Product Description

The JT-RAD01 is a radiation meter for the detection of alpha, beta, and X-ray radiation. It is designed for easy handling with high measurement stability and a sturdy design. The product features a large LCD color display with backlight, and measurement results can be displayed as both clear statistics and graph evaluations.

Product Specifications

  • Detectable types of radiation: alpha, beta, and X-ray radiation
  • Measurement method: dose rate and cumulative radiation dose
  • Energy range sensitivity:
  • Battery:
  • Available languages:
  • Measurement units: mR/h, CPS, CPM, Microsievert per hour, Microgray per hour, and Milliroentgen per hour

Overview

  • LEFT/BACK button: Switch between view modes, hold to exit menu
  • DOWN button: Switch options down
  • UP button: Switch options up
  • RIGHT/SETTINGS button: Switch between view modes, hold to enter settings
  • OK/POWER button: Confirm, hold to turn device on/off

View Modes

The JT-RAD01 has two display modes that can be switched between using the Left or Right button:

  • Real-time view: Displays current radiation exposure, average radiation exposure per hour, highest measured radiation exposure, cumulative accumulated radiation exposure, and alarm trigger values for current and cumulative radiation exposure.
  • Graph view: Displays the course of radiation exposure as a graph with current radiation exposure, minimum and maximum measured radiation exposure.

Settings

To enter the settings, hold the right/SETTINGS button. Navigate the settings menu using the up and down buttons. Press the right button to enter a sub-menu and the left button to exit. Available settings include:

  • Units: Set the measurement unit used for the current radiation level, minimum radiation level, and maximum radiation level. Available units include mR/h, CPS, CPM, microsievert per hour, microgray per hour, and milliroentgen per hour.

Safety Instructions

It is important to follow safety precautions while using the JT-RAD01:

  • Read the user manual carefully before use.
  • Handle the device with care to avoid damage and malfunctions.
  • Do not expose the device to extreme temperatures or humidity.
  • Do not use the device near electromagnetic fields or high-voltage sources.
  • Dispose of the device properly according to local regulations.

Support and Additional Information

If you have any questions or concerns about the product, please contact our customer support team. Additional information about the product can be found in the user manual.

Product Usage Instructions

To use the JT-RAD01:

  • Turn on the device by holding down the OK/POWER button.
  • Select real-time view or graph view using the Left or Right button.
  • View radiation exposure statistics or graphs on the LCD display.
  • Hold the right/SETTINGS button to enter the settings menu and navigate using the up and down buttons.
  • Press the right button to enter a sub-menu and the left button to exit.
  • Adjust measurement units as desired.
  • Follow safety instructions while using the device.

NUCLEAR RADIATION DETECTOR
JT-RAD01

PRODUCT DESCRIPTION

The JT-RAD01 is a radiation meter for the detection of ɣ-, ꞵ- and X-ray radiation and is characterized by its particularly easy handling, high measurement stability and its handy and robust design. The meter has a large LCD color display with backlight. The measurement results can be displayed both as clear statistics and as a graph evaluation.

PRODUCT SPECIFICATIONS

  • DETECTABLE TYPES OF RADIATION ɣ rays, ꞵ rays, x rays
  • MEASUREMENT METHOD Geiger Miller Counter
  • DOSIS RATE 0.00 – 1000 μSv/h (10 mSv/h)
  • CUMULATIVE RADIATION DOSE 0.00 μSv – 500.0 mSv
  • ENERGY RANGE 48 keV – 1.5 MeV ≤± 30% (CS-137)
  • SENSITIVITY 80 CPM/μSv (Co-60)
  • BATTERY 1100 mAh Lithium-Ion-Battery
  • AVAILABLE LANGUAGES English, German
  • DOSIS UNITS μSv/h, μGy/h, mR/h, cps, cpm

OVERVIEW

VIEW MODES

The JT-RAD01 has two display modes that can be switched between. Press the Left or Right button to switch between the modes:

REAL TIME VIEW
All relevant data is displayed in the real-time view. This includes the current radiation exposure, the average radiation exposure per hour, the highest measured radiation exposure, the cumulative accumulated radiation exposure, and the alarm trigger values for the current and cumulative radiation exposure.

GRAPH VIEW
In the graph view, the course of the radiation expo-sure is displayed in the form of a graph. In addition, the current radiation exposure as well as the minimum and maximum measured radiation expo-sure are displayed.

