Kramer BCLS-33 CAT 6A F/UTP LSZH Bulk Cable Owner’s Manual

June 10, 2024
Kramer

Kramer BCLS-33 CAT 6A F/UTP LSZH Bulk Cable

Kramer-BCLS-33-CAT-6A-F-UTP-LSZH-Bulk-Cable-fig-1

Product Information

The BCLS-33 is a high-performance CAT 6A F/UTP cable designed for IT, LAN, and Ethernet installations. This cable is constructed with 23AWG solid bare copper conductors with cross filler, and overall metal foil screen with a drain wire. It is enclosed in an LSZH jacket with sequential markings every meter and packed on a fumigated plywood reel. The BCLS-33 cable exceeds CAT 6A specifications to provide additional performance and bandwidth beyond the basic standard.

Features

  • High-Performance Transmission
  • High-Quality Safety Properties
  • Sweep Frequency up to 650MHz
  • Length – Available in length of 500m (1640ft)

Technical Specifications

Construction

  • Conductor: 4 pairs of 23AWG solid bare copper
  • Insulation: Polyolefin (PO); blue & white/blue stripe, orange & white/orange stripe, green & white/green stripe, brown & white/brown stripe
  • Twist: Left-hand
  • Assembly: Left-hand direction
  • Rip Shield: Mylar tape
  • Drain Wire: 24AWG solid tinned copper
  • Shield: Al Mylar tape, 100% coverage, and mylar side facing out
  • Jacket: Low smoke zero halogen (LSZH), orange (Pantone 1485C)
  • Filler: Polyolefin (PO)

Diameters

  • Overall Diameter: 7.5mm ± 0.2mm

Electrical

  • Spark Test: 2.5kV DC
  • AC Leakage Current: 10mA (1.5kV AC) through overall jacket
  • Conductor DC Resistance: 9.38 /100m
  • Resistance Unbalance: 5%
  • Dielectric Strength : 1.5kV AC for 2sec
  • Insulation Resistance: 5000M /m
  • Mutual Capacitance: 5.6nF /100m
  • Capacitance Unbalance: 330pF /100m pair-to-ground
  • Coupling Attenuation: 55dB @30MHz, 41dB @500MHz

Usage and Environmental

  • Insulation Tensile Strength: 2400 PSI min. (1.69kg/m.sq)
  • NVP 67%
  • Minimum Bending Radius: 4 times of overall diameter
  • Maximum Pulling Tension: 110N

Regulatory Performance

  • ANSI/TIA-568-C.2 (2009): Balanced Twisted-Pair Telecommunications Cabling and Components Standards
  • EN 50173-1:2011

Regulatory Safety

  • ISO/IEC 11801 (Edition 2.2): Information technology – Generic cabling for customer premises
  • IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications – Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz – Horizontal floor wiring – Sectional specification
  • EN 50288-6-1:2013: Multi-element metallic cables used in analogue and digital communication and control – Part 6-1: Sectional specification for unscreened cables characterized up to 250MHz – Horizontal and building backbone cables
  • IEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions – Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1kW pre-mixed flame
  • IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions
  • IEC 60754-2 Test on gases evolved during combustion of materials from cables
  • EU Directive 2011/65/EC (RoHS 2)
  • EU Directive 2006/95/EC (LVD)
  • CE compliance date: 2010.01.01

Configurations

  • BCLS-33OR-5 – CAT 6A F/UTP LSZH Bulk Cable – Orange

Product Usage Instructions

  • The BCLS-33 is designed for IT, LAN, and Ethernet installations. It is suitable for use in horizontal and backbone cabling applications up to 1000 MHz. The cable is suitable for use in low smoke zero halogen environments that require a higher level of safety.
  • The cable can be easily installed using standard cable installation methods. Please note that the minimum bending radius is four times the overall diameter, and the maximum pulling tension is 110N. When installing the cable, ensure that it is not subjected to excessive tension or bending, which could damage the cable and reduce performance.
  • The cable is available in a length of 500m (1640ft) and comes packed on a fumigated plywood reel. The sequential markings every meter make it easy to measure and cut the cable to the desired length.
  • For optimal performance, it is recommended to follow the regulatory performance and safety standards listed in the product information section above.

