HY-BRID LIFTS ZT-1230 Emergency Lowering System Instructions

June 9, 2024
HY-BRID LIFTS

HY-BRID LIFTS ZT-1230 Emergency Lowering System Instructions

Auxiliary Lowering: Descent – Manual Override
For manually lowering the scissors in the case of power failure, a manual valve on the pump is provided. To lower the scissors, pull the cable located near the rear or the machine.


FIGURE 1: Auxiliary Lowering


FIGURE 2: Lowering Instructions

WARNING
IF PLATFORM SHOULD FAIL TO LOWER, DO NOT ATTEMPT TO CLIMB DOWN THE SCISSOR ASSEMBLY. SERIOUS INJURY MAY RESULT. HAVE AN EXPERIENCED OPERATOR USE THE EMERGENCY LOWERING PROCEDURE TO SAFELY LOWER THE PLATFORM.

WARNING
BEFORE LOWERING PLATFORM, RETRACT THE DECK EXTENSION.

Emergency Stop
This lift is equipped with two emergency stops, one at the platform control and one at the base control, that when activated, will render the unit inoperable until reset. To reset, pull the emergency stop out.

WARNING
PUSHING THE EMERGENCY STOP WILL APPLY BRAKES IMMEDIATELY. THIS MAY CAUSE UNEXPECTED PLATFORM MOVEMENT AS THE MACHINE COMES TO A SUDDEN STOP. BRACE YOURSELF AND SECURE OBJECTS ON THE PLATFORM DURING OPERATION OF THE MACHINE.