BROADCOM MegaRAID 9540-2M2 Boot Adapter User Guide
- June 9, 2024
- BROADCOM
Table of Contents
- BROADCOM MegaRAID 9540-2M2 Boot Adapter
- Documentation Legal Notice
- Broadcom MegaRAID 9540-2M2 Boot Adapter
- RAID Features
- Operating System Support
- PCIe Host Interface
- Storage Interface Features
- Adapter Security
- Adapter Installation Instructions
- MegaRAID 9540-2M2 Boot Adapter – Connector and LED Designations
- MegaRAID 9540-2M2 Boot Adapter Technical Specifications
- Marks, Certifications, Compliance, and Safety Characteristics
- Revision History
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BROADCOM MegaRAID 9540-2M2 Boot Adapter
Documentation Legal Notice
Copyright © 2022 Broadcom. All Rights Reserved. The term “Broadcom” refers to
Broadcom Inc. and/or its subsidiaries. For more information, go to
www.broadcom.com. All trademarks, trade names,
service marks, and logos referenced herein belong to their respective
companies.
Broadcom reserves the right to make changes without further notice to any
products or data herein to improve reliability, function, or design.
Information furnished by Broadcom is believed to be accurate and reliable.
However, Broadcom does not assume any liability arising out of the application
or use of this information, nor the application or use of any product or
circuit described herein, neither does it convey any license under its patent
rights nor the rights of others.
Broadcom MegaRAID 9540-2M2 Boot Adapter
This document is the primary reference and user guide for the Broadcom® MegaRAID™ 9540-2M2 boot storage adapter. The adapter supports two M.2 SSDs for high performance from an easy-to-install board designed to boot a server’s operating system. The M and B+M key solution allow SATA and PCIe (NVMe) compatibility, providing a boot adapter solution with reliability and various transfer rates. The adapter negotiates between the speeds and the protocols to recognize and concurrently interface with the two storage devices types. This document contains the complete installation instructions and specifications for the boot adapter.
RAID Features
The following list includes primary RAID features that the adapter supports. For a full description of the RAID features, refer to the 12Gb/s MegaRAID Tri- Mode Software User Guide, located at http://www.broadcom.com/support /download-search.
- RAID level 0 and 1
- Online Capacity Expansion (OCE)
- Auto resume after loss of system power during array rebuild or OCE
- Fast initialization for quick array setup
- Check Consistency for background data integrity
- SSD support with SSD Guard™ technology
- Patrol read for media scanning and repairing
- Disk data format (DDF)-compliant Configuration on Disk (COD)
- Self-Monitoring, Analysis, and Reporting Technology (S.M.A.R.T) support
- MegaRAID SafeStore™ Software for SafeStore disk encryption (SED) key management
Operating System Support
The tri-mode storage adapters support the operating systems in the following list. For specific version information, refer to the MegaRAID Tri-Mode Device Driver Installation User Guide, located at http://www.broadcom.com/support /download-search.
- Microsoft Windows
- VMware vSphere/ESXi
- Red Hat Enterprise Linux
- SuSE Linux
- Ubuntu Linux
- Citrix XenServer
- CentOS Linux
- Debian Linux
- Oracle Enterprise Linux
- Fedora
- FreeBSD
The firmware and drivers are routinely updated and made available on the Broadcom Support and Download center. Visit http://www.broadcom.com/support /download-search and download the latest firmware and driver for the adapter.
PCIe Host Interface
The adapter’s PCIe 4.0 host interface provides maximum transmission and reception rates of up to 128 GT/s (16GB/s per lane). The tri-mode controller uses a packet-based communication protocol to communicate over the serial interconnect. Other PCIe host interface features include the following:
- Eight-lane PCIe host interface
- PCIe Hot Plug
- Power management:
- Supports the PCI Bus Power Management Interface Specification Revision 1.2
- Supports Active State Power Management, including the L0 states, by placing links in a power-saving mode during times of no link activity
- Error handling
- High bandwidth per pin with low overhead and low latency
- Lane reversal and polarity inversion
- Single-phy (one-lane) link transfer rate of 16 GT/s, 8 GT/s, 5 GT/s, and 2.5 GT/s in each direction
- Eight-lane aggregate bandwidth of up to 16GB/s (16,000 MB/s)
- Support of x8, x4, x2, and x1 link widths
Storage Interface Features
The adapter’s SerDes technology enables maximum flexibility by supporting NVMe or SATA M.2 drives for operating system boot applications. The adapter detects the drive type and negotiates between speeds and protocols to automatically recognize and function with NVMe or SATA M.2 drives.
