Autonics TCD210216AD SFL Series Safety Cat.4 Detection Safety Light Curtain Instruction Manual

June 10, 2024
Autonics

Safety Cat. 4, Finger/Hand/Body Detection
Safety Light Curtains
SFL / SFLA Series
INSTRUCTION MANUAL
TCD210216AD

TCD210216AD SFL Series Safety Cat.4 Detection Safety Light Curtain

Thank you for choosing our Autonics product.
Read and understand the instruction manual and manual thoroughly before using the product.
For your safety, read and follow the below safety considerations before using.
For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website.
Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice.
Follow Autonics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • symbol indicates caution due to special circumstances in which hazards may occur.

Warning Failure to follow instructions may result in serious injury or death.

  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in personal injury, economic loss or fire.
  2. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in explosion or fire.
  3. Do not connect, repair, inspect, or replace the unit while connected to a power source. Failure to follow this instruction may cause malfunction or danger due to the safety- related function that does not operate properly. For more information, please refer to laws, regulations and standards in the country or region.
  4. Do not disassemble or modify the unit. Failure to follow this instruction may result in personal injury or fire. In addition, the manufacturer does not guarantee the performance and functionality.
  5. After 3 seconds of power input, use a machine or mechanical system. Failure to follow this instruction may cause malfunction or danger due to the safety- related function that does not operate properly.
  6. Responsible person for use is an operator who: – is fully knowledgeable about the installation, settings, use and maintenance of the product. – is familiar with the requirements of laws, regulations and standards in the country or region where the product is installed and used. Responsible person for use has an obligation to educate the requirements to machine users. Machine users are persons who have been fully trained by the responsible person for use and can operate the machine correctly. When any error occurs during the operation of the machine control system, they have a responsibility to report it to the responsible person for use immediately. If an unqualified person operates the product, it may result in personal injury, economic loss or fire.
  7. Qualified personnel shall carry out installation, configuration and combination with the machine control system. If an unqualified person carries out installation, configuration and combination with the machine control system, it may cause malfunction or result in accidents due to undetected human body.
  8. Make sure that only the responsible person uses the keys or tools for accessing and setting the light curtains. Failure to follow this instruction may cause malfunction or result in accidents.
  9. SFL□-□-A models acquire KCs certification as an industrial robot protection device. Do not use it for any other purposes.
  10. When the machine is not operating after installation, check that functions and settings of the product operate correctly as you intended. Failure to follow this instruction may result in personal injury due to undetected human body.
  11. Always make sure that the safety distance between the light curtain and the hazardous part (hazardous zone or hazardous source) of the machine. The machine may not stop before an operator reaches the hazardous zone so that it may result in personal injury. For more information on the safety distance, please refer to laws, regulations and standards in the country or region.
  12. To access the hazardous part (hazardous zone or hazardous source) of the machine, you shall install the light curtain as human body passes through the detection zone. If the hazardous part of the machine is accessible beyond the detection zone, install additional guards. In addition, when working in the hazardous zone, make sure that a part of human body is within the detection zone. If the installation does not detect the human body, it may result in personal injury.
  13. Do not arrange or use the light curtain as a reflective or retroreflective type with reflector. If the installation does not detect the human body, it may result in personal injury.
  14. Do not use the light curtain to detect flying objects toward the detection zone. If there is a risk, take additional safety measures, such as installing an additional safety guard.
  15. The auxiliary output (AUX) is non-safety output, therefore, do not use it for safety purposes. Failure to follow this instruction may result in serious injury because the safety cannot be guaranteed.
  16. The lamp output (Lamp) is non-safety output, therefore, do not use it for safety purposes. Failure to follow this instruction may result in serious injury because the safety cannot be guaranteed.
  17. Only qualified personnel shall use the PC setting tool (alight Curtain) to configure functions of light curtain and manage the changed settings. If an unqualified person tries to change settings of function via the PC setting tool, it may cause malfunction or result in personal injury due to undetected human body.
  18. After setting or changing the function of light curtain via the PC setting tool, check that light curtain operates as you intended. Failure to follow this instruction may result in personal injury.
  19. When installation, if you have changed the configuration of light curtain (replacement of light curtain, change the number of beams, change the number of series connection, etc.), set the function of the light curtain via the PC setting tool again. Failure to follow this instruction may result in personal injury due to unintended settings.
  20. If the (master) receiver has been replaced, send the setting information of PC setting tool to the replaced receiver gain. Failure to follow this instruction may result in personal injury due to unintended settings.
  21. Install the devices for releasing Interlock condition (e.g. switch) in a location where the entire hazardous zone can be seen or the devices cannot be handled within the hazardous zone.
  22. When restarting the machine in interlock condition, make sure that no operators are in the hazardous zone. Failure to follow this instruction may result in personal injury due to undetected human body.
  23. Follow the requirements described in this manual for the muting devices and installation method to use muting function. For more information, please refer to laws, regulations and standards in the country or region. Failure to follow these requirements, the functions and performance are not guaranteed. It may result in personal injury.
  24. Install the muting devices in a location that can be changed by only qualified and responsible person for use. Change the installation location under the supervision of responsible person for use.
  25. The muting function temporarily stops the safety related functions of light curtain. If the function is activated, take additional safety measures for the safety of the machine control system.
  26. When the muting function is activated, make sure that no operator is in the hazardous zone. Take additional safety measures to prevent the human body from entering the hazardous zone.
  27. When you need to inform that the muting function is activating, install the indicators with any forms (e.g. alarm lamp) where it can be seen from all sites. For more information, please refer to laws, regulations and standards in the country or region.
  28. Qualified and responsible person for use should conduct the risk assessment on the time related to the muting function, set the time correctly according to the conditions described in this manual. In particular, set the muting timeout (T2) to a finite value in the PC setting tool. Failure to follow this instruction may cause the function failure of safety related and result in personal injury or fire.
  29. When you use the auto scan for muting zone via PC setting tool, the OSSD output may temporarily go to ON state due to the operation of line or facilities for scan and measurement. Therefore, safety measures in workplace shall be implemented. If there is a risk, take additional safety measures, such as installing an additional safety guard.
  30. The installation environment and timing chart shown in the PC setting tool are examples for your understanding. Make sure that the qualified and responsible person for use check the light curtain operates in the actually installed site as intended. Failure to follow this instruction may result in personal injury due to undetected human body.
  31. Follow the requirements described in this manual for the devices and installation method to use the override function. For more information, please refer to laws, regulations and standards in the country or region. Failure to follow these requirements, the functions and performance are not guaranteed. It may result in personal injury.
  32. Connect the override switch to reset input to use the override function. Failure to release the override condition with the override switch may result in personal injury.
  33. The override function temporarily stops the safety related functions of light curtain. Therefore, safety measures in workplace shall be implemented. If the function is activated, take additional safety measures for the safety of the machine control system.
  34. When the override function is activated, make sure that no operator is in the hazardous zone. Take additional safety measures to prevent the human body from entering the hazardous zone.
  35. When you need to inform that the override function is activating, install the indicators with any forms (e.g. alarm lamp) where it can be seen from all sites. For more information, please refer to laws, regulations and standards in the country or region.
  36. Qualified and responsible person for use should conduct the risk assessment on the time related to the override function, set the time correctly according to the conditions described in this manual. In particular, set the override timeout to a finite value in the PC setting tool. Failure to follow this instruction may cause the function failure of safety related and result in personal injury or fire.
  37. After setting the fixed blanking function, check that it operates as intended. Failure to follow this instruction may result in personal injury due to undetected human body.
  38. If the tolerance is set for the fixed blanking function, the detection capability will be larger. Calculate the safety distance suitable for the minimum detection capability to secure minimum safety distance.
  39. If you use the fixed blanking function, conduct additional safety measures to prevent a part of human body from entering the hazardous zone passing by beams for the blanking zone.
  40. After setting the floating blanking function, check that it operates as intended. Failure to follow this instruction may result in personal injury due to undetected human body.
  41. If the tolerance is set for the floating blanking function, the detection capability will be larger. Calculate the safety distance suitable for the minimum detection capability to secure minimum safety distance.
  42. If you use the floating blanking function, conduct additional safety measures to prevent a part of human body from entering the hazardous zone passing by beams for the blanking zone.
  43. If you use the auto scan function for the fixed and floating blanking zone via the PC setting tool, the OSSD output temporarily goes to the OFF state. Please note that the operating status of the light curtain may be changed.
  44. If you use the reduced resolution function, the detection capability will be larger. Calculate the safety distance suitable for the minimum detection capability to secure minimum safety distance.
  45. Only qualified and responsible person for use shall use the factory reset via the PC setting tool. Also, check the safety distance and the operation of the light curtain again. Failure to follow this instruction may result in personal injury due to undetected human body.
  46. Check ‘Connections’ before wiring. And make sure that there are no safety problems. Failure to follow this instruction may result in fire.
  47. When using PNP output, be sure to connect the load between the OSSD output wire and 0V. Do not short the OSSD output wires to +24V. Incorrect wiring or shut down of the power supply is dangerous because the OSSD output is always in ON state.
  48. When using NPN output, be sure to connect the load between the OSSD output wire and +24V. Do not short the OSSD output wires to 0V. Incorrect wiring or shut down of the power supply is dangerous because the OSSD output is always in ON state.
  49. Use only the two OSSD output wires in this product to construct safety systems, and do not use output signals (e.g. auxiliary output) other than the OSSD output for safety purposes. When you use only one OSSD output or use other output signal as a safety output, the machine cannot be stopped in the event of a malfunction and result in personal injury due to the safety related function failure.
  50. When wiring, all input/output wires with double insulation or reinforced insulation should be used between the circuits. Failure to follow this instruction may result in fire.
  51. Do not install all input/output wires in the same piping with high voltage wire and power line. Failure to follow this instruction may cause malfunction or dangerous due to the safety related function do not operate properly.
  52. Use a separate power supply for the load and the product, and do not exceed the specified ratings. Failure to follow this instruction may result in damage or malfunction of the product.

