diplomat EDL77 Advance Digital Lock Instructions

June 9, 2024
diplomat

diplomat EDL77 Advance Digital Lock

OVERVIEW

diplomat-EDL77-Advance-Digital-Lock-FIG-1

How to open?

  • Step 1. Press ” C ” button
  • Step 2. Press factory code ” 1 2 3 4 “
  • Step 3. Press ” # ” button
  • Step 4. Turn knob (Key or Handle) clockwise and open the door while melody rings.diplomat-EDL77-Advance-Digital-Lock-FIG-2

How to close?

  1. Home Safe(EN, EK) : Close the door, and turn the knob(or key) counter-clockwise.
  2. Office Safe(EH) : Close the door. Then it is locked automatically.
  3. Office Safe(EHK) : Close the door, and turn the key counter-clockwise by 360′ to take it out.
    • In the case of EHK, if you want to use a digital lock only, please turn the metal key clockwise by 360° and take it out.

How to enter 1st code?

  • Step 1. Press the ” M ” button
  • Step 2. Press the New Code buttons (4 digits min to 16 digits max)
  • Step 3. Press the ” # ” button (Melodic tone)
  • EX) If a new code is decided 2 1 O O, press the buttons as below. M 2 1 O O # ( Melodic tone)

To confirm if the code is exactly entered, press the code in opening procedures prior to closing door. For example, in case of your code 4 4 0 0, press button C 4 4 O O #. If the procedure is properly done, melody rings for 3 seconds.

How to enter 2nd code?

  • Step 1. Press ” M ” button
  • Step 2. Press ” 2 ” button
  • Step 3. Press ” #” button
  • Step 4. Press 2nd New Code buttons (4 digits min to 16 digits max )
  • Step 5. Press ” #” button (Melodic tone)diplomat-EDL77-Advance-Digital-Lock-FIG-4

To confirm if the code is exactly entered, press the code in opening procedures prior to closing door. For example, in case of your code 4 4 0 0, press button C 4 4 0 0 #. If the procedure is properly done, melody rings for 3 seconds.

How to erase the 2nd code?

  • Step 1. Press ” M ” button
  • Step 2. Press ” # ” button
  • Step 3. Press ” 2 ” button
  • Step 4. Press ” # ” button (Melodic tone)

When to replace batteries?

  1. If you hear an abnormal ‘Bi-ric’ , not ‘Beep’ sound when you press any button.
  2. The door is not opened in spite of exact code entered.
  • Battery life span : 2 years (In case of three door openings a day) EDL77: 1. SV AA Alkaline 4pcs / REDL2: 1. SV AAA Alkaline 4pcs
  • Insulated containers are intended to release moisture to protect paper records during a fire. Therefore the door should be opened frequently to permit free circulation of air.
  • Stamps, coins, films, photographs, etc., must be placed in friction lid containers or heavy-duty (boil-proof) plastic bags and wrapped in aluminum foil lo prevent moisture damage.

To improve products constantly., Diplomat Safe reserves the right to alter the specitications without prior notice. Printed in Korea, June 8, 2012 REV, 6

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

diplomat User Manuals

Related Manuals