The rated power of the AC output port of this power station is 600W, which can power most electronics, but it is recommended that you confirm the power of the device before use and ensure that the sum of the power of all load devices is less than the rated power. When turning on the U-Turbo function, AC output port of the power station can support heating devices with a rated power of up to 1500W. But the function is not suitable for all devices. Inductive and high-power devices such as air conditioners, coffee machines, and clothes dryers are not recommended.
Q2: Can I recharge the power station while charging connected devices?
A2: yes. It is not recommended to power high-power devices when using this feature.
Q3: How do I know how long the power station can power the device?
A3: After a device is connected, the estimated remaining discharge time for the power station will be shown on the display. This is calculated based on the actual power of the connected device and the remaining battery level of the power station. If the actual power of the connected device is high, the remaining power is low, the power supply time is short.
Q4: Is there a fan turning sound during use?
A4: This sound is largely caused by the cooling fan inside the power station, which is normal. For safe charging, the fan will work during charging but you can reduce this sound by turning on [Quiet Mode] in the “UGREEN” App [Settings].
Q5: Why does the power station run out of battery even when no device is connected?
A5: When the AC Output Outlets are on, even if no device is connected, there will be a certain amount of no-load power consumption. To avoid this, please ensure the AC Output Outlets are turned off when not in use to conserve battery

l

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

UGREEN User Manuals

Related Manuals