Caution Failure to follow instructions may result in injury or product damage

  1. Use the product within the rated specifications. Failure to follow this instruction may result in fire or product damage.
  2. Use a dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in fire.
  3. Use the cable within the rated length and do not modify, change, and extend the cable. If the cable is longer, it may cause malfunction or dangerous due to the safety related function do not operate properly.
  4. To use the light curtain in “PSDI mode”, configure the appropriate control circuit between the light curtain and the machine according to the requirements of laws, regulations and standards in the country or region.
  5. Do not use the product outdoors. Failure to follow this instruction may result in damage and malfunction of the product.
  6. Keep the product away from metal chip, dust, and wire residue which flow into the unit. Failure to follow this instruction may result in personal injury due to the malfunction of the light curtain.
  7. Be sure for responsible person for use to change the password of PC setting tool to prevent the setting change by the machine users (or operator). Securely manage your password and avoid forgetting the password. Failure to follow this instruction may result in personal injury due to the malfunction of the light curtain.
  8. You must conduct regular inspections and maintenance procedures according to the items listed on the “Check and Maintenance” within six months. Failure to follow this instruction may result in personal injury due to the malfunction of the light curtain.
  9. Check the installation status, normal operation, breakage, modification, and manipulation in the situations shown below, and conduct the weekly inspection.
    – When starting the safety system for the first time
    – When replacing the accessories of the safety system
    – When the safety system has not been operated for a long time Failure to follow this instruction may result in personal injury because the safety- related function may not work properly due to the malfunction of the product.

Cautions for Installation

For more information, refer to the “SFL/SFLA User Manual.”

  • Install the unit correctly with the usage environment, location, and the designated specifications. Install the light curtain that complies with the following details.

    • Part(s) of the human body passes through the detection zone to the hazards of the machine.
    • Install an additional guard if part(s) of the human body access to hazards of the machine without passing through the detection zone.
    • If an operator works in the hazardous part of the machine, be sure to install the light curtain to detect part(s) of the human body.
  • You must set the safety distance of the light curtain.
    Failure to this instruction, the machine cannot be stopped before reaching the hazardous part, and it may result in personal injury.
    The safety distance calculation may differ from laws, regulations, and standards. Therefore, be sure to use the appropriate formula which abides by the rules of the country.

  • Install the emitter and the receiver face to each other and adjust the top and bottom beam of the light curtain to meet the centerline. Also, the switch settings of the emitter and the receiver must be the same.

  • Be sure to apply the power to both the emitter and the receiver at the same time.
    If not, the product enters the lockout condition, and the red and green LED of the upper OSSD indicators flash alternately.

  • Use a bracket suitable for the mounting method.
    The type and number of brackets differ depending on the length of the light curtain.

Cautions during Use

  • Follow instructions in “Cautions during Use”. Otherwise, it may cause unexpected accidents.

