SIEMENS Sentron JD Generator Quick Connect Switchboards Instructions

June 10, 2024
SIEMENS

SIEMENS Sentron JD Generator Quick Connect Switchboards

SIEMENS-Sentron-JD-Generator-Quick-Connect-Switchboards-
PRO

Product Information

Generator Quick Connect Switchboards
Siemens Energy Management Low Voltage and Products presents generator quick connect switchboards. These switchboards offer cam-type receptacles in addition to standard mechanical lugs, which allow for quick connection of a standby generator to a facility’s normal main service entrance switchboard. The quick connects can be supplied with either Sentron or VL molded case circuit breakers and also with WL insulated case circuit breakers as the generator disconnect. These switchboards are not selections in COMPAS, so the order entry guide is designed to help with submitting orders for this new product offering.
Siemens Energy Management Low Voltage and Products is pleased to announce generator quick connect switchboards. These switchboards are not selections in COMPAS so this order entry guide is designed to help with submitting orders for this new product offering.

Product Description

Generator quick connect switchboards supply cam-type receptacles in addition to standard mechanical lugs for the quick connection of a standby generator to a facility’s normal main service entrance switchboard.

Features and Functionality

  • 600 volts AC maximum

  • 4000 ampere maximum

  • All standard front connected switchboard features

  • Crouse-Hinds 4/0, 400A plug-in connectors are supplied as a
    standard, other connectors can be supplied if specified by the customer

  • NEMA 1 and NEMA 3R enclosures, NEMA 3R enclosures are supplied with a front trap door to maintain the switchboard rating with cables connected

  • A removable screw cover is supplied over the quick connects when they are not in use

  • Each quick connect plug-in is labeled with it’s intended connection (A, B, C or neutral phase)• Quick connects can be supplied in a standard lineup for new construction or remotely to a normal switchboard lineup for retrofit applications

  • Cam-type receptacles and standard mechanical lugs for quick connection of a standby generator.

  • Quick connects can be supplied with either Sentron or VL molded case circuit breakers and also with WL insulated case circuit breakers as the generator disconnect.

  • The generator disconnect must be provided with mechanical interlocking with the normal main disconnect.

  • Quick connects and the main disconnect can be supplied in a single section up to 2000 amperes.

  • If above 2000 amperes, a pull section is required and must be selected in COMPAS.

Standards and Certifications

  • UL891
  • NEC702
  • Florida Building Code section 420.4.2.9.7
  • Other equipment is UL listed as applicable

**Order Entry Information

**

The quick connects are priced at $1690 per quick connect, assuming each quick connect is 4/0 and carries 400 amperes. The prices in table 2 must be added as a factory option. See table 1 for a summary of all of the configuration information and table 2 for all of the pricing information.

InformationQuick connects can be supplied with either Sentron or VL molded case circuit breakers and also, WL insulated case circuit breakers as the generator disconnect. This generator disconnect must be provided with mechanical interlocking with the normal main disconnect.Quick connects and the main disconnect can be supplied in a single section up to 2000 amperes. Choose “main service” as the section type in COMPAS to ensure only one device is configured per section (see figure 1). If above 2000 amperes, a pull section is required and must be selected in COMPAS (see figure 2).See table 1 for a summary of all of the configuration information and table 2 for all of the pricing information. The prices in table 2 must be added as a factory option as shown in figures 3 and 4. The quick connects are priced at $1690 per quick connect assuming each quick connect is 4/0 and carries 400 amperes. The list price adders in table 2 are for all of the quick connects that would be required in the switchboard for each amperage and system phasing.

Configuration Information

Configuration Information Dimension (inches)
Ampere rating Pull selection required
Section depths Pull section width
Total width Device continuous current ratings
400 No
600 No
800 No
1200 No
1600 No
2000 No
2500 Yes
3000 Yes
4000 Yes

If the amperage is above 2000 amperes, a pull section is required and must be selected in COMPAS. Choose main service as the section type in COMPAS to ensure only one device is configured per section. See figure 1 for more information.

List Price Adders

Ampere rating| Quick connects per phase| Total list price adder (3-Phase, 4-Wire)| Total list price adder (3-Phase, 3-Wire)
---|---|---|---
400| 1| $8,788.00| $7,030.40
600| 2| $15,818.40| $12,303.20
800| 2| $15,818.40| $12,303.20
1200| 3| $22,848.80| $17,576.00
1600| 4| $29,879.20| $22,848.80
2000| 5| $38,667.20| $29,879.20
2500| 7| $52,728.00| $40,424.80
3000| 8| $59,758.40| $45,697.60
4000| 10| $75,576.80| $58,000.80

Ampere Rating and Quick Connects per Phase:

Ampere rating Quick connects per phase
400 1
600 2
800 2
1200 3
1600 4
2000 5
2500 7
3000 8
4000 10

Pricing Information:
Total list price adders are shown in table 2 for all of the quick connects that would be required in the switchboard for each amperage and system phasing. Total list price adder (3-Phase, 4-Wire) and Total list price adder (3-Phase, 3-Wire) are given in the table.

SIEMENS-Sentron-JD-Generator-Quick-Connect-
Switchboards-1 SIEMENS-Sentron-JD-
Generator-Quick-Connect-Switchboards-2 SIEMENS-Sentron-JD-Generator-Quick-Connect-
Switchboards-3

Product Usage Instructions

To use the generator quick connect switchboards, follow the steps below:

  1. Choose the amperage rating of the switchboard.
  2. If the amperage is above 2000 amperes, a pull section is required and must be selected in COMPAS.
  3. Choose the main device from the configuration information table.
  4. Determine the number of quick connects per phase based on the amperage rating and information provided in the Ampere Rating and Quick Connects per Phase table.
  5. If quick connects are needed, add them as a factory option as shown in figures 3 and 4.
  6. Ensure that the generator disconnect is provided with mechanical interlocking with the normal main disconnect.
  7. Choose main service as the section type in COMPAS to ensure only one device is configured per section.

If you have any questions regarding the guide or product, contact George Roscoe, Product Manager, Power Panels and Switchboards, at 770-326-2046 or george.roscoe@siemens.com.

For questions regarding this guide, contact:
George Roscoe, Product Manager, Power Panels and Switchboards 770-326-2046, george.roscoe@siemens.com

Published by
Siemens Industry, Inc. 2019.
Siemens Industry, Inc.
5400 Triangle Parkway
Norcross, GA 30092

For more information, please contact
our Customer Support Center.
Phone: 1-800-241-4453
E-mail: info.us@siemens.com
usa.siemens.com/switchboards
Order No. PDFL-GQCSB-0119
Printed in U.S.A.
© 2019 Siemens Industry, Inc.

The technical data presented in this document is based on an actual case or on as-designed parameters, and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects. Actual results are dependent on variable conditions. Accordingly, Siemens does not make representations, warranties, or assurances as to the accuracy, currency or completeness of the content contained herein. If requested, we will provide specific technical data or specifications with respect to any customer’s particular applications. Our company is constantly involved in engineering and development. For that reason, we reserve the right to modify, at any time, the technology and product specifications contained herein.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals