syride SYS Alti V3 Extra Light Instrument User Guide
- June 10, 2024
- syride
Table of Contents
- Setup the SYS PC Tool
- Place the instrument
- Recharging the battery
- Configure your device
- Advanced configuration
- Customize your screens
- Screens when flying
- Flight detection and altitude setup
- Display and delete a flight
- Warnings and reset
- Transfer your flights
- Parameters
- Suggestion of use
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
syride SYS Alti V3 Extra Light Instrument
Foreword
Welcome in the community of Syriders ! Your SYS’Alti is an extra light
instrument with the most recent technologies, which will able you to improve
yourself and monitor your improvements.
You will also be able to build a unique and highly detailed online flight
book. Your practice of paragliding is going to take a new dimension with the
SYS’Alti !
As a member of the community, you will be a key player in the evolution and continuous improvement if the instrument. Sensors inside the SYS’Alti allows the development of future features. We encourage you to share your suggestions for your greater satisfaction.
Syride whishes you beautiful flights
Setup the SYS PC Tool
- Download the lastest version of the SYS PC Tool by checking the following website : http://www.syride.com/en/software
- Follow the instructions to install it on your computer.
- Once installed, an icon shows in the task bar. It detects when your instrument is connected.
- The software will automatically start with your operating system.
Place the instrument
-
Syride suggests to place your instrument on the risers. 2 velcros ables you to place it on any existing riser. Take care not to « lock » your rope or pulley accelerator. This position ables you to manipulate the instrument while flying without releasing the brakes.
We recommend you to insert a protection between the velcro and your riser in order to avoid the abrasion of it.
-
Velcros also allow placing the instrument on a cockpit in thigh (with extension) or on the wrist.
-
You can secure your instrument by using the strap provided for this purpose.
Recharging the battery
-
Simply connect your instrument’s USB to a computer.
-
Your instrument will display “Charging…” and the percentage of charge. To complete, a charge requires 2 hours.
-
Disconnect USB to stop the charge. Your instrument has a Li-ion battery, which has no memory effect.
-
When your instrument will start the battery icon needs 10 seconds to be stable.
Configure your device
-
Push the central button to start your instrument.
-
Go to screen #5 with left and right buttons, and confirm by clicking on central button. The number of the screen is displayed on the top right of it.
-
The first screen shows some informations about your instrument.
-
Next screen ables you to setup the sound volume.
-
The 2 next screens ables you to setup rising and falling threshold of the vario.
-
You can turn ON or OFF the backlight of your instrument on the next screen.
Warning : backlight reduces the instrument’s autonomy.
-
Last screen is to go back to main screen (#1)
Advanced configuration
Connect your device to a computer with the SYS PC Tool, you get access to advanced setup. You can :
- Adjust the security alarm based on the G-meter.
- Modify the filtering time (integration) of the vario.
- Choose the units and the language of your instrument.
- Change any setup that is changeable inside the instrument.
An explanation of those functions is explained here: https://www.syride.com/en/support
For this :
- Turn-on the instrument and connect it to your computer
- From SYS PC Tool, click on “configure my instrument” icon.
- Change whatever you want.
- Click on Send parameters.
Customize your screens
With SYS’Alti, you can fully customize screens 1 and 2!
To customize your screen ( tutorial video https://www.youtube.com/watch?v=D3lfZWiS13M) :
- Go to : http://www.syride.com/en/ssctool/Alti
- Customize your screen by selecting an item with its size and unit, and then drag and drop it to the screen.
- Download the config file to your computer.
- Turn-on your instrument, and connect it to your computer with USB.
- On SYS PC Tool, click on “Send a file to my Instrument” icon.
- Select the config file you just downloaded before and disconnect your instrument, done.
Screens when flying
-
Screens #1 and #2 shows the informations you previously choosed.
-
Pressing the central button will turn OFF and ON the sound of the vario. This is use full when you need to concentrate on a transition or when landing.
-
Screen #3 displays global information’s concerning your flight. From top to bottom, these information’s are :
o Top altitude
o Min altitude
o Top vario
o Min vario
Flight detection and altitude setup
-
The plane icon on the top left of the screen indicates wether a flight is beeing recorded or not. The vario automatically detects when you’re flying, based on the vario.
-
Pressing the central button on screen #3 ables you to setup the current altitude. Press left and right to select the digit you want to change, and central button to change it. Select the unit digit and press the central button to validate the altitude.
Display and delete a flight
- Go to screen #4 and press the central button to enter the flights list.
- You will see here every recorded flights, with some informations about this flight.
- To delete a flight, press the central button and confirm your action when you’re asked to.
Warnings and reset
If this happens, be sure the instrument’s memory is not full, and check the battery is charged enough.
To protect from flights corruption, your instrument will automatically stop
recording the flight if the battery is too low, or if memory is almost full.
This is indicated when the plane icon on the top left of the screen is
blinking with a cross over it
If the G-Meter exceeds the value selected in advanced parameters (2.5g is the
default value), a highly noisy sound will activate (even if the sound is
turned-off).
If ever your instrument would be stuck (unresponsive to buttons), plug the device to your computer with the USB cable and press the reset button with a needle in the hole on the back of the instrument (keeping the USB plugged).
