Please read this guide before using the product, and keep the guide for future reference. For detailed information about the device, please download the complete user manual from the official website (www.infirayoutdoor.com).

InfiRay-AFFO-AL25-Thermal-Imaging-Monocular-FIG-1

Package Contents

InfiRay-AFFO-AL25-Thermal-Imaging-Monocular-FIG-3

  • AFFO Series Thermal Imaging Monocular
  • Micro HDMI video output data cable
  • Type-C data cable
  • Power adapter
  • Neck strap
  • Drawstring bag
  • Lens cleaning cloth
  • Quick Start Guide

Components and Controls

  1. Eyeshade
  2. Diopter adjustment
  3. Down button
  4. Menu (M) button
  5. Up button
  6. Power button
  7. LED light
  8. Objective lens
  9. Lens cover
  10. USB rubber cap
  11. Power indicator
  12. Type C port
  13. Micro HDMI port

Getting Started

  • Open the lens cover (9).
  • Power on: Press and hold the Power (6) button for 2s to turn on the thermal imaging monocular.
  • When an infrared image is displayed in the eyepiece the device enters the working status.
  • Rotate the diopter adjustment knob (2) to adjust the resolution of the icon on the display. The diopter adjustment knob is used to adjust the eyepiece diopter for users with dliferent degrees of myopia.
  • Setting the image mode: briefly press the Up (5) button to set the image palette mode. There are five modes for selection: white hot ( ), black hot ( ), red hot ( ), pseudo color ( ), and target highlight ( ).
  • The icon on the top status bar is updated in real-time.
  • Setting the display brightness: In the main menu, select the display brightness option to set the display brightness level from level 1 to level 5.
  • Digital Zoom: On the home screen, briefly press the M (4) button to set the digital zoom.
  • Photography: On the home screen, short press the Down (3) button to take a photo.
  • Video Recording: On the home screen, press and hold the Down (3) button to start the video recording function.
  • Power off: After using the device, press and hold the
  • Power (6) button for 3 seconds to enter the power-off interface with a shutdown countdown. when the countdown icon turns to 0, release the button. After the current status is saved, the display turns black and the device is powered off. During the saving of data, do not disconnect it from the power source, otherwise, the data cannot be saved.
  • Standby: On the home screen, press the Power (6) button briefly to standby the device. And press the Power (6) button again to wake up the device.

Main Menu Function

  • On the home screen, press and hold the M (4) button to enter the menu interface.
  • Briefly press the Up (5) / Down (3) buttons to switch among the main menu options.
  • Main menu navigation is cyclical: as soon as the last menu option of the first tab is reached, the first menu option of the second tab starts.
  • Adjust the current parameters or enter the submenu with a short press of the M (4) button.
  • The button operations on the submenus are the same as above, that is, switch among options with Up (51 / Down (3) button, and press the M (4) button to confirm option and return to the upper menu.
  • In all menu interfaces, short press the Power (6) button return to the upper menu interface.
  • Automatic exiting from the main menu to the home screen will occur after 15 seconds of inactivity.

Button Operation

InfiRay-AFFO-AL25-Thermal-Imaging-Monocular-FIG-10

Charging

The AFFO series is supplied with a built-in rechargeable Li-ion battery pack, which allows operation up to 9.5 hours. When using the device for the first time, please fully charge it first.

  • Open the USB rubber cap (10) on the bottom of the device.
  • Connect the Type C plug of the data cable to the Type C port (12) on the device.
  • Connect another port of the data cable to the power adapter.
  • Insert the plug of the adapter into the 110-240V socket.
  • When the device is charging, the power indicator (11) next to the Type C port (12) is red. The power indicator (11) is on only in the charging status. When the power indicator (11) turns green, the device is fully charged.
  • When the power indicator (11) blinks alternately red and green, it indicates that the battery is not charged or the temperature is too high or too low.
  • When charging, a lighting icon will appear inside the battery icon on the display. The lighting icon will not disappear until the data cable is removed or the power is cut off.
  • Charging is finished when the interior of the battery icon on the display is completely green .
  • During using, when the battery icon turns red , this means the power level is low, please charge the device in time to avoid data loss.

Specifications

InfiRay-AFFO-AL25-Thermal-Imaging-Monocular-FIG-15 InfiRay-AFFO-AL25-Thermal-Imaging-Monocular-
FIG-16

  • Actual operation time depends on the intensity of Wi-Fi use and the built-in video recorder.
  • Improvements may be made to the design and software of this product to enhance its useful features.
  • Technical parameters of the device may be improved without prior notice of the customer.

Update and InfiRay Outdoor

In order to continuously improve the product performance and provide a better user experience, the software program, as well as parameters and operating instruction of the device Will be constantly updated. Users can go to the official website (www.lnflrayoutdoor.com) to download and update. The AFFO series thermal imaging monocular support APP technology, and can be connected to a smart phone or tablet PC via Wi-Fi for real-time image transmission, control operations, and program updates.

You can download and install the lnfiRay Outdoor APP on the official website (www.infirayoutdoor.com) or APP store. Alternatively, you can download the APP by scanning the following QR code.

Important Safety Information

Environmental influences

  • Never point the lens of the device directly at intense heat sources such as the sun or laser equipment. The objective lens and eyepiece can function as a burning glass and damage the interior components.
  • Avoid touching the metal surface (cooling fins) after exposure to sunlight or cold.

Ergonomics notes

  • Take breaks after longer periods of use to avoid wrist pain.

Risk of swallowing

  • Do not place this device in the hands of small children.
  • Incorrect handling can cause small parts to come loose which may be swallowed.

Safety Instructions for use

  • Handle the device with care: rough handling can damage the internal battery.
  • Do not expose the device to fire or high temperatures.
  • Do not disassemble the device to access the battery. The battery is not meant to be replaced by the end user.
  • Only charge the device at temperatures ranging between 0 . c and 40″C.

User information on the disposal of electrical and electronic devices (private households) 2012/19/EU (WEEE directive)

Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.

For more information see: www.recyclethis.info.

Intended use

The device is intended for displaying heat signatures during nature observation, remote hunting observations and civil use. This device is not a toy for children. Use the device only as described in this operating manual. The manufacturer and the dealer accept no liability for damages that arise due to non-intended or incorrect use.

Function test

  • Before use, please ensure that your thermal imaging monocular has no visible damage.
  • Test to see if the thermal imaging monocular displays a clear, undisturbed image.
  • Check that the settings for the thermal imaging monocular are correct.

Legal and Regulatory Information

Wireless transmitter module frequency range:

  • WLAN: 2.412-2.472GH2 (For EU)
  • Wireless transmitter module power<20dBm (only for EU)

IRay Technology Co., Ltd. thus declares that the AFFO series thermal imaging monocular complies with the directives 2014/53/EU and 2011/65/EU. The full text of the EU declaration of conformity as well as additional information are available at: www.infirayoutdoor.com.

This device may be operated in all member states of the EU.

Regulatory information USA

_ FCC ID: _2AYGT-AFFO

FCC STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

information to the user

  • Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.

Body-worn Operation

This device was tested for typical body-support operations. To comply with RF exposure requirements, a minimum separation distance of 0.5cm must be maintained between the user’s body and the handset, including the antenna. Third-party belt clips, holsters, and similar accessories used by this device should not contain any metallic components. Body accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or approved antenna.

We, IRay Technology Co., Ltd., hereby declare that this product was tested conforming to the applicable FCC rules under the most accurate measurement standards possible and that all the necessary steps have been taken and are in force to assure that production units of the same equipment will continue to comply with the Commission’s requirements.

IRay Technology Co., Ltd.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)