SPB Series DIN Rail Mount SMPS

Thank you for choosing our Auto nics product.
Read and understand the instruction manual and manual thoroughly before using the product.
For your safety, read and follow the below safety considerations before using.
For your safety, read and follow the considerations written in the instruction manual, other manuals and Auto nics website.
Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice.
Follow Auto nics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • ****symbol indicates caution due to special circumstances in which hazards may occur.

Warning Failure to follow instructions may result in serious injury or death.

  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in personal injury, economic loss or fire.
  2. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in explosion or fire.
  3. Install on the DIN rail, and ground to the F.G. terminal separately. Failure to follow this instruction may result in fire or electric shock.
  4. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in fire or electric shock.
  5. Check ‘Wiring Diagram’ before wiring. Failure to follow this instruction may result in fire.
  6. Do not disassemble or modify the unit. Failure to follow this instruction may result in fire or electric shock.

Caution Failure to follow instructions may result in injury or product damage.

  1.  When connecting the F.G. terminal, use AWG 14 (2.1mm2) cable or over and tighten the terminal screw with a tightening torque of 0.7 to 0.9N·m. When connecting the F.G. terminal of SPB-015/030 model, tighten the terminal screw with a tightening torque of 0.3 to 0.5N·m. Failure to follow this instruction may result in fire or malfunction due to contact failure.
  2. Use the unit within the rated specifications. Failure to follow this instruction may result in fire, product damage or shortening the life cycle of the product.
  3. Use dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in fire or electric shock.
  4. Keep the product away from metal chip, dust, and wire residue which flow into the unit. Failure to follow this instruction may result in fire or product damage.
  5. Do not touch the product during operation or for a certain period of time after stopping. Failure to follow this instruction may result in burns.
  6. Upon occurrence of an error, disconnect the power source. Failure to follow this instruction may result in fire or product damage.

Cautions during Use

  • Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.

  • Do not connect the output voltage neither in serial nor in parallel.

  • Since SPB-015/030/060 models have no harmonic suppression or power factor correction circuit, install the circuit separately if necessary.

  • Since SPB-015/030/060 models use the condenser input method, power factor is in the range of 0.4 to 0.6. When using distribution board or transformer, check the capacity of the input voltage.
    Input apparent power[VA] = Output active power[W]/Power factor×Efficiency

  • Even though a noise filter is installed inside the product, the product can be affected by noise depending on the installation location or wiring.

  • If the internal fuse is damaged, please contact our A/S center.

  • To ensure the reliability of the product, install the product on the panel or metal surface vertically to the ground.

  • Install the unit in the well ventilated place.

  • Do not use near the equipment which generates strong magnetic force or high frequency noise.

  • This unit may be used in the following environments.
    – Indoors (in the environment condition rated in ‘Specifications’)
    – Altitude max. 2,000m
    – Pollution degree 2
    – Installation category I

Ordering Information

This is only for reference.
For selecting the specific model, follow the Auto nics web site.

Autonics SPB Series DIN Rail Mount SMPS - Fig

  1. Output power
    Number: Output power (unit: W)

  2. Output voltage
    Number: Output voltage (unit: VDC~)

Specifications

Output range 15 to 31.2 W
Model SPB-015- 05
SPB-030- 05 SPB-030- 12
Output power 15 W

Input condition
Voltage 01)| 100 – 240 VAC~ (permissible voltage: 85 – 264 VAC~/ 120 – 370 VDC~)
Frequency| 50 / 60 Hz
Efficiency 02) (Typical)| 100 VAC~| 77%| 80%| 83%| 77%| 82%| 84%
240 VAC~| 76%| 79%| 82%| 78%| 83%| 85%
Power factor 02)| –| –
Max. current consumption 02)| 0.4 A| 0.8 A
Current consumption 02 (Typical)| 100 VAC~| 0.35 A| 0.35 A| 0.34 A| 0.56 A| 0.63 A| 0.63 A
240 VAC~| 0.19 A| 0.19 A| 0.19 A| 0.30 A| 0.35 A| 0.35 A
Output characteristics
Voltage| 5 VDC| 12 VDC| 24 VDC| 5 VDC| 12 VDC| 24 VDC
Current| 3 A| 1.3 A| 0.65 A| 5 A| 2.5 A| 1.3 A
Voltage adjustment range| ≤ ±10%| ≤ ±10%
Input variation 03)| ≤ ±0.5%| ≤ ±0.5%
Load variation| ≤ ±1%| ≤ ±1%
Ripple noise 02), 04)| ≤ ±1.5%| ≤ ±1%| ≤ ±1%| ≤ ±1.5%| ≤ ±1%| ≤ ±1%
Start-up time 02) (Typical)| 100 VAC~| 500 ms| 550 ms| 650 ms| 600 ms| 550 ms| 550 ms
240 VAC~| 550 ms| 550 ms| 650 ms| 600 ms| 550 ms| 550 ms
Hold time 02) (Typical)| 100 VAC~| 24 ms| 25 ms| 25 ms| 20 ms| 15 ms| 15 ms
240 VAC~| 190 ms| 190 ms| 190 ms| 130 ms| 110 ms| 110 ms
Protection
Inrush current protection (Typical)| 100 VAC~| 7 A| 7 A| 7 A| 7 A| 7 A| 6 A
240 VAC~| 32 A| 30 A| 31 A| 29 A| 31 A| 29 A
Over-current protection 04) 05)| 105 to 160%| 105 to 160%
Over-voltage protection 05)| –| –
Output low-voltage indicate| 4.2V
±10%| 9.6V
±10%| 20.0V
±10%| 4.2V
±10%| 9.6V
±10%| 20.0V
±10%
Power factor correction circuit| –| –
Approval 06)| |
Unit weight (Package)| ≈ 129 g (≈ 202 g)| ≈ 176 g (≈ 249 g)
Output range| 60 to 120 W
---|---
Mode| SPB-060- 12| SPB-060- 24| SPB-060- 48| SPB-120- 12| SPB-120- 24| SPB-120- 48
Output power| 60 W| 60 W| 62.4 W| 96 W| 120 W| 120 W
Input condition
Voltage 01)| 100 – 240 VAC~ (permissible voltage: 85 – 264 VAC~ / 120 – 370 VDC~)
Frequency| 50 / 60 Hz
Efficiency 02) (Typical)| 100 VAC~| 81%| 84%| 85%| 82%| 85%| 85%
240 VAC~| 83%| 86%| 87%| 85%| 88%| 88%
Power factor 02)| –| ≥ 0.9
Max. current consumption 02)| 1.6 A| 1.9 A
Current consumption 02)