  • The power input of 24VDC   model is insulated and limited voltage/current or supply via power supply with SELV and Class 2.

  • When supplying power with SMPS, ground the F.G. terminal and connect the noise suppression capacitor between 0V and F.G. terminal.

  • Be sure to use separate F.G. between the product and equipment with a strong noise (welding machine). The same F.G. may result in malfunction.

  • When installing the light curtain, make sure that the bottom indicators of the emitter and receiver are aligned exactly.

  • Install the light curtain in a place where the emitter and receiver are not affected by walls or reflecting surfaces.

  • If you use the light curtain as several sets, arrange them not to interfere with each other, or install with a shading plate.

  • Do not install the light curtain in place where it is exposed to intense disturbance light (such as direct sunlight, sunlight, spotlights fluorescent lights, and etc.) or reflected light from glossary surface is directly incident on the receiver. If it is difficult to install in such a place, take additional safety measures using shading plates, hoods, etc.
    Failure to follow this instruction may cause malfunction or dangerous due to the safety related function do not operate properly.

  • Make sure that any unused wires, when installing the product, should be insulated.

  • Make sure that removable parts (including packing, end caps, product wires, covers, etc.)
    are properly assembled. Also, tighten the screws with specified tightening torque. Failure to follow this instruction may cause product degradation.

  • Assessment of conformity to the required safety level is evaluated for the entire system.
    Please consult with a certified certification body regarding the assessment procedure.

  • It should be done away regarded as an industrial waste. For more information, please refer to laws, regulations and standards in the country or region.

  • This product may be used in the following environments.
    – Altitude max. 2000 m
    – Pollution degree 3
    – Installation Category Ⅱ

Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
SFL ❶ ❷ – ❸ – ❹

  1. Type
    No-mark: Standard type
    A: Advanced type

  2. Detection capability
    14: Ø 14 mm, finger
    20: Ø 20 mm, hand
    30: Ø 30 mm, hand-body

  3. Number of optical axes
    Number: Number of optical axes

  4. Korea safety certification
    No-mark: S-mark
    A: KCs (industrial robot protection device)

Product Components

  • Product
  • Instruction manual

Manual
For proper use of the product, refer to the manuals and be sure to follow the safety considerations in the manuals.
Download the manuals from the Autonics website.
Dimensions

  • Unit: mm, For the detailed drawings, follow the Autonics website.
  • This dimension is based on the SFL(A) 14 model. The appearance varies depending on the detection capability.
  1. When removing the end cap, there is the lamp output terminal (top) or the power supply terminal (bottom).
  2. When removing the front cover, there is the setting switch (on the emitter and the receiver) or the PC communication port (on the receiver).

Detection capability| Models| Number of beams| A (protective height)| B (sensing height)| C (optical axis pitch)
---|---|---|---|---|---
Ø14 mm (finger)| Standard| 15 to 111| 144 to 1,008| 126 to 990| 9
Advanced| 15 to 199| 144 to 1,800| 126 to 1,782
Ø20 mm (hand)| Standard| 12 to 68| 183 to 1,023| 165 to 1,005| 15
Advanced| 12 to 124| 183 to 1,863| 165 to 1,845
Ø30 mm (hand-body)| Standard| 42 to 75| 1,043 to 1,868| 1,025 to 1,850| 25
Advanced| 9 to 75| 218 to 1,868| 200 to 1,850

Sold Separately

  • Power I / O cable
    : SFL-BCT(R) (connector type), SFL-C□T(R) (cable connector type)

  • Connector cable
    : CID8-□T(R) (socket type), C1D8-□T(R) (socket-plug type)

  • Y type connector cable: SFL-YC, SFL-YCR

  • Series connector cable: SFL-EC□T(R)

  • Lamp output cable: SFL-LC

  • Bracket: BK-SFL- □ (Top/Bottom (adjustable), Side (adjustable))

  • SFL / SFLA dedicated USB to Serial communication converter: SCM-SFL

  • Test piece: SFL-T□

  • LOTO (Lockout-Tagout) device: SFL-LT□

Specifications

Type Standard type
Models SFL14-□-□
Sensing type Through-beam
Light source Infrared LED (855 nm)
Effective aperture angle (EAA) Within ± 2.5 ° when the sensing distance is

greater than 3 m for both emitter and receiver.
Sensing distance| Short – Long mode (setting switch)
Short mode| 0.2 to 5 m| 0.2 to 8 m| 0.2 to 8 m
Long mode| 0.2 to 10 m| 0.2 to 15 m| 0.2 to 15 m
Detection capability| Ø14 mm (finger)| Ø20 mm (hand)| Ø30 mm (hand-body)
Detection object| Opaque object
Number of optical axes 01)| 15 to 111| 12 to 68| 42 to 75
Protective height| 144 to 1,008 mm| 183 to 1,023 mm| 1,043 to 1,868 mm
Optical axis pitch| 9 mm| 15 mm| 25 mm
Series connection| Max. 3 SET (≤ 300 optical axes)
Type| Advanced type
---|---
Models| SFLA14-□-□| SFLA20-□-□| SFLA30-□-□
Sensing type| Through-beam
Light source| Infrared LED (855 nm)
Effective aperture angle (EAA)| Within ± 2.5 ° when the sensing distance is greater than 3 m for both emitter and receiver.
Sensing distance| Short – Long mode (setting switch or curtailment)
Short mode| 0.2 to 5 m| 0.2 to 8 m| 0.2 to 8 m
Long mode| 0.2 to 10 m| 0.2 to 15 m| 0.2 to 15 m
Detection capability| Ø 14 mm (finger)| Ø 20 mm (hand)| Ø 30 mm (hand-body)
Detection object| Opaque object
Number of optical axes 01)| 15 to 199| 12 to 124| 9 to 75
Protective height| 144 to 1,800 mm| 183 to 1,863 mm| 218 to 1,868 mm
Optical axis pitch| 9 mm| 15 mm| 25 mm
Series connection| Max. 4 SET (≤ 400 optical axes)

  1. It may differ depending on the models. For more information, refer to the “SFL/SFLA User Manual.”
Power supply 24 VDC ± 20 % (Ripple P-P: ≤ 10 %)
Current consumption 01) Emitter: ≤ 106 mA, receiver: ≤ 181 mA
Response time 01) TOFF (ON → OFF): ≤ 32.3 ms, TON (OFF → ON): ≤ 76.6 ms
Safety related output : OSSD output NPN or PNP open collector

Load voltage 02): ON – 24 VDC (except for the residual voltage), OFF – 0 VDC ,
Load current 03): ≤ 300 mA, Residual voltage 04): ≤ 2 VDC (except for voltage drop due to wiring), Load capability: ≤ 2.2 ㎌, Leakage current: ≤ 2.0 mA, Wire resistance of load: ≤ 2.7 Ω
Auxiliary output (AUX 1/2) 05)| NPN or PNP open collector
Load voltage: ≤ 24 VDC , Load current: ≤ 100 mA, Residual voltage: ≤ 2 VDC (except for voltage drop due to wiring)
Lamp output (LAMP 1/2) 05)| NPN or PNP open collector Load voltage: ≤ 24 VDC , Load current: ≤ 300 mA
External input| Reset input, mute 1/2 input, EDM, external test
When setting NPN output
ON: 0 – 3 VDC , OFF: 9 – 24 VDC or open, short-circuit current: ≤ 3 mA When setting PNP output ON: 9 – 24 VDC , OFF: 0 – 3 VDC or open, short-circuit current: ≤ 3 mA
Protection circuit| Reverse power polarity, reverse output polarity, output short-circuit over-current protection
Safety-related functions| Interlock (reset hold), external device monitoring (EDM), muting/override, Blanking (fixed blanking, floating blanking), reduced resolution
General functions| Self-test, alarm for reduction of incident light level, mutual interference prevention
Others functions| Change of sensing distance, switching to NPN or PNP, external test (light emission stops), auxiliary output (AUX 1, 2), lamp output (LAMP1, 2)
Synchronization type| Timing method by RS485 synchronous line
Insulation resistance| ≥ 20MΩ (at 500 VDC megger)
Noise immunity| ± 240 VDC the square wave noise (pulse width: 1μs) by the noise simulation
Dielectric strength| 1,000 VAC 50 / 60 Hz for 1 minute
Vibration| 0.7 mm double amplitude at frequency of 10 to 55Hz, 20 sweeps in each X, Y, Z direction
Shock| 100 m/s2 (≈ 10 G), pulse width 16 ms in each X, Y, Z direction for 1,000 times
Ambient illumination (receiver)| Incandescent lamp: ≤ 3,000 lx, sunlight: ≤ 10,000 lx
Ambient temperature| -10 to 55 ℃, storage: -20 to 70 ℃ (no freezing or condensation)
Ambient humidity| 35 to 85 %RH, storage: 35 to 95 %RH (no freezing or condensation)
Protection rating 06)| IP65, IP67 (IEC standard), IP67G (JEM Standard), IP69K (DIN standard)
Material| Case: Aluminum, Front cover and sensing part: Polymethyl methacrylate, End cap: polycarbonate, Power I/O cable and connector cable: polyurethane (PUR) or polyvinyl chloride (PVC), Y type connector cable: polyvinyl chloride (PVC), lamp output cable and series connector cable: polyurethane (PUR), Top / Bottom adjustable bracket and Top / Bottom bracket: SUS304,Side adjustable bracket and Side bracket: nickel plated Zn
Approval|  (industrial robot protection device) 07)
International standards| UL 508, CSA C22.2 No. 14, ISO 13849-1 (PL e, Cat. 4), ISO 13849-2 (PL e, Cat. 4), UL
61496-1 (Type 4, ESPE), UL 61496-2 (Type 4, AOPDs), IEC/EN 61496-1 (Type 4, ESPE),
IEC/EN 61496-2 (Type 4, AOPDs), IEC/EN 61508-1~-7 (SIL 3), IEC/EN 62061 (SIL CL 3)

