timberk T-PAC12-P11E Portable Type Electric Air Conditioner Instruction Manual

June 10, 2024
TIMBERK

timberk T-PAC12-P11E Portable Type Electric Air Conditioner

Product Information: Portable Type Electric Air Conditioner

This is a portable type electric air conditioner with the model number T-PAC12-P11E. It has a cooling capacity of 12000 BTU and uses R290 refrigerant. The product is Class I rated and has a voltage rating of 220-240~/50Hz. The product dimensions are 420360720mm.

Product Usage Instructions

  1. Before using the air conditioner, make sure to read the instruction manual carefully.
  2. Place the air conditioner in a location where it has proper ventilation and is not blocked by any obstacles.
  3. Connect the air conditioner to a power source and switch it on.
  4. Choose the desired mode of operation and adjust the temperature settings accordingly.
  5. Use the remote control to adjust settings such as fan speed, swing, and timer.
  6. When the product is not in use, turn it off and unplug it from the power source.
  7. Clean the air filter regularly to ensure proper functioning of the product.
  8. If you face any issues or have any questions, refer to the troubleshooting section in the instruction manual or contact customer support.
  9. Do not attempt to disassemble or repair the product on your own. Seek professional help if required.
  10. Dispose of the product responsibly and in accordance with local regulations.

IMPORTANT INFORMATION

The appliance is designed for air cooling, dehumidifying, ventilating in domestic premises. The manufacturer reserves the right to make minor changes to the design of the product without additional notice that do not fundamentally affect its safety, performance and functionality. There may be some misprints in text and digital notations in the present manual. In case after reading of this manual you have any questions concerning work and operation of the appliance, please, refer to a shop assistant or to a specialized service center for further explanations. The device has a label with all the needed technical data and other useful information about the appliance. Use the appliance only for its intended purposes indicated in this manual.

SAFEGUARDS

When using an electric air conditioner, a number of safety precautions must be observed. Improper operation by ignoring safety precautions can result in damage to the health of the user and other people, as well as damage to their property.

  • Read these instructions carefully before using the appliance to avoid damage during use.
  • Before starting up for the first time, check that the specifications on the product comply with the power supply specifications.
  • Do not use outdoors or in high humidity.
  • To avoid damage to the air conditioner and cancellation of your warranty, put the device in an upright position at least 2 hours before use.
  •  If after reading the instructions you still have questions about the operation and operation of the device, contact the seller or a specialized service center for clarification.
  • On the product there is a label on which all the necessary technical data and other useful information about the device are indicated.
  • Use the appliance only for the purpose specified in this manual.
  • Before installing a mobile air conditioner without connecting it to the mains, check and make sure that the power outlet for the air conditioner has a ground contact and is properly grounded.
  • Make sure that the power cord does not touch sharp edges or hot surfaces.
  • The manufacturer reserves the right to make minor changes to the design of the product without additional notice that do not fundamentally affect its safety, performance and functionality.
  • Always unplug the device before assembling, disassembling and cleaning, or if you are not using it.
  • If the product was at a temperature below 0ºC for some time, it must be kept at room temperature for at least 2 hours before turning it on.
  • If there is no ground circuit in your electrical system, the operation of a mobile air conditioner is life threatening.
  •  Do not use adapters or extension cords to connect your mobile air conditioner.
  • Improper installation and use of this air conditioner can result in serious injury or damage to your property.
  • Any service work must be carried out by a specialized organization and qualified specialists. Do not attempt to repair the device or replace any parts by yourself. If you find a problem, contact your nearest Service Center.
  • Do not block the air inlet and outlet.
  • Make sure that the air inlet and outlet are free from any foreign objects.
  • Do not insert objects into the air outlet grilles of the air conditioner. This is very dangerous because the fan rotates at high speed.
  • Install the device on a horizontal surface to prevent condensate (water) leakage.
  • Do not install the floor air conditioner in the following places:
    • In places exposed to direct sunlight;
    • Near sources of open flame;
    • Near other operating heating appliances;
    • In places where splashing water or steam is possible on the device;
    • In rooms with high humidity;
    • Close to pools, bathrooms and showers.
  • Do not use the device in explosive or corrosive environments. Do not store gasoline or other volatile flammable liquids near the air conditioner – this is very dangerous!
  • Use the device to cool the air at an ambient temperature of 17-35°C.
  • Clean the filters periodically to ensure effective operation of the device.
  • To ensure reliable compressor operation, do not tilt the air conditioner.
  • If the device is turned off, it must be switched back on no earlier than after 3.5 minutes in order to avoid compressor malfunction.
  • For the compressor to work, the electrical outlet must be rated for a rated current of at least 10A. To avoid overheating and the risk of fire, as well as damage to the internal electrical network, do not plug the device into extension cords.
  • Use only for domestic purposes in accordance with this instruction manual. The device is not intended for industrial use.
  • If the power cord is damaged, it must be replaced by the manufacturer, customer service, or similar qualified personnel to avoid danger.
  • Before disposing of the device, remove the batteries from the remote control, they must be disposed safely.
  • The device is not intended for use by persons (including children) with reduced physical, sensory or mental abilities or in the absence of their life experience or knowledge, unless they are supervised or instructed on the use of the device by the person responsible for their safety. Children must be supervised to prevent playing with the appliance.
  • Do not use accessories that are not supplied.
  • When disconnecting the appliance from the mains, do not pull on the power cord, grasp the plug. Do not twist and do not wind it on anything.
  • The appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and maintenance shall not be made by children without supervision.
  • The unit is designed only for use with R-290(propane) gas as the designated refrigerant.
  • Install, operate and store the device in a room with an area of more than 12 m2.
  • Store the device in a well-ventilated place. The non-ventilated area, where the device is installed, shall be arranged in such a way that, in case of cooling agent leakage, it does not stagnate, in order to prevent the risk of fire or explosion.
  • Do not use the device in laundry and washing rooms (or rooms used for this purpose).
  • The appliance must be installed in accordance with national electrical installation regulations.
  • Pictograms interpretation:
    • Warning! Fire hazard/flammable materials.
    • Please read the operation manual before installing and using.

 APPOINTMENT OF THE DEVICE

Portable air conditioner is intended for cooling, dehumidifying, ventilating in domestic premises.

DEVICE DESCRIPTION

Fig.1
The appearance of the air conditioner may differ from the images in the manual.

  1. Top cover
  2. Control panel
  3. Handle
  4. Front side body
  5. Rollers
  6. Air filter
  7. The opening for the drain hose (for аutomatic condensate removal)
  8. Handle
  9. The opening for the warm air
  10. Air inlet grille
  11.  Drainage hole
  12. Air exhaust hose
  13. Blinds
  14.  Power cord
  15. Plug
  16.  Cord storage compartment
  17. Display and indicator FULL

DELIVERY SET

  1. Portable air conditioner – 1 pc.
  2. Remote control – 1 pc.
  3. Air outlet hose – 1 pc.
  4. Window sealing plate assembly– 1 pc
  5. Packing of the device – 1pc.
  6. Instruction manual – 1 pc.
  7. Warranty card – 1 pc.

SPECIFICATIONS

Technical specifications
Technical specifications of the device are indicated in table.

Parameter Units T-PAC12-P11E
Capacity (cooling) BTU (kW) 12000(3530)
Rated power consumption (cooling) W 1357
Power supply V/Hz 220-240~/50
Rated power current (cooling) А 5.9
Air consumption m³/h 400
Water tank volume l 0.8
Capacity of draining l/d 55
Noise level dB(A) 65
Refrigerant R290
Energy efficiency (cooling) А
Coefficient of energy efficiency 0.99
Electrical protection class Class I
Filling of refrigerant g 230
Operating temperature range: cooling °С 15-35
Service area of the device m2 18-26
Annual energy consumption (cooling mode) kW*h/year 1134
Operating mode (cooling/cooling + heating) cooling
--- --- ---
Cooling type (air/water) air
Compressor Ruizhi
Max allowable pressure (suction/ discharge) MPa 3(0.6/1.8)
Net weight kg 27
Gross weight kg 30.7
Net dimensions mm 420360720
Packing dimensions mm 477397875

DEVICE INSTALLATION

Warning
before using the mobile air conditioning, keep it upright for at least two hours. The air conditioning can be easily moved in the room. In the moving process, ensure that the air conditioning is in the upright position and the air conditioning should be placed on a flat surface. Do not install and use the air conditioning in the bathroom or other humid environments.

Install the heat pipe assembly (as shown in Fig.2)

  1. Take out the outer connector assembly and the exhaust pipe assembly, and remove the plastic bags;
  2. Insert the heat pipe assembly (the end of the exhaust joint) into the back panel ventilate (push to the left) and complete the assembly (as shown in Fig. 2).

