Govee H7142 Smart Humidifier User Manual
- June 4, 2024
- Govee
Table of Contents
- Safety Instructions
- Power Cord & Plug
- Package Includes
- Specifications
- Getting to Know Your Smart Humidifier
- Operate the Humidifier
- Memory Function
- Getting Started
- Using Your Smart Humidifier
- Care & Maintenance
- Descaling the Humidifier
- Cleaning the Aroma Pad
- Storing
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Model: H7142 User Manual
Govee Smart Humidifier
READ AND SAVE THESE INSTRUCTIONS
Safety Instructions
General Safety
- Only use the humidifier as described in this manual.
- When not in use for an extended period, turn the humidifier off and disconnect the plug from the outlet. Do not use the humidifier in wet environments.
- Keep the humidifier out of reach from children.
- Do not attempt to disassemble the humidifier or its components.
- Always unplug the humidifier from power before cleaning it or detaching the water tank from the
- humidifier base. Always place the humidifier on a flat, horizontal surface before using it.
- Only fill the water tank with clean water. Never fill the water tank with any other liquids.
- Do not place the humidifier near heat sources such as stovetops, ovens, or radiators.
- Do not place the humidifier directly on carpets or rugs.
- Do not use non-Govee humidifier parts as replacement parts for this product.
- Do not cover the nozzle while the humidifier is on, as this may damage the humidifier.
- Remove the water tank from the base before moving the humidifier.
- Do not immerse the humidifier base, power cord, or power plug in water.
- If the humidifier is damaged or is not functioning properly, stop using it and contact
- Customer Support immediately. Not for commercial use. Household use only.
- To reduce the risk of fire, electric shock, or another injury, always follow all instructions and safety
- guidelines.
Power Cord & Plug
- Ensure that the plug fits properly into a polarized outlet.
- Do not handle the power cord or plug with wet hands. Keep the power cord and plug away from liquids. Your humidifier has a polarized plug (one prong is wider than the other), which fits into a polarized outlet
- in only one orientation. This is a safety feature to reduce the risk of electric shock. If the plug does not fit, reverse the plug to the correct orientation. If it still does not fit, do not bypass this safety feature and try forcing the plug into the outlet; instead, do not use it with the outlet.
Risk of Leaks and Electric Shock
- Do not add essential oils, supplemental water treatment liquids, or water filters into the water tank or base chamber, as this may damage the humidifier and cause leaks.
- Only add essential oils to the aroma pad.
Package Includes
Item | Quantity |
---|---|
Smart Humidifier | 1 |
Cleaning Brush | 1 |
Aroma Pads (1 Pre-Installed) | 3 |
Quick Start Guide | 1 |
User Manual | 1 |
Specifications
Power Supply | AC 120V, 60Hz |
---|---|
Rated Power | 26W |
Water Tank Capacity | 1.5gal/6L |
Max Run Time (low mist setting) | 60 HoursNote: The humidifier may run for |
a longer or shorter time depending on the environmental temperature and
humidity.
Noise Level| ≤30dB
Effective Range| ≤602ft²/56㎡
Dimensions| 7.28X7.28X18.27 inch/ 18.5X18.5X46.4cm
Weight| 5.07lb/2.3kg
Getting to Know Your Smart Humidifier
a. Mist Nozzle
b. Water Tank Cover
c. Handle
d. Mist Tube
e. Max Water Line
f. Water Tank
g. Water Outlet Valve.
h. Cleaning Brush
i. UVC Light
j. Float
k. Bafie| l. Air Outlet
m. Transducer
n. Aroma Box
o. Aroma Pad
p. Power Cord
q. Air Inlet
r. Non-slip Pad
s. Night Light
---|---
Operate the Humidifier
Besides the on-device buttons, Govee Home App can also be used to control the below functions (as well as other app functions).
1. Controls
Power Button
Press to power on the humidifier.
Note: When the humidifier is powered off, its fan will continue spinning
for 15 seconds to clear away internal mist to avoid water vapor accumulation
that may afiect the life of the humidifier.
Mist Level Button
Press repeatedly to cycle through mist settings: Auto Mode, Mist Level 1, Mist
Level 2, Mist Level 3.
Note: The default target ambient humidity of Auto Mode is 60% when the
humidifier is not connected to Gove Home App.
You can set the target humidity for Auto Mode via Govee Home App.
The Custom Mode can only be set and activated via Govee Home App and not
directly on the humidifier.
Night Light Button
Press to turn on the night light.
Note: The brightness and color of the night light can be adjusted via
Govee Home App.
Timer Button
Press repeatedly to select a timer for the humidifier.
2. Display & LED Indicators
On-Device Display
Button| Display| Status
Mist Level Button| AU| Auto Mode
01| Mist Level 1
02| Mist Level 2
03| Mist Level 3
Timer Button| 01-24| Length of Timer Setting
| Humidity Level| Current Humidity
Wi-Fi Indicator / Color / Status
Wi-Fi Indicator| Slowly Flashes Blue| Ready to Connect
Quickly Flashes Blue| Wi-Fi Connecting
Solid Blue| Wi-Fi Connected
Button Indicator Status
Button Indicator| Color| Status
Power Button Indicator| Solid White| Power On
Dim| Power Off
Solid Red| Water Shortage
Flashes Red| The water Tank is not Positioned Correctly
Memory Function
The humidifier will remember its previous mist level, night light color/brightness, and Wi-Fi connection settings when powered off. These settings will become active again when the humidifier is turned back on.
Getting Started
- Remove all packaging and protective foams.
- Place the humidifier on a hard, flat, water-resistant surface. The humidifier should be least 12 inches/30 cm away from any walls.
- The mist should be directed away from walls, furniture, bedding, and appliances.
Filling with Water
- Remove the water tank cover using the small tab and add water directly into the tank. The tank can also be lifted off the base using the interior tank handle.
Note:
- Fill the tank with room-temperature water. Do not fill with hot water.
- It is recommended to fill the tank with purified or distilled water.
- Do not fill past the tank’s max water line.
- Do not add water or essential oils directly into the base chamber.
- Do not add water or essential oils into the mist tube.
- Do not add essential oils directly into the humidifier. Only add essential oils to the aroma pad.
- Do not use water treatment liquids or third-party water filters with this humidifier.
2. Reattach the water tank cover and place the tank back on the base.
Using Your Smart Humidifier
Note: Besides the on-device buttons, Govee Home App can also be used to
control the below functions (as well as other app functions).
Functions & Controls
Plug in your humidifier and press the Power Button to turn it on. Press the
Mist Level Button repeatedly to cycle through Auto Mode and the three mist
levels.
-
Auto Mode: The humidifier will automatically adjust the mist level according to the ambient humidity target set in-app, or 60% humidity when not connected to the app.
-
Custom Mode: You can customize this setting (running time & mist level) via the app. You can create up to 3 custom presets in the app.
-
9 Levels of Mist Adjustment: You can access up to 9 levels of mist via the Govee Home App for even finer control of mist release.
-
UVC Light: Turn on the interior UVC light via Govee Home App to kill most bacteria and mold in the base, making for a cleaner mist.
-
Night Light: Adjust the color and brightness of the integrated night light via the app.
-
360° Double Mist Nozzle: Adjust the mist direction by rotating the two mist nozzles.
-
Humidity Monitor: You can check the current environmental humidity via the on-device display or in Govee Home App.
-
Timers: You can set a 1-to-24-hour timer via the Timer Button or Govee Home App.
-
Scheduling: You can create up to 10 all-day schedules (power on/off & mist levels) via Govee Home App.
-
Third-party Voice Assistants: You can control this humidifier via third-party voice control assistants such as Alexa and Google Assistant.
Note:
When the tank is detached from the base: The humidifier’s fan will stop within
5 seconds and mist will stop being produced. If the tank is properly placed
back onto the base within 3 minutes, the humidifier will continue working; if
not, the humidifier will automatically turn off. No water left in the tank:
The humidifier will stop producing mist when there is not enough water in the
tank. The indicator light will show solid red and the fan will stop working
within 5 seconds. Once sufficient water is added back into the tank, the
humidifier will restart after pressing the Power Button.
Pairing Your Smart Humidifier with Govee Home App
Due to ongoing updates and improvements, Govee Home App’s interface and
features may be slightly different than those shown in the manual. In case of
differences, follow the in-app instructions.
- To download Govee Home App, scan the QR code or search for “GOVEE” in the Apple App Store (iOS) or Google Play Store (Android)
https://www.govee.com/apps/qrcode
Note: For Android users, choose to “Allow” permissions to use Govee Home
App.