Setting Switch

No. Function Settings (marks in the sticker)
ON OFF (factory default)
1 NPN or PNP NPN
2 Sensing distance Short mode (S)
3 Frequency Frequency B (FREQ B)
4 Reset-hold Reset-hold (R-H)
5 Interlock Manual reset (MAN)
6 EDM EDM
7 Muting MUTE
8 Apply settings alight Curtain (PC)
  • Remove the front cover of the light curtain and set functions via the setting switch.
  • Be sure to select the same settings of emitter and receiver. (factory defaults: OFF)
  • For more information, refer to the “SFL/SFLA User Manual.”

7-segment Display

Operation Position Display Description
Emitter/ Receiver PC connection (download) P Flashing

downloading the setting information.
Communication error| C| Flashing| Flashes when RS485 communication error occurs.
Error condition| E| Flashing| Flashes when entering the lockout condition.
Warning condition| | Flashing| Flashes when in a warning condition.
Emitter| Default condition| 0| ON| Displays when function is deactivated.
Blanking| B| ON| Displays when the blanking function is activated.
Muting| M| ON| Displays when in the muting state.
Override| O| ON| Displays when in the override state.
Reset-hold| | ON| Displays when waiting for reset-hold input.
Reduced resolution| R| ON| Displays when the reduced resolution function is activated.
Receiver| Light incident| to| ON| Displays the sensitivity level of beams with the lowest light incident (0 to 9).

  • This table shows the display during operation.
  • For more information on the display of power on and error condition, refer to the “SFL/SFLA User Manual.”

Brackets Installation

Top/Bottom adjustable bracket (BK-SFL-TBA) Top/Bottom bracket (BK-SFL-TBF)
Side adjustable bracket (BK-SFL-SA) Side bracket (BK-SFL-SF)
  • Tighten the product fixing bolts with a torque of 0.98 N m.
  • The type and number of brackets differ depending on the length of the light curtain.
Length Brackets Max. 1 m Min. 1 m
Top/Bottom adjustable bracket 2 Unavailable

Top/Bottom bracket
Side adjustable bracket| 2| 3

  • For more information, refer to the “SFL/SFLA User Manual.

Example of Wiring Diagram

The wiring varies depending on the functions you use.
For more information, refer to the “SFL/SFLA User Manual.”
If there is a potential malfunction due to noise, combine a protection circuit to the input wiring, or connect a device with a protection circuit and apply the signal.
NPN output

![Autonics TCD210216AD SFL Series Safety Cat.4 Detection Safety Light Curtain

PNP output

![Autonics TCD210216AD SFL Series Safety Cat.4 Detection Safety Light Curtain

  • Diagram1](https://manuals.plus/wp-content/uploads/2023/04/Autonics- TCD210216AD-SFL-Series-Safety-Cat.4-Detection-Safety-Light-Curtain- Diagram1.jpg)

    1. This wiring is used to activated the lamp output and displays the status to the external indicator based on selected output mode.
    2. RS485(A) and RS485(B) are for the synchronous line.

