Altronix PD8 Power Distribution Modules Instruction Manual
- June 4, 2024
- Altronix
Table of Contents
PD8/PD8CB
Power Distribution Modules
Overview:
Altronix PD8/PD8CB power distribution modules convert a single AC or DC input into eight (8) individually fused or PTC-protected outputs.
Specifications:
Input:
- 28VAC or 28VDC max., up to 10A.
Outputs:
- PD8: Eight (8) individually fused outputs (fuses are rated @ 3.5A; up to 5A fuses may be used).
- PD8CB: Eight (8) PTC protected auto-resettable outputs (PTCs are rated @ 2.5A).
- Surge suppression.
Main Fuse Ratings:
- The main fuse is rated @ 5A/250V.
Visual Indicators:
- Power output LED indicator.
Additional Features:
- Power the ON / OFF switch.
Board Dimensions (L x W x H, approximate): 5.25” x 3.25” x 1” (133.4mm x 82.6mm x 25.4mm).
Installation Instructions:
-
Mount PD8/PD8CB in the desired location/enclosure (mounting hardware included).
-
Connect the desired power supply output to terminals marked [INPUT] (Fig. 1a).
Note: If using DC voltage, the left terminal is NEG. (–) and the right terminal is POS. (+) (Fig. 1a). -
Measure output voltage before connecting devices. This helps avoid potential damage. All terminals with the common suffix P “1P, 2P…” are the same polarity.
-
Set the power switch [SW1] to the OFF position.
-
Connect each device to the terminal pairs 1 to 8, marked [1P – 1N] through [8P – 8N].
-
PD8 output fuses are rated at 3.5A/250V (Replacement fuses can be rated at up to 5.0A).
-
Set the power switch [SW1] to the ON position.
Altronix is not responsible for any typographical errors.