Installation of window sealing plate components

  1. Half open the window,and mount the window sealing plate assembly to the window (as shown in Fig.3 and Fig.4).Components can be placed in horizontal and vertical direction.
  2. Pull various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fix various components of the assembly.

Install the window sealing plate assembly

  1. The flat end of the exhaust pipe joints must be snapped into place.
  2. The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep the ventilation of the exhaust pipe not blocked.

Install the body

  1. Move the machine with installed heat pipe and fittings before the window, and the distance between the body and walls or other objects shall be least 50 cm (as shown in Fig.5).

Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of the window sealing plate assembly (as shown in Fig.6 and Fig.7).

timberk-T-PAC12-P11E-Portable-Type-Electric-Air-
Conditioner-08

Important Notice
The length of the exhaust hose shall be 280~1,500mm, and this length is based on the specifications of the air conditioning. Do not use extension tubes or replace it with other different hoses, or this may cause a malfunction. Exhaust host must be not blocked; otherwise it may cause overheating.

DEVICE CONTROL

Control panel

  1. When the machine is powered on for the first time, the buzzer will play power-on music, and then the machine will get into standby status.
  2. Power
    • press the key to turn on and turn off the machine. In the case of power on, press the key to turn off the machine; in the case of power off,
    • press the key to turn on the machine.
  3. Mode: In the case of power on, press the key to switch between cooling → fan → dehumidifying mode.
  4. Up /Down
    • press the two keys to change the setting temperature or setting time, operate as follows:
    • While setting temperature, press up key or down key to select the required temperature (not available in fan or dehumidifying mode).
    • While setting time, press up key or down key to select the required time.
  5. Fan:
    • In cooling and fan mode, press the key to select high, low wind speed operation. But limited by anti-cold conditions, under certain conditions, it may not run according to the set wind speed.
    • In dehumidifying mode, pressing the key is invalid, and the fan will forcibly choose low wind speed operation.
  6. Timer :
    • In the case of power on, press the key to close timing; in the case of power off, press the key to open timing.
    • Press the key, when the timing symbol flashes, press up and down key to select the required timing value.
    • Timing values can be set in 1-24 hours and the timing value is adjusted up or down by one hour.
  7. Sleep: In the cooling Mode, Press the UP and Fan Key to turn on the sleep mode, then the unit will work on Energy-Saving and quiet type.

Remote control

press the key to turn on o turn off the machine.
press the key to set timing.
press the key to reduce/ increase temperature and timing set value.
press the key to switch between cooling, fan, heating, dehumidifying mode.
press the key to select high, low wind speed.
Press the key to turn on the sleep mode.
Press the louver will swing up and down (optional).
press to change 45 °C and °F on display. The remote is powered by two AAA batteries (not included).

Protection function

Frost Protection Function:
In cooling, dehumidifying or economic power saving mode, if the temperature of the exhaust pipe is too low, the machine will automatically enter protection status; if the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to normal operation.

2 Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will automatically sound an alarm, and the “FULL” indicator light will flash. At this point, you need to move the drainage pipe connecting the machine or the water outlet to sewer or other drainage area to empty the water (details see Drainage Instructions at the end of this chapter). After the water is emptied, the machine will automatically return to the original state.

3 Automatic Defrosting (cooling models have this function)
The machine has automatic defrosting function. Defrosting can be achieved through four – way valve reversing.

4 Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection function after the compressor is turned off.

MAINTENANCE

ATTENTION
Disconnect the unit from the mains before cleaning.
Condensate removal instructions

  1. When condensate is filling the tank, switch off the air conditioner and turn off the power.
    Note: Move the device carefully to avoid spilling of water in the bottom of the case

  2. Place the water container behind the outlet at the rear part of the device

  3. Unscrew the drain cap and pull out the plug, the water will automatically flow into the water tank.

Note:

  1.  Hold the drain plug cover, and the water plug properly.
  2. During drainage, the housing may be tilted slightly backwards.

Note
If the water container can’t contain all the condensate from the air conditioner, cover the drain with a plug as soon as possible to prevent water from spilling onto the  floor.

When the water is drained, stick water plug and tighten the drain cap.
Note: Continue to operate the device only after installing the water plug and drain cap to prevent condensation from spilling onto the floor.

Automatic condensate removal (optional, only works in DRY mode)

  1. Unscrew the drain cap and remove the water plug.
  2. Install the drain hose* into the drain hole
  3. Put the drain hose* in the water container

Not supplied

Fig.9

  1. When cleaning the air conditioner, do not use gasoline, solvents and other chemically active substances.
  2.  To avoid electric shock and damage to electrical components, do not pour water on the air conditioner from a tap or a hose.
  3. Do not use the air conditioner if the power cord is damaged. On the subject of replacing a damaged power cord, contact an authorized service center.

