Wallgate INS-PSHD30 Anti-Ligature Hand Wash Dryer Instructions

June 10, 2024
Wallgate

Wallgate INS-PSHD30 Anti-Ligature Hand Wash Dryer

Dimension

NOTES:

  1. THE AIR GRILLE IS SLOTTED WITH THE SLOTS BEING 2mm WIDTH. ONE WEB RUNS HORIZONTALLY TO REDUCE THE VERTICAL SLOT LENGTH
  2. THE WATER AND SOAP NOZZLES HAVE 2mm OUTLET HOLES
  3. THE WASTE GRILLE IS SLOTTED WITH THE SLOTS BEING 2mm WIDTH. A WEB RUNS HORIZONTALLY TO REDUCE THE VERTICAL SLOT LENGTH.
  4. THE HANDWASH FASCIA IS DESIGNED TO BE AS ANTI LIGATURE AS POSSIBLE WITH INTERNAL FACES ANGLED TO PREVENT ITEMS BEING JAMMED INTO THE BOWL.

Dimension
Dimension
Dimension

NOTES:

  1. THIS SHEET SHOWS THE CONTROL MODULE IN ITS STANDARD MOUNTING POSITION. THE CONTROL MODULE SITS BEHIND THE FASCIA FOR EASE OF CONNECTION
  2. THE UNIT REQUIRES A WALL APERTURE OF 375mm WIDTH BY 380mm HEIGHT.
  3. THE BASIN WASTE PIPE SHOULD BE CONNECTED TO A 1 1/2″ (40mm NOMINAL) DEEP SEAL WASTE TRAP (NOT SUPPLIED), A RUNNING TRAP IS NOT RECOMMENDED FOR THIS PRODUCT.
  4. A WATER SUPPLY OF MINIMUM 1.0 Bar IS REQUIRED FOR CONNECTION TO THE WATER INLET ON THE FRONT OF THE UNIT. THE SUPPLY IS TO BE ROUTED THROUGH THE PROVIDED ISOLATOR VALVE.
  5. THE CONTROL MODULE IS SUPPLIED WITH A 2 METER CABLE WITH EXPOSED ENDS FOR CONNECTION TO A 230v AC 50Hz 13Amp ELECTRICAL SUPPLY.
  6. THE WATER HEATER SUPPLIED WITH 0.7M FLYING LEAD TO BE INSTALLED INTO A SEPARATE 230v AC 50Hz 13Amp FUSED SPUR AS PER ZIP ES3 MANUAL.
  7. FULL INSTALLATION DETAILS CAN BE FOUND IN THE PSH_30 PRODUCT MANUAL SUPPLIED WITH THIS PRODUCT.
  8. THE FASCIA CAN BE INSTALLED MOUNTED IN WALLS BETWEEN 13mm AND 175mm THICK. LONGER STUD BARS CAN BE PURCHASED FOR INSTALLATION INTO THICKER WALLS.
  9. ENSURE 100mm CLEARANCE ABOVE THE AIR INTAKE TO ENSURE ADEQUATE AIRFLOW TO THE UNIT.

Dimension

NOTES:

  1. THIS SHEET SHOWS THE OVERALL DIMENSION FROM THE FRONT OF THE WALL TO THE REAR OF THE HEATER, DIMENSION X. ON A 13mm WALL X = 358mm. (13mm WALL + 113mm SPACER+ 232mm CONTROL MODULE). ON A 175mm WALL X = 427mm. (175mm WALL + 232mm CONTROL MODULE).

Dimension

Overview

NOTES:

  1. THIS SHEET SHOWS A REMOTE MOUNTING POSITION FOR THE CONTROL MODULE WITH THE AIR CONNECTED TO THE FASCIA THROUGH AN LONG FLEXIBLE AIR HOSE. THIS FACILITY ALLOWS THE CONTROL MODULE TO BE MOUNTED IN A VARIETY OF DIFFERENT POSITIONS TO SUIT SITE REQUIREMENTS. (PLEASE NOTE: IF THIS INSTALLATION METHOD IS REQUIRED IT MUST BE REQUESTED WHEN THE ORDER IS PLACED SO THAT THE APPROPRIATE CONNECTIONS CAN BE SUPPLIED.)
  2. THE FASCIA REQUIRES A WALL APERTURE OF 375mm WIDTH BY 380mm HEIGHT.
  3. THE SOAP CONTAINER HANGS ON A BRACKET THAT CAN BE WALL MOUNTED TO SUIT REQUIREMENTS ON SITE.
  4. THE BASIN WASTE PIPE SHOULD BE CONNECTED TO A 1 1/2 ” (40mm NOMINAL) DEEP SEAL WASTE TRAP (NOT SUPPLIED), A RUNNING TRAP IS NOT RECOMMENDED FOR THIS PRODUCT.
  5. A WATER SUPPLY OF MINIMUM 1.0 Bar IS REQUIRED FOR CONNECTION TO THE WATER INLET ON THE FRONT OF THE UNIT. THE SUPPLY IS TO BE ROUTED THROUGH THE PROVIDED ISOLATOR VALVE.
  6. THE CONTROL MODULE IS SUPPLIED WITH A 2 METER CABLE WITH EXPOSED ENDS FOR CONNECTION TO A 230v AC 50Hz 13Amp ELECTRICAL SUPPLY.
  7. THE WATER HEATER SUPPLIED WITH 0.7M FLYING LEAD TO BE INSTALLED INTO A SEPARATE 230v AC 50Hz 13Amp FUSED SPUR AS PER ZIP ES3 MANUAL.
  8. FULL INSTALLATION DETAILS CAN BE FOUND IN THE PSH_30 PRODUCT MANUAL SUPPLIED WITH THIS PRODUCT.
  9. THE FASCIA CAN CAN BE MOUNTED IN WALLS BETWEEN 13mm AND 175mm THICK. LONGER STUD BARS CAN BE PURCHASED FOR INSTALLATION INTO THICKER WALLS.
  10. ENSURE 100mm CLEARANCE ABOVE THE AIR INTAKE TO ENSURE ADEQUATE AIRFLOW TO THE UNIT.

Overview

NOTE: THIS SHEET PROVIDES AN INSTALLATION OVERVIEW FOR REFERENCE ONLY. FOR FULL DETAILS REFER TO THE PRODUCT MANUAL.
Overview
INSTALL THE FASCIA INTO WALL
Overview
INSTALL HOSES AND CABLES TO FASCIA
Overview
FIX ENGINE TO MOUNTING BRACKETS ADDITIONAL SPACE BRACKETS ARE PROVIDED FOR WALLS LESS THAN 120mm THICK
Overview

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Wallgate User Manuals

Related Manuals