Check and Maintenance

You must conduct regular inspections within six months, according to the items listed on the checklist. Or it may result in personal injury due to the malfunction of the light
curtain. The checklist before the installation is the table below. For the checklist after the installation, refer to the “SFL/SFLA User Manual.”
Check installation conditions

No. Checklist Check
1 Installed that the machine or additional safety measures (e.g., extra
guards) do not cover the detection zone.
2 Accessible to hazardous zone or source of the machine only by passing
through the detection zone.
3 Available to detect parts of the body when the operator works in hazardous
zone or source of the machine.
4 The distance from hazardous zone or source of the machine to the installed

location of light curtain is equal to, or greater than the calculated safety distance. ※Safety distance: ( )mm / Actual distance: ( )mm|
5| If lustered objects or reflective surfaces are around, the light curtain is installed at a distance over the allowable installation distance.|
6| Installed in a place without the influence of inverter disturbance light (e.g., a fluorescent lamp).|
7| Installed in a place that no material causes deformation in a front window, such as corrosion or ignition.|
8| In use of the interlock function, the reset switch is installed in a position where the entire hazardous zone is visible and cannot be used in the hazardous zone.|
9| In use of the reset hold function, the reset hold switch is installed in a position that cannot be used in the hazardous zone.|
10| The installed emitter/receiver in a single or series connection matches the same specification (function, detection capability, number of optical axes).|
11| In case of the brackets, it is secured to prevent separation during use.|
12| No scratches or damages on the front window of the emitter/receiver.|
13| In use of the muting function, the muting sensors consist of two separate devices.|
14| In use of the muting function, the muting sensor meets the specific conditions to start muting.|
15| In use of the override function, the override starts when the specific conditions are met.|
16| In use of the muting and override functions, install the indicators with any forms (e.g., alarm lamp) where it can be seen from all sites.|
17| In use of the fixed blanking function, it is set to prevent the operator from entering the blanking zone.|
18| In use of the floating blanking or reduced resolution function, the installed light curtain has a distance that equal to or greater than a safety distance calculated by the changed detection capability (diameter).
※Safety distance: ( )mm / Actual distance: ( )mm|

Check wiring connection

No. Checklist Check
1 The power supply used for the product and safety-related devices (e.g.,

muting sensors) is 24VDC , and it meets the rated specifications and not connected to other devices or equipment.|
2| When connecting power supply, the polarity is not connected in reverse.|
3| The appearance of the wires connected to the product is not damaged, such as cracks, breakage of the outer shell. And there are no sources for damage around the wiring.|
4| In case of connecting more than two products, it is configured to use dedicated series connection cable and mutual interference prevention.|
5| In case of the series connection for more than two products, use dedicated series connection cable, and it is configured not to be extended or arbitrarily connected.|
6| The wiring is suitable for each application and is configured not to be connected upper side of the product (e.g., wiring for the series connection cable and lamp output cable) and the lower side of the product (e.g., the power I/O cable) in reverse.|
7| The wiring and end cap connected to the product are firmly secured to prevent separation during use.|
8| The product is connected to the safety-related part of the control system using two OSSD control outputs and configures the safety system.|
9| In case of the product is set to PNP output, two OSSD wires are not shorted to +24V.|
10| In case of the product is set to PNP output, the load connected to two OSSD wires is connected between the OSSD wire and 0V.|
11| In case of the product is set to NPN output, two OSSD wires are not shorted to 0V.|
12| In case of the product is set to NPN output, the load connected to two OSSD wires is connected between the OSSD wire and +24V.|
13| In case of the auxiliary output (AUX 1/2, Lamp 1/2), it is configured to prevent the connection to the safety-related part of the control system.|
14| The power I/O cable is connected with its direction of protrusion towards the outside.|

Software

Download the installation file and the manuals from the Autonics website.
curtailment
It is that provides configuration and monitoring of light curtain.
In case of SFL (Standard type), only monitoring function is supported, and in case of SFLA (advanced type), all functions such as parameter setting are available.

18, Ban song 513Beon-gil, Sundae, Busan, Republic of Korea, 48002
www.autonics.com
+82-2-2048-1577
sales@autonics.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Autonics User Manuals

Related Manuals