Air filter
Clogging with dust particles impairs the air conditioner operation efficiency, therefore clean the filter no less than once in two weeks.

Filter removal/installation
On the back of the housing, slide the plastic lock, unscrew the four screws and pull out the filter frame (as shown in the figure below)

Filter cleaning
To clean the filter, put it in warm water with a mild detergent (with a temperature of about 40° C), rinse it and remove any dirt. Before installing the filter in the air conditioner, it is necessary to dry it, avoiding direct sunlight.

Air intakes (heat exchangers)
Use a vacuum cleaner for cleaning

Case
Wipe the surface by a damp cloth and dry it by a soft dry cloth.

Unit Storage

  1. Unscrew the drainage cover, unplug the water plug, and discharge the water in the water pan into other water containers or directly tilt the body to discharge the water into other containers.

  2. Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes
    dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.

  3. Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install the water plug and the drainage cover.

  4. Remove the exhaust pipe and keep it properly.

  5. Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it out of the reach of children, and take dust control measures.

  6. Remove batteries of the remote control and keep them properly.
    Note : ensure that the body is placed in a dry place and keep all machine components properly.

SAFETY PRECAUTIONS ON SERVICING

  • * Read the technical manual

ATTENTION
Any person involved in service work on the device or intervention in the refrigerant circuit must go through special training, confirmed by a certificate.
Please follow these warnings when to undertake the following when servicing a dehumidifier with R290.

  1. Checks to the area
    Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

  2. Work procedure
    Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.

  3. General work area
    All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

  4. Checking for presence of refrigerant
    The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.

  5. Presence of fire extinguisher
    If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder orCO2 fire extinguisher adjacent to the charging area.

  6. No ignition sources
    No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

  7. Ventilated area
    Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

  8. Checks to the refrigeration equipment
    Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:

    • The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
    • The ventilation machinery and outlets are operating adequately and are not obstructed;
    • If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
    • Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
    • refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
  9. Checks to electrical devices
    Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
    Initial safety checks shall include:

    • Those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
    • That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
    • That there is continuity of earth bonding

Maintenance of sealed components

It is important to ensure that all power sources are disconnected from the operating equipment during the maintenance of sealed components, before removing the sealing covers, etc.

In case of necessity to provide power to the equipment during maintenance, it is important to provide a permanent leak detection system at the most critical point in order to warn of a potentially dangerous situation. Pay particular attention to ensure the impossibility to change/damage/deform the housing when working with electrical components in such a way as to affect the protection level, namely: damage to cables, excessive number of connections, non- compliance of terminals with the original specification, damage to seals, improper installation of oil seals, etc. Make sure that the device is installed in a secure manner. Make sure that the seals or sealing materials are not worn to such an extent that they no longer prevent the passage of flammable substances. Spare parts shall comply with the manufacturer’s specifications.

NOTE
The use of silicone sealant can reduce the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated before working on them.

Maintenance of intrinsically safe components

Before applying permanent inductive or capacitive loads to the circuit, ensure that they do not exceed the permissible voltage and current allowed for the equipment. Structurally intrinsically safe components shall be the only type of equipment that can be operated under voltage in case of a flammable atmosphere. The test equipment shall be of the appropriate class. The components shall only be replaced with the parts specified by the manufacturer. Other parts may ignite the cooling agent in the atmosphere due to its leakage.

Wiring

Make sure the cables are not exposed to wear, corrosion, overpressure, vibration, damage due to contact with sharp edges, or any other adverse environmental effects. Take into account also the effects of wear from physical obsolescence or constant vibration from such sources as compressors or air fans.

Flammable cooling agents leak detection

Do not use appliances that can be a potential source of ignition when searching for or detecting cooling agent leaks under any circumstances. The use of halogen leak detectors (or any other means of open flame detection) is prohibited.

Leak detection methods

The following leak detection methods shall be considered as acceptable for systems containing highly flammable cooling agents. In order to detect flammable cooling agents, use electronic leak detectors, however, the sensitivity may be insufficient or recalibration may be required (the detection equipment shall be calibrated in a cooling agent-free area.) Make sure that the detector cannot serve as a potential source of ignition and is suitable for the used cooling agent. Leak detection fluids are suitable for application with most cooling agents, however, the use of detergents containing chlorine shall be avoided, as the chlorine may react with cooling agent and corrode the copper piping. In case of leakage, remove / extinguish all open flame sources. All the cooling agents shall be removed from the system in case of necessity of soldering, due to the existence of cooling agent leakage. The oxygen-free nitrogen (OFN) shall then be purged through the system both before and during the soldering process.