Kramer’s BCLS−33 is a high−performance CAT 6A F/UTP cable designed for IT, LAN and Ethernet installations. It is constructed with 23AWG solid bare copper conductors with a cross filler and overall metal foil screen with a drain wire. It is enclosed in an LSZH jacket with sequential markings every meter and packed on a fumigated plywood reel. BCLS−33 cable exceeds CAT 6A specifications to provide additional performance and bandwidth beyond the basic standard

FEATURES

  • High-Performance Transmission
  • High-Quality Safety Properties
  • Sweep Frequency up to 650MHz
  • Length – Available in length of 500m (1640ft)

TECHNICAL SPECIFICATIONS

  • CONSTRUCTION
    • Conductor: 4 pairs of 23AWG solid bare copper
    • Insulation: Polyolefin (PO); blue & white/blue stripe, orange & white/orange stripe, green & white/green stripe, brown & white/brown stripe
    • Twist: Left−hand
    • Assembly: Left hand direction
    • Rip Shield: Mylar tape
    • Drain Wire: 24AWG solid tinned copper
    • Shield: Al Mylar tape, 100% coverage and mylar side facing out
    • Jacket: Low smoke zero halogen (LSZH), orange (Pantone 1485C)
  • Filler: Polyolefin (PO)
  • DIAMETERS
    • Jacket:
    • Diameter: 7.6 ±0.2mm;
    • thickness: 0.55 ±0.05mm
    • Insulation: Blue & white/blue stripe: 1.15 ± 0.02mm
    • Orange & white/orange stripe: 1.11 ± 0.02mm
    • Green & white/green stripe: 1.15 ± 0.02mm
    • Brown & white/brown stripe: 1.11 ± 0.02mm
  • ELECTRICAL
    • Temperature & Voltage Rating: 60°C @300V
    • Spark Test: 2.5kV DC
    • AC Leakage Current: ≤10mA (1.5kV AC) through overall jacket
    • Conductor DC Resistance: ≤9.38Ω /100m
    • Resistance Unbalance: ≤5%
    • Dielectric Strength: 1.5kV AC for 2sec
    • Insulation Resistance: ≥5000MΩ /m
    • Mutual Capacitance: ≤5.6nF /100m
    • Capacitance Unbalance: ≤330pF /100m pair−to−ground
    • Characteristic Impedance: 100±15Ω @1~100MHz
    • Coupling Attenuation: ≤55dB @30MHz, ≤41dB @500MHz
  • USAGE AND ENVIRONMENTAL
    • Cable Cold Bend: −20°C for 4hr
    • Insulation Tensile Strength: 2400 PSI min. (1.69kg/m.sq) NVP 67%
    • Temperature Range:
    • Storage & shipping: −20°C to 60°C;
    • installation: 0°C to 60°C;
    • operation: −20°C to 60°C
    • Minimum Bending Radius: ≥4 times of overall diameter
    • Maximum Pulling Tension: ≤110N
  • REGULATORY PERFORMANCE
    • ANSI/TIA-568-C.2 (2009): Balanced Twisted−Pair Telecommunications Cabling and Components Standards
    • ISO/IEC 11801 (Edition 2.2): Information technology − Generic cabling for customer premises
    • IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications − Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz − Horizontal floor wiring − Sectional specification
    • EN 50288-6-1:2013: Multi−element metallic cables used in analogue and digital communication and control − Part 6−1: Sectional specification for unscreened cables characterized up to 250MHz − Horizontal and building backbone cables
  • EN 50173-1:2011
    • Information technology.
    • Generic cabling systems.
    • General requirements
  • REGULATORY SAFETY
    • IEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions − Part 1−2: Test for vertical flame propagation for a single insulated wire or cable − Procedure for 1kW pre−mixed flame
    • IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions
    • IEC 60754-2 Test on gases evolved during combustion of materials from cables
    • EU Directive 2011/65/EC (RoHS 2)
    • EU Directive 2006/95/EC (LVD)
    • CE compliance date: 2010.01.01