- Turn on your smartphone’s Bluetooth.
- Open Govee Home App, tap the “+” icon in the top right corner, and search for “H7142 .”
- Tap the device icon and follow the on-screen instructions to complete the pairing.
Note: You can use Govee Home App to connect your smart humidifier to Amazon Alexa or Google Assistant. Follow the in-app instructions to connect Govee Home App to each voice assistant.
Using the Aroma Box
- Press to pop out the aroma box from the back of the base.
- Drip 8 to 10 drops of essential oil on the aroma pad.
- Push the aroma box back into the humidifier.
- Turn on the humidifier. The humidifier will automatically diffuse the aroma when used.
Note: Do not add essential oils, water treatment liquids, or third-party
water filters directly into the water tank or base chamber. Only add essential
oils to the aroma pad.
The aroma pads can be cleaned and reused after difiusing essential oils.
The aroma effect is intended to be light. This humidifier is not a dedicated
aroma diffuser.
Care & Maintenance
Cleaning the Humidifier
The humidifier should be cleaned after being used for a week or before being
stored.
Cleaning Steps
- Unplug the humidifier.
- Remove and rinse the water tank cover.
- Remove the water tank from the base and pour out any water from the tank and base chamber.
- Rinse the tank and base chamber with room temperature water.
Note: Keep the air inlet and outlet dry when cleaning the base with
running water. Internal components may be damaged if water enters the air
inlet or outlet.
If water does accidentally enter the base’s inlet or outlet, place the
humidifier base in a ventilated place to dry before using.
Descaling the Humidifier
-
Fill the tank with 3 cups/710 mL of distilled white vinegar.
-
Put the tank cover on and swish the vinegar around the tank.
-
Place the tank on the base and soak for 15–20 minutes. Vinegar will drain into the base chamber and loosen the scale (mineral buildup) in the tank and in the base chamber.
-
Remove the tank, remove the tank cover, and pour out all vinegar.
-
Remove the base and lift up the float. Use the cleaning brush to clean. Note:
Put the floating bafle back in place after removing it. -
Use a soft cloth and the included cleaning brush to remove limescale from all parts.
-
Rinse all parts until the vinegar smell is completely gone.
-
Dry all parts with a cloth. Make sure all parts are completely dry before reassembling or storing the humidifier.
Cleaning the Aroma Pad
-
Press and pop out the aroma box from the back of the base.
-
Remove the pad and rinse it under warm running water.
-
Dry the pad with a clean cloth and place it back into the aroma box.
Note: Do not pour liquid cleaners or detergents into the aroma pad or box.
Storing
Follow the cleaning instructions and allow all parts to dry completely before storing the humidifier in a cool, dry place.
Troubleshooting
Problem | Possible Solution |
---|---|
Humidity er doesn’t turn on or it powers o frequently. | Make sure the power |
cable is securely connected and press the Power Button again.
Check to see if the humidifier is in Auto Mode. If so, the humidifier may
automatically turn off when the humidity level is above the target level.
Little or no mist comes out.| Add at least 1L puried or distilled water to
the water tank.
Turn the mist level to a higher setting.
There may be too much water in the base chamber. Empty the base chamber and
rell the water tank (not the base chamber) and place the water tank properly
onto the base.
Make sure the air inlet on the bottom of the base is not blocked. The
humidier should not be set on carpet or other surfaces that may block the air
inlet.
Make sure the nozzle is not blocked or clogged.
Make sure the humidier is on a level surface.
The water temperature may be too low. Turn the mist level to the highest
setting and let the humidier run for a while, then adjust to the desired
setting.
The water temperature may be too low. Use room temperature water.
If the water tank or base was washed with detergent, it should be rinsed
thoroughly with clean water to remove residual detergent.
Humidifier uses water too fast.| The humidier uses up water based on the
environmental temperature and humidity. If the environment is cold and/or dry,
the humidier will run out of water faster.
Humidifier produces an unusual smell.| If the humidier is new, unplug and
rinse all parts, then place it
in a cool and dry place for 12 hours.
If essential oils were placed on the aroma pad, the pad should be rinsed with
clean water and left to dry.
Clean the water tank and base chamber.
Humidity er makes a loud or
unusual noise.| Set the mist level to a lower setting.
The humidier may be malfunctioning. Stop using it and contact Give Customer
Support.
White dust appears around the humidier.| We recommend using puried or
distilled water to ll the humidier. Avoid using water with high mineral
content.
Clean the water tank and base chamber.
Make sure the silicone sealing ring around the water outlet valve is secure.
Water leaks from the humidier.| Avoid running the humidier in a room with
over 60% relative humidity.
Do not shake the humidier.
Make sure to place the humidier on an at, level surface.
Check the water tank for leaks. If there are leaks, contact Gove Customer
Support.
Condensation forms around humidier or windows.| Humidity may be too high.
Turn down the mist level, turn o‑ the humidier, or open a door or window to
the room.
Mold grows inside the humidier.| Clean the water tank and base chamber
regularly.
The essential oil has little or no smell.| Add more essential oil. For best
results, use pure essential oil.
The power indicator light shows solid red.| The tank is short of water. Please
rell the tank.
Power indicator fiashes red.| The water tank is not properly positioned.
Please place the water tank correctly on the base.
The humidity showed on the display or in the app is not accurate.| The space
the humidifier is being used in may be larger than that intended for this
product. Please use the humidifier in a space less than 602ft²/56㎡.
The humidity sensor at the bottom of the humidifier may be damp. Please turn
off the humidifier and dry the base.
The night light cannot be turned on or adjusted via the app.| Check whether
the app is connected to the humidifier.
If the night light still cannot be operated when the app and the humidifier
are connected, please contact Govee Customer Support.
For App & Connectivity
-
Cannot connect to Gove Home App.
Make sure the Bluetooth of your smartphone is enabled and your smartphone is not connected with other Bluetooth Humidifiers.
Enable the smartphone’s Location Services.
Try connecting with another smartphone.
Make sure your app is updated to the latest version.
Make sure you have connected to the 2.4GHz network, and confirm the network is working correctly.
Make sure the Wi-Fi password you entered is correct.
Shorten the distance between the humidifier, Wi-Fi router, and smartphone.
Make sure your humidifier and the Wi-Fi router are not placed near. appliances that produce electromagnetic radiation (e.g. microwave ovens, refrigerators, etc.).
If you are using a VPN, try turning it off and then connecting the humidifier. Disable portal authentication for your Wi-Fi network. If portal authentication is enabled, this humidifier will not be able to access your Wi-Fi network, and setup will fail. Portal authentication means that you need to sign in to your Wi-Fi network through a web page before you can use the Internet. -
Cannot find the humidifier within in nearby Bluetooth humidifiers list.
The humidifier may be connected to another smartphone. Disconnect it from the other smartphone first. -
The humidifier is ofiine.
Make sure the humidifier is plugged in and powered on, then refresh “My Humidifiers” in Govee Home App by swiping down on the screen.
Make sure your router is connected to the internet, and your phone’s network connection is working.
If the Wi-Fi password has changed, the humidifier will automatically go online. Try connecting it to the network again.
Delete the office humidifier from Govee Home App, then add and reconfigure the humidifier again in the app.
FCC Statement
This device complies with Parts 15 & 18 of the FCC Rules. Operation is subject
to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Parts 15 &18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver.
(3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
(4) Consult the dealer or an experienced radio/TV technician for help.
FCC Radio Frequency Exposure Statement
The device has been evaluated to meet general RF exposure requirements. The
device can be used in fixed/mobile exposure conditions. The min separation
distance is 20cm.
FCC ID:2AQA6-H7142
The following importer is the responsible party
Responsible party : Name: GOVEE MOMENTS(US) TRADING LIMITED
Address: 13013 WESTERN AVE STE 5 BLUE ISLAND IL 60406-2448
Email: support@govee.com
Contact information: https://www.govee.com/support
IC Statment
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.”
The Bluetooth ® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Shenzhen Intellirocks Tech. Co., Ltd. is under license.
Customer Service
Warranty: 12-Month Limited Warranty
Support: Lifetime Technical Support
Email: support@govee.com
Official Website: www.govee.com
| @Govee
---|---
| @goveeocial
| @govee.oficial
| @GoveeOficial
| @GoveeOficial
https://www.govee.com/apps/qrcode
For FAQs and more information,
please visit: www.govee.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>