- PCIe (NVMe) interface features:
- x1, x2, or x4 NVMe drive support
- Data transfer at 16GT/s, 8GT/s, 5GT/s, and 2.5GT/s
- SATA interface features:
- SATA data transfer rates of 6Gb/s and 3Gb/s
Adapter Security
The adapter hardware secure boot security feature protects your system from
malicious activity.
Hardware secure boot permits only authenticated firmware to execute on the
adapter. The adapter boots from an internal boot ROM, which establishes the
initial root of trust (RoT). Hardware secure boot authenticates and builds a
chain of trust (CoT) with succeeding firmware images by using the RoT, meaning
only authorized firmware executes on the adapter.
Figure 1: Authenticated Firmware Example
Hardware secure boot requires that each image be signed with a valid digital signature; otherwise, the image is considered invalid and does not execute. The adapter ships with a valid signed firmware image. All Broadcom-supplied firmware includes a valid digital signature; therefore, the hardware secure boot process is transparent unless the adapter encounters a counterfeit image. If the adapter downloads a counterfeit image, the image authentication fails and the download utility, such as StorCLI2, displays the appropriate failure messages. Contact Broadcom Technical Support for assistance.
Adapter Installation Instructions
Use the following steps to install the adapter:
-
Unpack your adapter.
Unpack and remove the adapter. Inspect the adapter for damage. If it appears damaged, contact Broadcom Technical Support.
ATTENTION
To avoid the risk of data loss, back up your data before you change your system configuration. -
Turn off the power to the system.
Turn off the power to the computer and disconnect the AC power cord. Remove the computer cover. Refer to the system documentation for instructions. Before you install the adapter, make sure that the computer is disconnected from the power and from any networks.
CAUTION
Disconnect the computer from the power supply and from any networks to which you will install the adapter, or you risk damaging the system or experiencing electrical shock. -
Review the adapter connectors. See MegaRAID 9540-2M2 Boot Adapter – Connector and LED Designations for descriptions of the adapters that show their connectors.
-
Check the mounting bracket on the adapter.
If required for your system, replace the full-profile mounting bracket that ships on the adapter with the low-profile bracket supplied. Complete the following steps to attach the low-profile bracket:- Using a No. 1 Phillips screwdriver that is ESD safe, remove the two Phillips screws that connect the full-profile bracket to the board. Unscrew the two screws located at the top and bottom edges of the board. Avoid touching any board components with the screwdriver or the bracket.
- Remove the full-profile bracket. Do not damage the adapter.
- Place the adapter on top of the low-profile bracket. Position the bracket so that the screw holes in the tabs align with the openings in the board.
- Using a No. 1 Phillips torque screwdriver that is ESD safe, set to a maximum torque of 4.8 ± 0.5 inch-pounds. Replace the two Phillips screws removed in Step a.
ATTENTION
Exceeding this torque specification can damage the board, connectors, or screws, and can void the warranty on the board.
ATTENTION
Damage caused to the board as a result of changing the bracket can void the warranty on the board. Adapters returned without a bracket mounted on the board will be sent back without return merchandise authorization (RMA) processing.
-
Install the stand-offs. Two black plastic stand-offs with attached fasteners are provided with the adapter. Insert the stand-offs in the appropriate holes for the M.2 drive length and press to snap into place.
-
Install the M.2 drives. Install the M.2 SSDs into the adapter’s connectors. Secure the SSDs into place by pushing the fastener through the notch on the M.2 drive into the stand-off. The adapter supports the following M.2 drive lengths:
- 110 mm
- 80 mm
- 60 mm
- 42 mm
- 30 mm
-
Insert the adapter into an available PCIe slot. Select a PCIe slot and align the adapter’s PCIe bus connector to the slot, as shown in the following figure. Press down gently, but firmly, to make sure that the adapter is seated correctly in the slot. Secure the bracket to the computer chassis with the bracket screw.
NOTE
Adapters with a x8 host interface can operate in x8 or x16 slots. However, some x16 PCIe slots support only PCIe graphics cards; an adapter installed in one of these slots will not function. Refer to the guide for your motherboard for information about the PCIe slots.
Figure 2: Installing an Adapter in a PCIe Slot
-
Provide the required airflow for the installed adapter. See MegaRAID 9540-2M2 Boot Adapter Technical Specifications to find the adapter’s cooling requirements.
-
Turn on the power to the system. Reinstall the computer cover and reconnect the AC power cords. Turn on power to the host computer.
During boot, a BIOS message appears. The firmware takes several seconds to initialize. The configuration utility prompt times out after several seconds. The second portion of the BIOS message shows the adapter controller number, and firmware version. The numbering of the adapters follows the PCIe slot scanning order used by the host motherboard. -
Choose the correct storage profile. Refer to the 12Gb/s MegaRAID Tri-Mode Software User Guide and LSI® Storage Authority Software User Guide for details about setting up your adapter.
-
Install the operating system driver. The adapters can operate under various operating systems. To operate under these operating systems, you must install the software drivers. The firmware and drivers are routinely updated and made available on the Support and Download center. Visit http://www.broadcom.com/support/download-search and download the latest firmware and driver for the adapter.
MegaRAID 9540-2M2 Boot Adapter – Connector and LED Designations
The adapter is a 2.536 in. × 6.9 in. (64.41 mm × 175.26 mm) board. The
component height on the top and bottom of the adapter complies with the PCIe
Card Electromechanical specification.
The following figure shows the connectors and LED locations on the adapter. A
red circle near each header and connector identifies pin 1 in the figure.
Figure 3: Card Layout for the MegaRAID 9540-2M2 Boot Adapter
Table 1: Headers and Connectors
Connector | Type | Description |
---|---|---|
J2 | Standard edge card connector | The interface between the storage adapter |
and the host system.
With the PCIe interface, this connector provides power to the board and an I2C
interface connected to the I2C bus for the IPMI.
J4| Default SBR header| 2-pin connector. Reserved for Broadcom use.
J8| Onboard serial UART connector| 4-pin connector. Reserved for Broadcom use.
Connector| Type| Description
---|---|---
J10| Global HDD activity LED header| 2-pin connector.
Connects to an LED that indicates activity on the drives connected to the
controller.
J11| Global drive fault LED header| 2-pin connector.
Connects to an LED that indicates whether a drive is in a fault condition.
J114, J115| SSD connector| Two M.2 SSD connectors.
The following table describes the LEDs on the adapter.
Table 2: LED Designations
LED | Type | Description |
---|---|---|
LED2 | Yellow IOC over temperature | Stays on solid to indicate that the SAS3808 |
IOC temperature sensor is over the temperature threshold. When the IOC is in
the proper temperature range, this LED is off.
LED3| Green system heartbeat| Indicates that the SAS3808 IOC is operating
normally.
MegaRAID 9540-2M2 Boot Adapter Technical Specifications
The operating (thermal and atmospheric) conditions for the adapter are as follows:
- Relative humidity range (non-condensing): 5% to 90%
- Temperature range: 0°C to +55°C
The minimum airflow required depends on the installed M.2 SSDs. The minimal
airflow without any M.2 drives is 150 LFPM measured at 55°C (ambient). When
attaching M.2 drives, you must supply enough airflow to cool the M.2 drives
and to keep the SAS3808 IOC processor’s junction temperature at 105°C or less.
The M.2 drives might require heat sinks. M.2 drive heat sinks are available
from third-party suppliers.
The non-operating (such as storage and transit) conditions for the adapter are
as follows:
- Relative humidity range (non-condensing): 5% to 95%
- Temperature range: –40°C to +70°C
Power Supply Requirements
All power, included that used to power the onboard M.2 drives, is supplied
to the adapter through the PCIe 3.3V rail (3.3V± 9%) and the 12V rail (12V ±
8%). Onboard switching regulator circuitry operates from the 3.3V rail and the
12V rail to provide the necessary voltages. Each M.2 drive may use a maximum
of 11.55W.
The M.2 drives are powered from the 12V rail with the 1.5V and 1.8V SAS3808
supplies. Using the 12V rail, the adapter can support the maximum power
requirements of the M.2 drives. The SAS3808 core rail is powered from the 3.3V
rail which requires approximately 6W. This means, depending on the drives
being used, the adapter might draw more than 25W total (the limit of some x8
slots). However, many systems combine the 12V and 3.3V rails to supply up to
35W (25W from the 12V rail and 10W from the 3.3V rail). The total power
consumed depends on which M.2 SSDs drives are used. You must complete a power
analysis based on the drive selection for your system.
The following values represent typical power using two 500 GB x4 NVMe PCIe
16GT/s drives:
- PCIe 3.3V: 6W
- PCIe +12V: 11.5W
- Total power: 17.5W
Typical power is measured with maximum I/O traffic, typical silicon process material, and nominal voltages operating the card at an ambient temperature of 45°C with required airflow.
Marks, Certifications, Compliance, and Safety Characteristics
Marks, Certifications, and Compliance
The design and implementation of the boot adapter minimizes electromagnetic
emissions, susceptibility to radio frequency energy, and the effects of
electrostatic discharge. The MegaRAID 9540-2M2 boot adapter, model 50148,
shows the following marks and certifications.
Table 3: Adapter Marks and Certifications
Mark | Symbol | Description |
---|---|---|
Australia and New Zealand RCM | ** | |
** | Meets the following standards: |
- AS/NZS CISPR 32
- CISPR 32:2015, Class B
- AS/NZS CISPR 32:2015, Class B
Canada EMC| CANADA ICES-OO3 CLASS B CANADA NMB-003 CLASSE B CAN ICES-3 (B)/NMB-3 (B)| Meets the following standards:
- ICES-003:2016 Issue 6: 2016, Class B
- CAN/CSA CISPR 22-10
- CISPR 22:2008
Europe (CE)|
| Meets the following standards:
- EN 55022/EN 55024 EN 55032
- EN 55032:2015 +AC:2016, Class B
- EN 50022:2010 +AC:2011, Class B
- EN 55024:2010 +A1:2015
Korea (RRL)| ****| xxxxx = model number
Meets the KN32/KN35 testing requirements.
Taiwan (BSMI)| ****| Meets the following standards:
- CNS 13438
- CNS15663
Mark| Symbol| Description
USA /
Canada Safety (UL Listed)
| ****
| For use with UL listed ITE equipment only. Meets the following standards:
- UL 62368-1, Third Edition
- CAN/CSA C22.2 No. 62368-1-19, Third Edition
CB Scheme Safety| —| Meets the following standards:
- IEC 60950-1:2005 (Second edition) + Am 1:2009 + Am 2:2013
- EN 60950-1: 2006 + A11: 2009 + A1: 2010 + A12: 2011 + A2: 2013
- IEC 62368-1:2014 (Second edition)
- EN 62368-1:2014+A11: 2017
Japan (VCCI)| ****| Meets the following standards:
- V-3/2015.04, Class B
- V-4/2012.04
- VCCI-CISPR 32:2016
- CISPR 32:2015
USA /
Canada (FCC)
| ****| Meets the following standards:
- 47 CFR FCC Part 15, Subpart B, Class B
- ANSI C63.4:2014
- CISPR 32:2008
Morocco (CMIM)| ****| Meets the following standards:
- EN 55022/EN 55024 EN 55032
- EN 55032:2015 +AC:2016, Class B
- EN 50022:2010 +AC:2011, Class B
- EN 55024:2010 +A1:2015
Country of Origin| Made in XXXX| XXXX indicates the country of origin.
Safety Characteristics
The adapter meets or exceeds the requirements of UL flammability rating 94 V0.
Each bare board is also marked with the supplier name or trademark, type, and
UL flammability rating. For the boards installed in a PCIe bus slot, all
voltages are lower than the SELV 42.4V limit.
Revision History
Version 1.0, November 11, 2022 Initial document release.
9540-2M2-UG100
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>