SIEMENS 7SR224 Three Phase SDR Recloser

SIEMENS 7SR224 Three Phase SDR
Recloser-product

Overview

SIEMENS 7SR224 Three Phase SDR Recloser-fig-1

Item Description
A MLFB model number
B Ratings label
C Programming port
LED Description
L1 Phase A target
L2 Phase B target
L3 Phase C target
L4 Ground fault target
L5 Sensitive earth fault (SEF) target
L6 Recloser is locked out
L7 AC input power to control cubicle ok
L8 Capacitors charged and system ready to reclose
LED Button

status:
---|---|---|---
L9| F1| Push-to-open recloser| Recloser is OPEN
L10| F2| Push-to-close recloser| Recloser is CLOSED
L11| F3| Push-to-toggle reclose functionality ON/OFF| Reclose functionality is ON
L12| F4| Push-to-toggle hot line tag ON/OFF| Hotline tag is ON
L13| F5| Push-to-toggle ground fault protection ON/OFF| Ground fault protection is OFF
L14| F6| Push-to-toggle SEF protection ON/OFF| SEF protection is OFF
L15| F7| Push-to-toggle all protection ON/OFF| All protection is OFF
L16| F8| Push-to-toggle instantaneous protection ON/OFF| Instantaneous protection is OFF
L17| F9| User-defined| User-defined
L18| F10| User-defined| User-defined
L19| F11| User-defined| User-defined
L20| F12| Push-to-trip and reclose recloser| —-
LED| Button| Description| If the associated LED is lit, the status:**
---|---|---|---
L9| F1| Push-to-open recloser| Recloser is OPEN
L10| F2| Push-to-close recloser| Recloser is CLOSED
L11| F3| Push-to-toggle reclose functionality ON/OFF| Reclose functionality is ON
L12| F4| Push-to-toggle hot line tag ON/OFF| Hot line tag is ON
L13| F5| Push-to-toggle ground fault protection ON/OFF| Ground fault protection is OFF
L14| F6| Push-to-toggle SEF protection ON/OFF| SEF protection is OFF
L15| F7| Push-to-toggle all protection ON/OFF| All protection is OFF
L16| F8| Push-to-toggle instantaneous protection ON/OFF| Instantaneous protection is OFF
L17| F9| User-defined| User-defined
L18| F10| User-defined| User-defined
L19| F11| User-defined| User-defined
L20| F12| Push-to-trip and reclose recloser| —-

Quick reference navigation tree guide for type 7SR relay

If LCD screen does not say “ENTER to CONTROL”, press the Cancel button until it does. This will not cause the recloser to operate.

Press enter.

SIEMENS 7SR224 Three Phase SDR Recloser-fig-5

Settings mode detailed tree

SIEMENS 7SR224 Three Phase SDR Recloser-fig-6

SIEMENS 7SR224 Three Phase SDR Recloser-fig-7