Removal and vacuuming

The usual procedures shall be followed when interfering with the cooling agent circuit to carry out repairs or for any other purpose. It is necessary to take into account the flammability of the cooling agent when performing these procedures.

Carry out the following procedures

  • Remove the cooling agent;
  • Purge the circuit with an inert gas;
  • Pump out the gas;
  • Purge with an inert gas again;
  • Open the circuit, using soldering or trimming

It is necessary to extract the cooling agent into special cylinders for extracting the cooling agents,. The system shall be “flushed” with oxygen-free nitrogen (OFN) to make the device safe. This process may need to be repeated several times. Do not use compressed air or oxygen in this procedure.
Flush the system by breaking the vacuum in it with oxygen-free nitrogen (OFN) and continuing to fill it until reaching the operating pressure; then release it into the atmosphere, and then vacuum it again. This process shall be repeated until the complete absence of the cooling agent in the system. In case of use of the last charge of oxygen-free nitrogen (OFN), the system shall be reset to atmospheric pressure to ensure its operability.
This operation is totally necessary before soldering on the pipelines. Make sure that the outlet for the vacuum pump is not located near sources of ignition and that there is ventilation.

Cooling agent recharging procedure

The following requirements shall be met in addition to the regular charging procedures.

  • * Ensure the absence of cross-contamination of different cooling agents during the use of recharging equipment. Hoses or pipes shall be kept as short as possible in order to minimize the amount of cooling agent contained in them.
    • The cylinders for cooling agent recharging shall be in an upright position.
    • Ensure the grounding of the cooling agent system before recharging the system.
    • Mark the system when charging is complete.
    • Be careful, do not overfill the cooling system.
    • Test the system under pressure with oxygen-free nitrogen (OFN) before recharging it. The system shall be checked for leaks after charging is complete, but before commissioning. Subsequent leak testing shall be carried out before leaving the device installation site.

Decommissioning

The technician shall have enough knowledge of the equipment and all its details before carrying out this procedure. Requires extensive experience to extract the cooling agent safely. Before the procedure, take an oil and cooling agent sample in case of necessity of analysis before reuse of the regenerated cooling agent. It is important to use electricity only before the start of the procedure.

Procedure

  • De-energize the device
  • Before the procedure, make sure that all the necessary equipment is available for cooling agent cylinders; all personal protective equipment is available and used correctly; the process is controlled continuously by a competent person; the equipment and cylinders meet the required standards.
  •  Pump out the cooling agent system if possible.
  • If vacuuming is not possible, create a collector so that the cooling agent can be removed from various parts of the system.
  • Ensure that the cylinder is positioned on the scale before the procedure is performed.
  • Run the cooling agent pumping equipment and use it in accordance with the manufacturer’s instructions.
  • Do not overfill the cylinders (the liquid volume should not exceed 80%).
  • Do not exceed the maximum operating pressure of the cylinder, even temporarily.
  • After proper filling of the cylinders and completion of the process, make sure that the cylinders and equipment are removed from the procedure site and that all shut-off valves on the equipment are closed.
  •  The extracted cooling agent shall not be refilled into another cooling system unless it has been cleaned and checked.

Marking

The marking shall indicate that the equipment has been decommissioned and that cooling agent has been emptied. The label shall contain date and signature. Ensure that the equipment contains labels that denote that it contains a highly flammable cooling agent.