Transfer your flights
-
Be sure you’ve installed the SYS-PC-Tool software on your computer (https://www.syride.com/en/software)
-
Turn on and connect your instrument with the USB cable.
-
Click on Account configuration icon.
-
The IGC/GPX and KML files are systematically duplicated on your computer.
To use the advanced flight analyzer on syride.com, you must enter your email and password of your Syride account (create one on http://www.syride.com ) Make sure “Use the advanced logbook from Syride.com” is selected to upload your flights and click “OK”.
-
Press the “Download recorded flights” icon, and your flights will be sent from the instrument to your computer and the online flight book.
You can have access to the files on your computer by clicking on File/open local directory -
Go to your profile on the Syride website to visualize your flight (altitude, vario, gmeter, flight time, gain, …)
-
If you want, you can edit some informations about your flight (flight name, wing, flight type, etc..) in order to generate detailed statistics.
Parameters
Here is a list of parameters preprogrammed in your instrument in order to improve its use and autonomy
- Your instrument will turn off if idle – without pressing any keys – for more 20 minutes.
- The SYS’Alti is capable of tracking up to 150h of flight. The maximum number of flights is 30. Then you must transfer or delete flights to record a new one. Note that flights data are automatically deleted from the device upon transfer onto the website.
- Autonomy exceeds 100h of flight.
- The date and time are synchronized with the date and time of your computer.
- Flights less than a minute will be automatically deleted.
- When recording a flight, if the vario is around 0 for more than 2 minutes , then the instrument stops recording.
- By default, the G-force alarm is set to +2.5g and is activated.
Suggestion of use
- Use the strap to secure your instrument while flying.
- If the SYS’Alti is very hot and you fly in very cold air, fog can appear on the screen. It will dissipate within minutes.
- Only use the backlight if required. Otherwise the autonomy will decrease significantly.
- A Factory Reset from SYS PC Tool (Settings icon Repair) allows you to get your instrument back to default state (every recorded flight will be deleted).
- When you connect your instrument to a USB charger, the battery will start charging, even if the instrument is turned-off.
- Feel free to customize your screens thanks to the SSCTool : http://www.syride.com/en/ssctool/Alti
Notes
Important : Safety Notices and Warnings
Precautions of use for the SYS’Alti
Never leave your SYS’Alti unattended Take care of your equipment by cleaning
with a soft cloth regularly. Do not open the product, the screws are tight
with a certain degree which guarantees the seal of the unit. This action would
cancel your guarantee. If water were introduced by inadvertency into your SYS,
open the USB cache to air it and wait until it is dry before lighting it. Do
not expose your device to too high or too low temperatures, which risk
damaging it for good. Avoid leaving it in full sun as an ornement, or putting
it in the freezer! The soaring in the Antarctic is not guaranteed!!
Ensure that the product is well in position before taking off. Syride cannot
be held responsible for the loss of the product during the flight (takeoff
included).
We give great importance to constantly improve the treatment results of
sessions. We can provide an estimate of the indicators. If your results are
not consistent with reality, please let us know so we can improve our data
processing.
Battery
This product uses a lithium-ion battery. Do not expose to temperatures above
50 ° C (120 ° F). The SYS tells the user if it detects a temperature above 50
° C (120 ° F) when in function. Risk of fire, explosion or burning.
If leakage and contact with liquid leaking from the battery, clean thoroughly
with water and seek medical advice immediately. For safety reasons and to
extend battery life, charging can be done in an ambient temperature range.
Temperatures: Standard operation: 0 ° C (32 ° F) to +45 ° C (113 ° F) short-
term storage: -20 ° C (-4 ° F) at 60 ° C (140 ° F) Storage long term – 20 ° C
(-4 ° F) at 25 ° C (77 ° F).
Do not check out, or do not attempt to remove the battery, which is not user
replaceable. If battery problem, please contact Syride support.
Notice to users regarding collection and disposal of batteries and electrical
and electronic equipment.
LITHIUM-ION BATTERY AND ELECTRONIC CIRCUIT IN THIS PRODUCT CAN NOT BE ADDED TO
THE HOUSEHOLD WASTE. To allow proper recycling, please bring it to a
collection point for. Directive 2002/96/EC applies within the European Union.
For the procedure applicable in countries outside the European Union, please
check with local authorities
DO NOT ATTEMPT RECHARGING THE DEVICE WITH A DIFFERENT USB CORD THAN THE ONE
PROVIDED. RATING : 5VDC 500mA.
CE Mark
This product meets the requirements of the CE mark as part of a residential,
commercial or light industrial.
About this document
The greatest care was taken in the preparation of this document. However, due
to the commercial development of the product, some information may not be
quite up to date. The information in this document is subject to change
without notice. Syride not responsible for any omissions or technical or
editorial errors in this manual, in the event of incidental or consequential
damages resulting from the content or use of this
References
- Apache2 Debian Default Page: It works
- Syride
- Syride
- Syride
- Syride - Software
- Syride - Ssctool
- Syride - Software
- Syride - Ssctool
- Syride - Logiciel
- Syride - Ssctool
- Syride - Software
- Syride - Support
- Syride - Registrieren
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>