Included Parts:

  • Reader, Backplate, Wall Plate
  • 6 Machine Screws ­ QTY 2

  • 6 Self Tapping Screws ­ QTY 2

  • 4-40 Phillips Screw

  • 4-40 Pin-in-Torx Screw

Tools Needed (Not Supplies):

  • Phillips Screwdriver
  • 1″ (25 mm), 1/8″ Drill bits
  • T8 Security Torx Bit (optional for increased tamper detection)
  • 6-32 Tap if required

*These wires are only used in Wiegand mode.
**All wiring methods used shall be in accordance with the National Electrical Code, ANSI/NFPA 70.
Readers must be powered by a compatible UL Listed, power limited, access control panel rated 5­16 VDC.

A. Install the Metal Wall Plate to the Wall/Single Gang box. · Use the provided #6 screws.
B. Wire the Cable to the Control Panel.
C. Attach the Reader to the Wall Plate and Install the Reader Screw. · Follow steps 1 through 3 below to ensure proper alignment. Install either the #4-40 screw or Pin-in-Torx screw at the bottom.

LiftMaster SRDRKP 10-Key Keypad Smart Reader Installation Guide - Install
the Metal Wall Plate to the Wall

LiftMaster SRDRKP 10-Key Keypad Smart Reader Installation Guide - RF
TECHNOLOGIES

NOTE: Do NOT use the Power Supply provided with the CAPXLV or CAPXM to directly power up this reader. It is 24V and will cause damage to the reader.
NOTE: LED Control not available when connected to a CAPXS.
⚠ WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

LiftMaster SRDRKP 10-Key Keypad Smart Reader Installation Guide - Reader
Startup Sequence

Test and Installation Tips

  • Power the reader and verify Reader Start-up Sequence.
  • Present a valid credential, reader should beep, flash Green, and report the credential to the panel.
  • If the Badge is read, but no credential is reported at the panel, verify panel wiring and panel setup.
  • By default, the reader will transmit credential and keypad data in Wiegand communication mode.
  • The reader is always listening for an incoming OSDP message. If a message is received during this period, the reader will automatically switch to OSDP-only communication mode.
  • When connecting the reader to an OSDP panel, connect the green wire to RS485A(TR+), and the white wire to RS485B(TR-).
  • If Green and White wires are connected backwards to an OSDP Panel, the reader will flash red and amber.
  • In OSDP, the default baud rate is 9600 and starts up at Address 0.
  • Reader’s Configuration Part Number (CPN) on the label controls the Smart Card Support information.

Additional technical details and regulatory information can be found through the QR Code at top of the front page

Performance Levels

  • Destructive Attack: I
  • Line Security: I
  • Endurance: IV (125 kHz, 13.56 MHz), I (BLE)
  • Standby Power: I

Approvals EN302291, EN301489, EN300330, IP55, UL294

Patents – US9558377 & US9747738B1
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This telecommunication equipment conforms to NTC technical requirement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1.This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.

LiftMaster SRDRKP 10-Key Keypad Smart Reader Installation Guide – Reader Startup Sequence

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

LiftMaster User Manuals

Related Manuals