DORAN 3604AG Tire Pressure Monitoring System User Manual

June 9, 2024
DORAN

DORAN 3604AG Tire Pressure Monitoring System

Product Information

The Doran TPMS Sensor is a tire pressure monitoring system composed of an RF chip, battery, antenna, and RF matching network. It is designed to monitor tire pressure, temperature, and acceleration with data transmitted via center frequency 434.1MHz. The TPMS chip model is Infineon SP400-1101 with an operation pressure range of 0 psi ~ 116 psi and a working temperature of -40 ~ 125. The RF chip model is MAX1479ATE with a maximum RF signal strength of 10dBm. The battery information includes the manufacturer F0188-LF (Li/SOCl2) with a capacity of 400mAh, normal voltage of 3.6V, extreme voltage of 3.8V, and an estimated lifespan of 6 years. The sensor is designed to be mounted onto the valve stem and has a built-in filter for the OTR model that can work with tires that have liquid inside. It has an IP6K9K protection rating when screwed onto the valve stem and can withstand temperatures ranging from -40 ~ 125 for storage and -40 ~ 120 for operation. The vibration requirements follow ISO16750-3, 4.1.2.9 Test IX for commercial vehicles with unsprung masses. The codes for climatic loads are E.

Product Usage Instructions

  1. Program the sensor ID into the receiver according to the receiver’s instructions.
  2. Install the sensor onto the valve stem using the following steps:
  3. Remove the valve stem cap and core.
  4. Attach the sensor to the valve stem in place of the core.
  5. Tighten the sensor securely onto the valve stem with the provided wrench.
  6. Replace the valve stem cap.

Note: The sensor should be installed by a qualified technician. For more information, refer to the Doran TPMS Sensor User Manual.

General Description

Tire pressure sensor is composed of RF chip, battery, antenna and Rf matching network. It is applied to monitor tire pressure, temperature and acceleration and the tire data is transmitted via center frequency 434.1MHz.

Operation Functions

Data Accuracy

  • (measure @0~70℃)
  • Temperature:+/-2℃
  • Pressure: +/-2psi

TPMS chip

  • Chip model#: Infineon SP400-1101
  • Working temperature: -40 ℃ ~ 125 ℃
  • Operation pressure range: 0 psi ~ 116 psi
  • Working Voltage: 2.3VDC ~ 3.6VDC

RF chip

  • Chip model: MAX1479ATE
  • Max. RF signal strength: 10dBm

Battery information

  • Manufacturer: F0188-LF (Li/SOCl2)
  • Capacity: 400mAh
  • Normal voltage: 3.6V
  • Extreme voltage:3.8V
  • Operation temperature: -55~125℃
  • Estimated life span: 6 years

Environmental requirement

The sensor will be mounted onto the valve stem. For the OTR model, it has the built-in filter which can work with the tire that has the liquid inside.

  • Temperature requirement: -40℃ ~ 125℃ for storage -40℃ ~ 120℃ for operation
  • Vibration: Refer to ISO16750-3, 4.1.2.9 Test IX — Commercial vehicle, unsprung masses
  • IP protection: IP6K9K (with sensor screwed onto valve stem)
  • Codes for Climatic loads: E

PMN: Doran TPMS Sensor for Agriculture Truck

Sensor Installation Instructions

Program the sensor ID into the receiver

To make TPMS products work properly, the sensor ID must be programmed into the receiver for each wheel to be monitored. The following operations are performed on the receiver.

  • Press the P button to enter the program mode. Select the wheel position and press S button to enter the sensor ID.
  • Input the last three digits of the sensor ID into the receiver by navigating the arrow keys.
  • Press the S button for three seconds to confirm the information. If there are more wheels to be programmed, repeat steps a-c in above until all the wheels have the sensor ID entered.
  • Finish the programming process by pressing the P button for 5 seconds to quit the program mode.

Install the sensor onto the valve stem

Once the receiver is prepared and programmed, simply screw the sensor onto the valve stem in each wheel. Be sure to inspect and replace any defective or cracked valve stems before installing the sensors. If replacements are necessary, suggest replacing the valve stems with a Brass or Stainless-Steel stem. It does improve the life of the stem due to premature failure from drying out and cracking. Inferior stems have been found in the market and can cause extensive damage. The sensor should he tightened only by hand not with a tool. Use a firm grip and tighten the sensor. When the sensor seal makes contact with the end of the valve stem only tighten the sensor an additional 1/2 turn. This should be tight enough to seal the sensor and hold it in place. Check for leaks with a soapy solution. The monitor or receiver will begin to receive and recognize the sensors, and it will display the wheel positions as they are received on the screen.

Manufacturer information

  • Company name: Doran Manufacturing LLC
  • Company address: 2851 Massachusetts Avenue Cincinnati, OH 45225 USA

FCC STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio / TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

RF exposure warning

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The equipment must not be co-located or operating in conjunction with any other antenna or transmitter.

Canadian Compliance Statement

This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device

Le present appareil est conforme aux CNR d’Industrie Canada applicable aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:

IMPORTANT NOTE

Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment.

Read User Manual Online (PDF format)