SETTINGS

To enter the settings, press and hold the right/settings button. You can navigate through the settings menu with the up and down buttons. Press the right button to enter a sub-menu. To leave the sub-menu, press the left button.

UNITS
Set the measurement unit used for the current radia-tion level, the minimum radiation level and the maxi-mum radiation level. You can choose between the following units:

  • μSv/h Microsievert per hour
  • μGy/h Microgray per hour
  • mR/h  Milliroentgen per hour
  • CPS Counts per second
  • CPM Counts per minute

LIMITS
Here you can set the limits individually. The alarm limit of the current radiation exposure as well as the alarm limit of the cumulative exposure and the reset value of the cumulative exposure can be defined here.

CLOCK
Set the current date and time here.

ALARM
Define here the ways you want to be informed about increased radiation exposure. You can choose from the following options:

  • LED A red LED above the display indicates the counts by the current radiation exposure.
  • VIBRATION A vibration alerts you when the set alarm limit is exceeded.
  • SOUND A sound alerts you when the set alarm limit is exceeded.

DISPLAY
Both the display brightness and the system language can be set here. The languages English and German are available.

SAFETY INSTRUCTIONS

  • Please note that our device is not a medical device or protective equipment, no health decisions should be made based on the readings from this device. We recommend always making decisions with your health in mind. Avoid dangerous situations and play it safe.
  • The device is expressly not intended to be used to assess whether there is a danger from radiation or to determine how long to stay in the contaminated area, it provides a “rough” indication that is not suitable for assessing health risks. Only professional equipment specifically designed for such purposes should be used.
  • Do not open the device, components inside work with high voltage, there is a risk of serious injury up to death by electric shock. Maintenance and repair may only be carried out by the manufacturer or an electrician who has been trained in the product!
  • Protect the product from extreme temperatures, mechanical stress, strong vibrations as well as flammable gases, vapors and solvents. Use the device only in a dry environment, it must not get wet or damp.
  • The device heats up when charging, do not cover it, it should not be charged unattended. Please use a 5 V 500 mA charger.
  • Always handle the product with care. Shocks, jolts and falls, even from a low height can damage the device. The counting tube inside is made of glass and is fragile.
  • If safe operation is no longer possible, take the product out of operation immediate-ly. Safe operation is no longer guaranteed if the device shows visible damage, no longer functions properly, has been stored under unfavorable conditions for a longer period of time or has been subjected to a considerable transport load. In this case, please contact the manufacturer for further instructions.
  • Your device is equipped with a lithium-ion battery 1100 mah, lithium-ion batteries are safe if handled properly, but if the device / battery is damaged or gets wet, there is a risk of heat development, up to fire. In case of damage where it can not be excluded that the internal battery was damaged, we recommend storing in a fireproof container in a safe place, this should not be your home!

SUPPORT

We also support you after your purchase. If you have any questions left or encounter any problems, please do not hesitate to contact us:
E-Mail: service@joy-it.net
Ticket-System: https://support.joy-it.net
Phone: +49 (0) 2845 – 9360 – 50 (10 – 17 oʼclock)
Please visit our website for more information: www.joy-it.net

ADDITIONAL INFORMATION

Our information and take-back obligations according to the Electrical and Electronic Equipment Act (ElektroG)
SYMBOL ON ELECTRICAL AND ELECTRONIC EQUIPMENT:

This crossed-out dustbin means that electrical and electronic appliances do not belong in the household waste. You must return the old appliances to a collection point. Before handing over waste batteries and accumulators that are not enclosed by waste equipment must be separated from it.

RETURN OPTIONS:
As an end user, you can return your old device (which essentially fulfills the same function as the new device purchased from us) free of charge for disposal when you purchase a new device. Small appliances with no external dimensions greater than 25 cm can be disposed of in normal household quantities independently of the purchase of a new appliance.
POSSIBILITY OF RETURN AT OUR COMPANY LOCATION DURING OPENING HOURS:
SIMAC Electronics GmbH, Pascalstr. 8, D-47506 Neukirchen-Vluyn, Germany
POSSIBILITY OF RETURN IN YOUR AREA:
We will send you a parcel stamp with which you can return the device to us free of charge. Please contact us by email at Service@joy- it.net or by telephone.
INFORMATION ON PACKAGING:
If you do not have suitable packaging material or do not wish to use your own, please contact us and we will send you suitable packaging.

FOR MAKERS AND PROFESSIONALS
WWW.JOY-IT.NET
JT-RAD01

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals