Kramer BCLS-45RD-5 CAT 7 S/FTP 23AWG 750MHz Bulk Cable Owner’s Manual
- June 10, 2024
- Kramer
Table of Contents
Kramer BCLS-45RD-5 CAT 7 S/FTP 23AWG 750MHz Bulk Cable
Product Information:
- The BCLS-45RD-5 CAT 7 S/FTP 23AWG 750MHz Bulk Cable is a high-performance transmission cable that offers high-quality safety properties. It has a sweep frequency up to 750MHz, and it comes in wooden drums of 500m (1640ft). The cable features 4 pairs of 23AWG solid bare copper conductors, Polyolefin insulation in blue & white, orange & white, green & white, brown & white colors, left-hand twist, Al Mylar tape shield with 100% coverage and aluminum side facing out, tinned copper braid with 30% coverage, and a Low smoke zero halogen (LSZH) red jacket (Pantone 1797C).
- The BCLS-45RD-5 cable has a spark test of 2.5kV DC, AC Leakage Current of 10mA (1.5kV AC) through overall jacket, Conductor DC Resistance of 9.38 /100m, Resistance Unbalance of 5%, Dielectric Strength of 1.5kV AC for 2sec, Insulation Resistance of 5000M /m, Mutual Capacitance of 5.6nF /100m, and Capacitance Unbalance of 160pF /100m pair-to-ground.
- It has an insulation Tensile Strength of 2400 PSI min. (1.69kg/m,2), NVP 73%, Minimum Bending Radius of 4 times of overall diameter, and Maximum Pulling Tension of 110N. The product is compliant with ISO/IEC 11801 (Edition 2.2), IEC 61156-5 (Edition 2.0), EN 50288-6-1:2013, EN 50173-1:2011, IEC 60332-1-2, IEC 61034-1/61034-2, IEC 60754-2, EU Directive 2011/65/EC (RoHS 2), EU Directive 2006/95/EC (LVD), and CE compliance date: 2010.01.01.
Product Usage Instructions:
- The BCLS-45RD-5 cable is designed for use in generic cabling systems for customer premises, multicore and symmetrical pair/quad cables for digital communications, and multi-element metallic cables used in analogue and digital communication and control. Thecable is suitable for horizontal floor wiring and building backbone cables. It is recommended to use the cable in accordance with the regulatory safety requirements mentioned in the product manual.
- The cable has a minimum bending radius of 4 times of overall diameter and a maximum pulling tension of 110N. It is advised to handle the cable with care during installation and avoid excessive bending or pulling. The product manual also recommends testing the cable’s performance using appropriate testing equipment and methods to ensure it meets the required specifications.
Kramer’s BCLS−45 is a high−performance CAT 7 S/FTP cable designed for IT, LAN and Ethernet installations. It is constructed with 23AWG solid bare copper conductors where each pair is individually shielded with metal foil screen and the entire cable is shielded with a tinned copper braid. It is enclosed in an LSZH jacket with sequential markings every meter and packed on a fumigated plywood reel. BCLS−45 cable exceeds CAT 7 specifications to provide additional performance and bandwidth beyond the basic standard
FEATURES
- High-Performance Transmission
- High-Quality Safety Properties
- Sweep Frequency up to 750MHz
- Length – Available in wooden drums of 500m (1640ft)
TECHNICAL SPECIFICATIONS
- CONSTRUCTION
- Conductor: 4 pairs of 23AWG solid bare copper
- Insulation: Polyolefin (PO); blue & white, orange & white, green & white, brown & white
- Twist: Left−hand
- Shield: Al Mylar tape, 100 % coverage, and aluminum side facing out
- Assembly: Left-hand direction
- Braid: Tinned copper, ˃30 % coverage
- Jacket: Low smoke zero halogens (LSZH), red (Pantone 1797C)
- DIAMETERS
- Jacket: Diameter: 7.7 ±0.2mm; thickness: 0.50 ±0.05mm
- Insulation: Blue & white: 1.33 ± 0.02mm
- Orange & white: 1.30 ± 0.02mm
- Green & white: 1.33 ± 0.02mm
- Brown & white: 1.30 ± 0.02mm
- ELECTRICAL
- Temperature & Voltage Rating: 60°C @300V
- Spark Test: 2.5kV DC
- AC Leakage Current: ≤10mA (1.5kV AC) through overall jacket
- Conductor DC Resistance: ≤9.38Ω /100m
- Resistance Unbalance: ≤5%
- Dielectric Strength: 1.5kV AC for 2sec
- Insulation Resistance: ≥5000MΩ /m
- Mutual Capacitance: ≤5.6nF /100m
- Capacitance Unbalance: ≤160pF /100m pair−to−ground
- Characteristic Impedance: 100±15Ω @1~100MHz
- USAGE AND ENVIRONMENTAL
- Cable Cold Bend: −20°C for 4hr
- Insulation Tensile Strength: 2400 PSI min. (1.69kg/m,2) NVP 73%
- Temperature Range: Storage & shipping: −20°C to 60°C; installation: −0°C to 60°C; operation: −20°C to 60°C
- Minimum Bending Radius: ≥4 times of overall diameter
- Maximum Pulling Tension: ≤110N
- REGULATORY PERFORMANCE
- ISO/IEC 11801 (Edition 2.2): Information technology − Generic cabling for customer premises
- IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications − Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz − Horizontal floor wiring − Sectional specification
- EN 50288-6-1:2013: Multi−element metallic cables used in analogue and digital communication and control − Part 6−1: Sectional specification for unscreened cables characterized up to 250MHz − Horizontal and building backbone cables
- REGULATORY SAFETY
- EN 50173-1:2011: Information technology − Generic cabling systems − Part 1: General requirements
- IEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions −
- Part 1−2: Test for vertical flame propagation for a single insulated wire or cable −
- Procedure for 1kW pre−mixed flame
- IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions
- IEC 60754-2 Test on gases evolved during combustion of materials from cables
- EU Directive 2011/65/EC (RoHS 2)
- EU Directive 2006/95/EC (LVD)
- CE compliance date: 2010.01.01
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>