(Typical)

| 100 VAC~| 1.24 A| 1.21 A| 1.19 A| 1.19 A| 1.49 A| 1.43 A
240 VAC~| 0.66 A| 0.65 A| 0.64 A| 0.52 A| 0.61 A| 0.61 A
Output characteristics
Voltage| 12 VDC| 24 VDC| 48 VDC| 12 VDC| 24 VDC| 48 VDC
Current| 5 A| 2.5 A| 1.3 A| 8 A| 5 A| 2.5 A
Voltage adjustment range| ≤ ±5%| ≤ ±5%
Input variation 03)| ≤ ±0.5%| ≤ ±0.5%
Load variation| ≤ ±1%| ≤ ±1%
Ripple noise 02), 04)| ≤ ±1%| ≤ ±1%
Start-up time 02)

(Typical)

| 100 VAC~| 520 ms| 550 ms| 1200 ms| 1200 ms| 1200 ms| 1200 ms
240 VAC~| 530 ms| 550 ms| 400 ms| 400 ms| 400 ms| 400 ms
Hold time 02) (Typical)| 100 VAC~| 15 ms| 14 ms| 15 ms| 98 ms| 75 ms| 87 ms
240 VAC~| 100 ms| 110 ms| 108 ms| 97 ms| 43 ms| 86 ms
Protection
Inrush current protection (Typical)| 100 VAC~| 13 A| 14 A| 10 A| 9 A| 11 A| 10 A
240 VAC~| 19 A| 17 A| 37 A| 37 A| 36 A| 37 A
Over-current protection 04) 05)| 105 to 160%| 105 to 160%
Over-voltage protection 05)| –| 16.0 V
±10%| 30.0 V
±10%| 58.0 V
±10%
Output low-voltage indicate| 9.6 V
±10%| 20.0 V
±10%| 43.0 V
±10%| 9.6 V
±10%| 20.0 V
±10%| 43.0 V
±10%
Power factor correction circuit| –| Built-in
Approval 06)| |
Unit weight (Package)| ≈ 274 g (≈ 347 g)| ≈ 466 g (≈ 570 g)
Output range| 180 to 240 W
---|---
Model| SPB-180-24| SPB-180-48| SPB-240-12| SPB-240-24| SPB-240-48
Output power| 180 W| 182.4 W| 240 W
Input condition
Voltage 01)| 100 – 240 VAC~ (permissible voltage: 85 – 264 VAC~ / 120 – 370 VDC ~)
Frequency| 50 / 60 Hz
Efficiency 02) (Typical)| 100 VAC~| 89%| 89%| 87%| 89%| 89%
240 VAC~| 92%| 92%| 90%| 92%| 92%
Power factor 02)| ≥ 0.9| ≥ 0.9
Max. current consumption 02)| 3.0 A| 3.8 A
Current consumption 02)

(Typical)

| 100 VAC~| 2.03 A| 2.04 A| 2.76 A| 2.71 A| 2.73 A
240 VAC~| 0.83 A| 0.84 A| 1.14 A| 1.12 A| 1.13 A
Output characteristics
Voltage| 24 VDC| 48 VDC| 12 VDC| 24 VDC| 48 VDC
Current| 7.5 A| 3.8 A| 20 A| 10 A| 5 A
Voltage adjustment range| ≤ ±5%| ≤ ±5%
Input variation 03)| ≤ ±0.5%| ≤ ±0.5%
Load variation| ≤ ±1%| ≤ ±1%
Ripple noise 02), 04)| ≤ ±1%| ≤ ±1.5%| ≤ ±1%| ≤ ±1%
Start-up time 02)

