Product Information: Vardo & Huxton Timber Suites Pryzm 750 & 1000

The Vardo & Huxton Timber Suites Pryzm 750 & 1000 are designed to provide a realistic flame effect and heat output in a timber wall mounted or floor standing fireplace. The suites come with logs, pre-installed fire, remote control, and optional plinth for the Vardo suites. The suites are available in different sizes and have a visible flame area ranging from W748 x H340 to W998 X  340 mm. The suites are patent pending UK Registered Design and were last updated in Nov 2020.

Technical Specifications

The technical specifications of the Vardo & Huxton Timber Suites Pryzm 750 & 1000 are as follows:

  • Fire/Surround: Logs Timber Wall mounted & floor standing: with optional plinth
  • Visible Flame Area (mm): W998 X H340 (for PRYZM 5D 1000) and W748 x H340 (for PRYZM 5D 750)
  • Dimensions: A – 1320mm, 1220mm, 1070mm, 1154mm (for VARDO PRYZM 5D 1000, VARDO PRYZM 5D 750, VARDO PRYZM 5D 750, and HUXTON PRYZM 5D 1000 respectively); B – 810 / 609 mm; C – 277mm; D -1450mm, 1350mm, 1200mm, 1284mm, or 1034mm (depending on the model)

What’s in the Box

The following items are included in the box:

  • Installation Booklet x2
  • Pre-installed Fire (750 or 1000)
  • Mantle Hooks (x2)
  • Screws (x2)
  • Batteries (x2) – AAA
  • Logs (4 Logs Located under the surround or in the leg of surround depending on model)
  • Remote control (Timber only)
  • Where applicable Timber Plinth supplied separately
  • Cams, Pins and Dowels (x7 or x4 depending on the model)

Product Usage Instructions: Installation – Timber

Follow the instructions below to install the Vardo & Huxton Timber Suites Pryzm 750 & 1000:

  1. This is a 2 adult person lift. Do not attempt to lift from the centre of the top panel, lift from under the hearth and underside of the trim as shown in Diagram 1.
  2. Fit Wall Brackets:
  3. Unpack your new suite and remove the rear wall mount bracket which has been screwed to the rear of the fire for transit. Discard the screws.
  4. Decide whether the suite will be floor standing with the optional plinth (Vardo suites Only) or wall mounted, and position the wall mount bracket accordingly. If the suite is planned to be floor standing, position the wall mount bracket 205mm from the floor as indicated in Diagram 2. If the suite is planned to be wall mounted, position the wall mount bracket at the desired height on the wall. Use a spirit level to mark a line equal to the length of the wall mount bracket and mark the appropriate screw fixing points. Screw the wall mount bracket securely to the wall using the marked positions with the correct fixing for your wall material. We advise a minimum of 6-off fixings must be used (see `Important Note’ on page 7).
  5. Hang the fire:
  6. Carefully lift the suite and position the pre installed angle brackets over the mantel hook brackets as shown in Diagram 3.
  7. Lower the suite down to rest on the wall mount bracket. Route the fire power cable correctly as indicated in Diagram 4, confirming the cable is not crushed or damaged on installation.

Technical Specification

PRYZM 1000 Vardo and Huxton Timber Suites
Instructions-fig-1

What’s in the box(s) **

PRYZM 1000 Vardo and Huxton Timber Suites
Instructions-fig-2**

Wall Bracket – Suite support bracket (x1) Attached to the back of the firePRYZM 1000 Vardo and Huxton Timber Suites Instructions-
fig-3

Installation – Timber

This is a 2 adult person lift.
Do not attempt to lift from the centre of the top panel, lift from under the hearth and underside of the trim as shown below.

  1. Remove Rear Bracket
    Unpack your new suite and remove the rear wall mount bracket which has been screwed to the rear of the fire for transit. See Diagram 1.
    Note: Please discard the screws

  2. Fit Wall Brackets
    The first step to installation will be the fitment of the wall mount bracket in the desired position in the room. Dependant on the model purchased, decide whether the suite will be floor standing with the optional plinth (Vardo suites Only) or wall mounted. If the suite is planned to be floor standing (with the plinth positioned below the suite) the wall mount bracket must be positioned 205mm from the floor as indicated in Diagram 2. Alternatively if the suite is planned to be positioned as a wall mounted model the wall mount bracket may be positioned at the desired height on the wall. Using a spirit level mark a line equal to the length of the wall mount bracket at either 205mm (for floor standing) or the desired base position of the wall mounted suite. Position the wall mount bracket level on the line and mark the appropriate screw fixing points. We advise a minimum of 6-off fixings must be used (see ‘Important Note’ on page 7). Screw the wall mount bracket securely to the wall using the marked positions, with the correct fixing for your wall material. PRYZM 1000 Vardo and Huxton Timber Suites Instructions-
fig-6

  3. Measure from the underside of the hearth to the bottom of the L- bracket fitted on either side of the fire surround and make a note of this dimension. X detailed on Diagram 3.

  4. Measure the internal distance between the surround body and make a note of this dimension. Y detailed on Diagram 3.

  5. Working from the centre of the wall bracket- Mark the fixing position of the mantel hooks. X – 28mm and (Y ÷ 2) -10mm, at either side of the brackets. See Diagram 2.

  6. Finally fix the mantel hooks securely in position as indicated in Diagram 2 with the correct fixings for your wall material
    (fixings not supplied). See ‘Important Note’ on page 7.

  7. Fit Wall Brackets
    The first step to installation will be the fitment of the wall mount bracket in the desired position in the room. Dependant on the model purchased, decide whether the suite will be floor standing with the optional plinth (Vardo suites Only) or wall mounted. If the suite is planned to be floor standing (with the plinth positioned below the suite) the wall mount bracket must be positioned 205mm from the floor as indicated in Diagram 2. Alternatively if the suite is planned to be positioned as a wall mounted model the wall mount bracket may be positioned at the desired height on the wall. Using a spirit level mark a line equal to the length of the wall mount bracket at either 205mm (for floor standing) or the desired base position of the wall mounted suite. Position the wall mount bracket level on the line and mark the appropriate screw fixing points. We advise a minimum of 6-off fixings must be used (see ‘Important Note’ on page 7). Screw the wall mount bracket securely to the wall using the marked positions, with the correct fixing for your wall material.

Installation – Timber

PRYZM 1000 Vardo and Huxton Timber Suites
Instructions-fig-7

Note: Mantel hooks must be fitted for both floor standing and wall mounted models.

6. Measure from the underside of the hearth to the bottom of the L- bracket fitted on either side of the fire surround and make a note of this dimension. X detailed on Diagram 3.
7. Measure the internal distance between the surround body and make a note of this dimension. Y detailed on Diagram 3.
8. Working from the centre of the wall bracket- Mark the fixing position of the mantel hooks. X – 28mm and (Y ÷ 2) -10mm, at either side of the brackets. See Diagram 2.
9. Finally fix the mantel hooks securely in position as indicated in Diagram 2 with the correct fixings for your wall material  

(fixings not supplied). See ‘Important Note’ on page 7.

  1. Hang the fire
    Carefully lift the suite and position the pre installed angle brackets, over the mantel hook brackets. See Diagram 3. Then lower the suite down to rest on the wall mount bracket. Great care must be taken to route the fire power cable correctly as indicated in Diagram 4, confirming the cable is not crushed or damaged on installation. The suite should now be correctly positioned.

  2. Secure the fire
    To secure the suite to the wall mount bracket fix with the provided screws through the base of the wall mount bracket up into the suite (see Diagram 5). This will lock the suite in position.
    This completes the wall mounted installation option. For dressing the logs and fire operation, please refer to the separate fire instructions.

  3. Assemble the plinth
    For the floor standing suite installation. The base plinth will need to be unpacked and assembled. The base plinth comprises of four main parts which should be built up and fixed together with the provided 7-off cam fixings and 4-off dowels (see Diagram 6). Once assembled the base plinth can be positioned centrally under the suite to complete the floor standing suite installation. Should you require a permanent fix use the mantle hooks and angle brackets provided.

Maintenance

WARNING: Before any maintenance or whilst cleaning the exterior of the fireplace, the unit should be disconnected from the power supply until it has cooled down.

Cleaning the Fire

Cleaning or polishing products are not recommended. Fingerprints or other marks on the front glass panel can be removed by a piece of soft, damp, lint- free cloth with a good quality household glass cleaner. The front glass panel should always be completely dried with a clean, lint-free cloth or paper towel.
CAUTION: Abrasive cleaners should not be used on the glass panel. Liquids should not be sprayed directly onto any surface of the unit.

Troubleshooting

Should you have any queries regarding this product please contact Customer Services on 0191 4300901 or email us at [email protected]

Recycling

All cardboard packing is recyclable

IMPORTANT NOTE:
Wall fixings (i.e. screws/wall plugs etc.) are not supplied as these are crucially dependent upon the type of wall and surface the surround is going to be fixed too. The installer is therefore responsible for ensuring that suitable fittings are used according to the particular model to be installed as well as individual fitting situations and environments. All mechanical fixings, for holding the suite in position, must be secured to a solid wall or structure.