Calibration & Gravity Compensation

1.1. Calibration
When the power is off, press while pressing
When ‘G-CAL’ is displayed, and then press
Then this calibration mode is started.

No. TITLE DISPLAY KEYBOARD & DESCRIPTION
1 How to enter

2| Program version| | Move to a next step in automatic
3| Maximum capacity| | Initialized value
numeric increase
scale increase /save
4| Minimum division| | decrease / increase
save
5| Setting weight| | Initialized value
numeric increase
scale increase / **save
NB : Setting weight shall be within the range of 10 %~100 % of max. capacity
6| Zero calibration| | Unload the tray and press
7| Span calibration| | Load the weight which was set in step 5 and press
8**| Finish| | Unload the tray and press

1.2. Gravity compensation
When the power is off, press while pressing .
When ‘G-CAL’ is displayed, and then press again.
Then this gravity compensation mode is started.

No. TITLE DISPLAY KEYBOARD & DESCRIPTION
1 How to enter
2 Program version

__

| Move to a next step in automatic

3

|

Calibration location

|

(9.799m/s²)

| Initialized value
numeric increase
scale increase /  save
4| Using location.|
9799
(9.799m/s²)|   Initialized value
numeric increase
scale increase /  save
5| Finish| | Unload the tray and press

If the value is same with , it doesn’t need to compensation set.

1.3. Check message

Code Description
The resolution is set to be exceeded the limit 1/50,000.

Check the resolution.
__

| The balance weight for span calibration is lower than 10%, or greater than 100% of the maximum capacity of the scale.
The weight for span calibration should be within 10%~100% of the maximum capacity of the scale.
| Load cell output is too small or large at span calibration. Check the weight unit and load cell or calibrate with lower resolution.

Wireless Pairing

Step Operation & Description
1 ** _How to enter the pairing mode

_ 1) TCB crane scale
** When the display is off, press    key while pressing key.
When (Firmware version) is displayed, press key. Then,  is displayed.

2) TD3000(2300)F wireless display
Press the        key to power on and immediately press key. And press the key again.
Then,  is displayed.
3) TF-100 controller
When the display is off, press  key while pressing key. When (Firmware version) is displayed, press key. Then,  is displayed.
4) TF-400 controller
Press the    key and press  key at the same time. And then, press  key. Then,  is displayed.
5) TF -200 wireless dongle
Press the [SET] KEY for the 5 seconds with the power on that connected. Then, the green light is blinking.

__ 2| Pairing
When  is displayed at both products, if you press key of TCB crane scale, pairing will finish.
Please check “ ” message at both products. ( IR -200: green light will be turn on)
If ending message is not appear, please repeat the pairing.

Exploded view

TMT CRANE SCALE TCB SERIES High Quality Wheel Load Scale - Exploded
view

No NAME SPEC Q’TY
lion 3ton I 5ton 10ton
1 Shackle 5/8 7/8
2 Hook ass’y 3T
3 bolt M5 x 20 4
4 Spec plate 95 x 40 1
5 bolt M6 x30 4
6 Rivet BLIND 2.5 x 6 2
7 gasket 200x120x3.5 1
8 Battery—cover easy TCBL 1
9 LC CAP 6665×9 IT I 055×9 3T
10 Keypad 169×29(Selection for LCD type or FND type) 1
11 TCB body 215420×135(51) I 10T
13 Front panel 201x121x20 1
14 PCB asaY LCD type or FND type 1
15 Screw Flat head 144×16 10
16 Code—stopper PG7 2
17 LC cover 1T 3T
19 Loedcell CSS3-1T CSS3-3T
20 LC BRK 17 3T
22 Wrench Boll Round Head M10 x 25 2
23 BATTERY PACK TLP-100(LCD type) or TLP-200(FND type) 1
24 BATTERY COVER LCD type or FND type 2
25 Power—cable 02.5×400 1
26 Remocon IR-100 10
27 Adaptor LCD type : 51/.1A .Ø3.5 a FND type : 1241A , 03.5 1

Firmware Update

  1. Install the ‘MPLABX’

  2. Run ‘MPLAB X IDE’

  3. Connect the PICkit3 to PC

  4. Connect as shown in the picture below.
    Aligned the RED wire and arrow mark of PCB, and then combines them.
    TMT CRANE SCALE TCB SERIES High Quality Wheel Load Scale -
Update

  5. Select the HEX file (File – Import – Hex/ELF… (Prebuilt) File)
    SEE ATTACHED VIDEO

  1. Prebuilt Filename: Bring up the HEX file
  2. Family: 16-bit MCUs (PIC24)
  3. Device: PIC24FJ64GA306
  4. Supported Debug Header: None
  5. Hardware Tool: PICkit3
  6. After the above setting, click NEXT ☞ NEXT ☞ Finish.
  1. Set the Project Properties (File – Project Properties) SEE ATTACHED VIDEO
  1. Click PICkit3 in Categories
  2. Option categories: Memories to Program
  3. Preserve Program Memory: Select
  4. Preserve Program Memory Start (hex): 0x0800
  5. Preserve Program Memory End (hex): 0x1FFF
  6. After the above setting, click Apply.
  7. Option categories: Power
  8. Power target circuit from PICkit3: Select
  9. After the above setting, click Apply ☞ OK.
  1. Upgrade firmware SEE ATTACHED VIDEO
  1. Click the Make and Program Device icon.
  2. Confirm the complete message.

Read User Manual Online (PDF format)