(Typical)

| 100 VAC~| 87 ms| 75 ms| 75 ms| 87 ms| 75 ms
240 VAC~| 56 ms| 45 ms| 45 ms| 56 ms| 45 ms
Hold time 02) (Typical)| 100 VAC~| 36 ms| 25 ms| 33 ms| 36 ms| 25 ms
240 VAC~| 36 ms| 25 ms| 33 ms| 36 ms| 25 ms
Protection
Inrush current protection (Typical)| 100 VAC~| 8 A| 8 A| 8 A| 8 A| 8 A
240 VAC~| 25 A| 26 A| 22 A| 25 A| 26 A
Over-current protection 04) 05)| 105 to 160%| 105 to 160%
Over-voltage protection 05)| 30.0 V
±10%| 58.0 V
±10%| 16.0 V
±10%| 30.0 V
±10%| 58.0 V
±10%
Output low-voltage indicate| 20.0 V
±10%| 43.0 V
±10%| 10.0 V
±10%| 20.0 V
±10%| 43.0 V
±10%
Power factor correction circuit| Built-in| Built-in
Approval 06)| |
Unit weight (Package)| ≈ 505 g (≈ 609 g)| ≈ 736 g (≈ 866 g)

  1. Since there is no separate input over-voltage protection for the voltage over the rated input voltage range, supplying over-voltage may result in product damage.
  2. It is for 100% load condition.
  3. It is in the rated input voltage 100-240VAC~ (85-264VAC~) with 100% load.
  4. It is for the rated input voltage 100-240VAC~.
  5. Refer to the catalog to check the related feature data.
  6. It is for AC power input only.
Indicator Output indicator (green), output low-voltage indicator (red)
Insulation resistance ≥ 100 MΩ (500 VD megger, between all input

and output terminals)
Dielectric strength| 3,000 VAC~ 50/60 Hz for 1 min (between all input and output terminals) 1,500 VAC~ 50/60 Hz for 1 min (between all input terminals and F.G.)
Vibration| 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock| 300 m/s2 (≈ 30G) in each X, Y, Z direction for 3 times
EMS| Conforms to EN61000-6-2
EMI| Conforms to EN61000-6-4
Ambient temperature 01)| -10 to 50 ℃, storage: -25 to 65 ℃ (no freezing or condensation)
Ambient humidity| 25 to 85%RH, storage: 25 to 90%RH (no freezing or condensation)
Protection structure| IP20 (IEC standard)

  1. UL approved ambient temperature is 40℃, refer to ‘Output De-rating Curve by Ambient Temperature’.

Dimensions

  • Unit: mm, refer to the Auto nics website for the details of the product.
  • This is based on SPB-030 model.

Autonics SPB Series DIN Rail Mount SMPS - FIg1

| A| B| C| D| E| F| G| H
---|---|---|---|---|---|---|---|---
SPB-015| Output indicator: DC ON, Green| Output low voltage indicator: DC LOW, Red| ** Output voltage adjuster: V.ADJ 01)| 107| 100| 90| 22.5| 90
SPB-030| 107| 100| 90| 30| 90
SPB-060| 117| 110| 100| 36| 110
SPB-120| 132| 125| 115| 50| 110
SPB-180| 132| 125| 115| 50| 110
SPB-240**| 132| 125| 115| 80| 110

  1. Use within the voltage variable range. If the voltage exceeds the output voltage range, over-voltage protection function is activated and the output is cut off.

Connection

Mark Function
+V Output power (+)
-V Output power (-)
L, N Input power
F.G. Frame ground
Wire Terminal
--- ---
SPB-015 01) AWG 24 to 19 (Material: Cu)

SPB-030
SPB-060 01)| AWG 21 to 19 (Material: Cu)| 5-M3.5| 0.7 to 0.9 N·m
SPB-120| 7-M3.5
SPB-180
SPB-240| AWG 18 to 16 (Material: Cu)| 7-M3.5| 0.7 to 0.9 N·m

Installation

■ Mounting on DIN rail
Put the product on DIN rail and press it to the direction ①.

■ Removing from DIN rail
Put a screw driver into the rail hook, push it to the direction ①, and lift the product to the direction ②.

■ Installation interval

  • When installing multiple SMPSs, please keep space at least 20 mm between SMPSs for heat radiation.
  • In case of the top and bottom of the product, please keep space at least 75 mm.

Over heating Protection

The over-heating protection function cuts off the output voltage when the temperature in an element increases due to over-heating.
When the over-heating protection function is activated, the product does not work properly. Please resupply power after cooling the product sufficiently.
Output De-rating Curve by Ambient Temperature

18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com
+82-2-2048-1577
sales@autonics.com