BROADCOM LPE35002-M2 Emulex Fibre Channel Host Bus Adapters Installation Guide
- June 6, 2024
- BROADCOM
Table of Contents
Emulex® Fibre Channel Host Bus Adapters
Installation Guide Release 12.8
Broadcom, the pulse logo, Connecting everything, Avago Technologies, Avago,
the A logo, Emulex, and OneCommand are among the trademarks of Broadcom and/or
its affiliates in the United States, certain other countries, and/or the EU.
Copyright © 20032020 Broadcom. All Rights Reserved.
The term “Broadcom” refers to Broadcom Inc. and/or its subsidiaries. For more
information, please visit www.broadcom.com.
Broadcom reserves the right to make changes without further notice to any
products or data herein to improve reliability, function, or design.
Information furnished by Broadcom is believed to be accurate and reliable.
However, Broadcom does not assume any liability arising out of the application
or use of this information, nor the application or use of any product or
circuit described herein, neither does it convey any license under its patent
rights nor the rights of others.
Chapter 1: Introduction
This installation guide describes how to install an Emulex® FC HBA.
NOTE: Illustrations in this guide are examples only. The actual hardware
might vary.
Figure 1: Two-Port HBA
Figure 2: Single-Port
HBA
1.1 HBA Identification
Each HBA ships with several numbers clearly marked on the board. Record these
numbers before installation.
- IEEE address An IEEE unique 64-bit identifier used for system configuration.
- WWN Derived from the IEEE address; the FC industry uses the WWN for FC connectivity.
- Serial number Assigned by Emulex. Use this number when communicating with Broadcom® Technical Support.
NOTE: If the HBA has two ports, it has two IEEE addresses and two WWNs, one for each port.
Chapter 2: Installation
The Emulex HBA can be connected to fiber optic cables (used with embedded
optical transceivers). Additional information for these cable connections and
other installation procedures are described in the following sections.
2.1 Preparing the HBA for Installation
Before installing the HBA, perform one or both of the following procedures:
- Change the bracket to a low-profile version as explained in Section 2.1.1, Changing the Bracket.
- Disable or enable the Secure Firmware feature available on selected HBAs using the instructions in
Section 2.1.2, Setting the Secure Firmware Feature.
If changes to the HBA are not required, proceed to Section 2.2, Installing the
HBA.
2.1.1 Changing the Bracket
A standard, full-height PCIe bracket is factory-installed; however, a low-
profile bracket is included in the box with any HBA that supports the low-
profile bracket change. The low-profile mounting bracket is shorter than the
standard bracket: approximately 3.11 in. (7.9 cm) compared to 4.75 in. (12.06
cm) long.
To change the bracket, perform the following steps:
-
Some HBAs have optical transceivers embedded in their cage assemblies. These optical transceivers must be removed
before the bracket can be removed. If the HBA contains optical transceivers, continue with the following steps; otherwise, proceed to Step 4.
CAUTION! This is a delicate operation. Take care not to damage the optical transceiver. The HBA uses different types of optical transceivers. Figure 3 shows an example of one type with the bail (handle) extended.
Figure 3: Typical Optical Transceiver
-
To remove a transceiver, pull the bailout and down to release the latch and gently pull out the transceiver. Do not force it. After the latch is released, the transceiver slides out easily.
Figure 4 shows a transceiver with the latch released (bail extended) and another transceiver latched in place.
Figure 4: Releasing the Latch on an Optical Transceiver
Figure 5 shows an extracted transceiver and another transceiver latched in place.
Figure 5: Removing an Optical Transceiver
-
Observing ESD precautions, store the transceiver in an ESD-safe place.
-
Remove the mounting bracket screws and washers from the top of the HBA. Figure 6 shows the screws that are removed
Figure 6: Removing the Mounting Bracket
-
Remove the mounting bracket, and store it for future use.
-
Align the new mounting bracket tabs with the holes in the HBA.
CAUTION! Be careful not to push the mounting bracket past the grounding tabs on the transceiver housing. Make sure the LEDs are properly aligned with the holes in the mounting bracket. -
Reinstall the screws and washers that attach the HBA to the mounting bracket.
-
Reinstall the transceiver by sliding it into the housing. When the latch engages, it clicks. 9. Push the bail back into place.
2.1.2 Setting the Secure Firmware Feature
The LPe31000-series and LPe32000-series HBAs have a jumper that enables or
disables the Secure Firmware feature as required.
To update the firmware using a tool, such as the Emulex HBA Manager
application, boot utilities, or Elxflash utilities, there is no need to remove
the jumper. The Secure Firmware feature can remain enabled as long as the
update is from one secure firmware version to another secure firmware version.
To change the firmware version from a secure firmware version to an unsecured
firmware version, you must remove the jumper before updating the firmware.
NOTE: The Emulex OneCommand® Manager application has been renamed as the
Emulex HBA Manager application.
Replace the jumper after the firmware update is complete.
Figure 7 provides an example of a common location of the Secure Firmware
jumper.
Figure 7: Secure Firmware Jumper Location J3
2.2 Installing the HBA
To install the HBA, follow these steps:
-
Turn off the computer.
-
Remove the computer case.
-
For a stand-up HBA, remove the blank panel from an empty PCIe bus slot.
-
Insert the HBA into the selected slot. Press firmly until the HBA is seated.
NOTE: Make sure that the HBA is in an appropriate PCIe slot that does not interfere with other components or with the case to prevent damage to the HBA. -
Secure the HBA mounting bracket to the case with a panel screw or clip. 6. Replace the computer case and tighten the case screws.
The HBA is now installed in the server and is ready for an FC device.
2.3 Attaching Media
You can connect fiber optic cables to the HBA.
An HBA does not allow normal data transmission on optical links unless it is
connected to a compatible optical interface connection.
NOTE: Use short-range (SR), direct-connecting receptacle (DCR) multimode
fiber cable for interface connections to a network.
To attach media to the HBA, follow these steps:
-
Ensure that the cages have optical transceivers installed in them. If necessary, insert an optical transceiver into each cage.
Figure 8: Installing an Optical Transceiver
-
Insert an appropriate optical cable into the LC connectors on the HBA.
Figure 9: Connecting a Fiber Optic Cable
-
Connect the other end to the FC device.
You are ready to apply power to the system.
2.4 Applying Power
To apply power:
- Verify that the HBA is securely installed in the system.
- Verify that the correct media is attached.
- Plugin the computer and turn it on.
- Watch the LEDs for POST results.
2.5 Viewing the LEDs
You can view the green and yellow LEDs through openings in a stand-up HBA’s
mounting bracket. The yellow LED indicates a port activity or link speed, and
the green LED indicates firmware operation. Each port has a corresponding set
of yellow and green LEDs.
Figure 10: Optical HBA LED Indicators
The following table
summarizes POST conditions and results:
NOTE: For the link rate conditions, a 1s pause occurs when the yellow LED
is off between each group of fast blinks (2, 3, 4, or 5, depending on the
HBA). Observe the LED sequence for several seconds to be sure you have
correctly identified the pattern.
Table 1: POST Conditions and Results
Yellow LED | Green LED | State |
---|---|---|
Off | Off | No SFP module was installed or a boot failure occurred (dead board) |
On | Off | POST failure (dead board) |
Slow blink | Off | Boot failure after POST |
Flashing | Off | POST processing in progress |
Off | On | Failure in the common code module |
On | On | Failure in the common code module |
1 fast blink | On | Normal (link up at 2GFC) (legacy compatibility only) |
2 fast blinks | On | Normal (link up at 4GFC) |
3 fast blinks
4 fast blinks (LPe12002-M8 HBAs only)
| On| Normal (link up at 8GFC)
4 fast blinks| On| Normal (link up at 16GFC)
5 fast blinks| On| Normal (link up at 32GFC)
Off| Slow blink| Normal (link down)
Fast blink| Fast blink| Beaconing