Cooling agent extraction

The staff shall have extensive experience in extraction of the cooling agent safely during equipment maintenance or decommissioning. When injecting the cooling agent into the cylinders, ensure the use of the appropriate cylinders. Ensure that the required number of cylinders is available to store the total system charge. Make sure that all the used cylinders are designed for the extracted cooling agent and have the marking appropriate for this type of cooling agent (i.e. special cylinders for the cooling agent extraction). The cylinders shall be equipped with a pressure relief valve and corresponding shut-off valves in proper working condition. Empty cylinders shall be vacuumed and, if possible, cooled prior to the start of the cooling agent pumping process. The pumping equipment shall be in proper working condition; it shall have a set of necessary instructions; and it shall be suitable for the extraction of flammable cooling agents. In addition, a set of calibrated scales shall be available and shall be in proper working condition. The hoses shall be complete with sealed disconnecting couplings and shall be in proper condition. Before using the device to pump out the cooling agent, make sure that it is in a satisfactory working condition, and that all relevant electrical components are sealed to prevent fire in case of cooling agent release. In case of any doubts, please contact the manufacturer. The collected cooling agent shall be returned to the supplier of the cooling agent in a proper container, with an appropriate waste material transfer invoice. Do not mix cooling agents in drain installations and especially in cylinders.
In case of necessity to remove the compressors or compressor oils, make sure that they have been pumped out to an acceptable level to ensure that no flammable cooling agent remains in the oiling. The pumping process shall be carried out before returning the compressor to the supplier. In order to speed up this process, use only electric heating of the compressor housing. Handle the oil safely after its extraction from the system.

WIRING DIAGRAMS

TROUBLESHOOTING

In case of emergency, please, use the troubleshooting methods shown in table. If it is impossible to solve problems with these methods, contact the authorized service center. Failures and their possible reasons:

Problems Reasons Solutions

The air conditioning does not work.

| There is no electricity.| Turn it on after connecting it to a socket with electricity.
The overflow indicator displays

“FL”.

| Discharge the water inside.
The ambient temperature is too low or too high| Recommend to use the machine in at the temperature of 7-35 ℃ (44-95

℉).

In cooling mode, the room temperature is lower than the set temperature; in heating mode, the room temperature is higher than the set

temperature.

|

Change the set temperature.

In dehumidification mode, the ambient temperature is low.| The machine is placed in a room with an ambient temperature of greater than 17 ℃ (62 ℉).
| There is direct sunlight.| Pull the Curtain.
The cooling effect is not good| Doors or windows are open; there are a lot of people; or in cooling mode, there are other

sources of heat.

|

Close doors and windows, and add new air conditioning.

---|---|---
The filter screen is dirty.| Clean or replace the filter screen.
The air inlet or outlet is blocked.| Clear obstructions.
Big Noise| The air conditioning is not

placed on a flat surface.

| Put the air conditioning on a flat and

hard place (to reduce noise).

compressor does not

work.

|

Overheat protection starts.

| Wait for 3 minutes until the temperature is lowered, and then

restart the machine.

The remote control does not work.

| The distance between the

machine and the remote control is too far.

| Let the remote control get close to the air conditioning, and make sure that the remote control directly faces to the direction of the remote control receiver.
The remote control is not aligned with the direction of the remote control receiver.
Batteries are dead.| Replace batteries.
Displays ‘E1’| The room temperature indicator is abnormal.| Check the room temperature indicator. Disconnection of contact assemblies is possible.
Displays ‘E2’|

The pipe room temperature is abnormal.

| Check the pipe temperature sensor. Possible failure, replacement is required.

UTILIZATION RULES

After the lifetime of the device expires, it should be recycled in compliance with the laws, rules and methods in region of recycling. Detailed information about the recycling of the device, you can receive from a representative of the local authorities, after providing full information about the device. The manufacturer and authorized organization of the manufacturer do not carry responsibility for the fulfillment by the Buyer of the requirements of legislation on utilization and methods of utilization of the device selected by the Buyer. The lifetime of the device is indicated in the warranty card. Warranty period for the device and warranty terms are specified in the warranty card. The warranty card is an integral part of the documentation supplied with this unit. If there is no warranty card in the delivery set, ask for it from the Seller. The warranty card provided by the Seller must conform to the manufacturer’s form. The manufacturer and the authorized organization of the manufacturer remove responsibility for any possible harm which can be caused to people, animals or property directly or indirectly, if this harm occurred as a result of noncompliance with the rules and operating conditions, installation of the device, intentional or reckless actions of the user- and / or third parties, as well as in situations caused by natural and / or anthropogenic accidents.

TRANSPORTATION AND STORAGE

  1. During transportation, any possible impacts and movements of the package inside the vehicle should be excluded.
  2. Transporting and storage should be provided in strict accordance to the manipulation marks.
  3. Outdoor unit should be transported vertical.

**Temperature Requirements*| Transportation and storage| From -30°C up to +50°C*
---|---|---
Humidity Requirements
| From 15% up to 85% (without a condensate)

  • We are exploring new technologies and we constantly improving the quality of our products. That’s why specifications, design and accessories are subject to change without any specific notice.
  • This product must have storage in dry, well-ventilated space of warehouse at the temperature not lower than +5°C.