Honeywell MI-D240CMOE Single Relay Module Installation Guide
- June 9, 2024
- Honeywell
Table of Contents
Honeywell MI-D240CMOE Single Relay Module
Dimension
This manual is intended as a quick reference installation guide. Please refer
to the control panel manufacturers installation manual for detailed system
information.
The installation must be carried out by expert personnel, that is, a person
with education or experience to identify hazards and take appropriate actions
to reduce the risk of injury to themselves and others.
GENERAL INFORMATION
The Morley series of modules are a family of microprocessor controlled interface devices permitting the monitoring and/or control of auxiliary devices. The MI-D240CMOE is an output module, providing 250VAC 5A rated voltage free contacts, both normally open and normally closed.
SPECIFICATIONS
- Operating Voltage Range: see S00-7100
- LED Cutoff Voltage: 16.5 VDC
- Maximum Standby Current (µA): 75µA – No Communication
- Fault Current: 5.5 mA (Yellow LED illuminated)
- Coil Activation/Deactivation Current: 76mA Maximum for 12ms
- Relay Contact Rating: 5A at 30VDC, 5A at 250VAC
- Isolator Features: see S00-7100
- Operating Temperature: 20°C to 60°C
- -Humidity: 5% to 95% Relative Humidity
- Maximum Wire Gauge 2.5 mm²
CAUTION: Disconnect loop power before installing modules or sensors. High voltages may be present on terminals 7 to 12.
INSTALLATION
Note: This module must only be connected to control panels using
compatible proprietary analogue addressable communication protocols for
monitoring and control.
Morley series modules can be mounted in several ways (See Figure 1):
An M200E-SMB custom low profile surface-mounting box. The SMB
Base is affixed to mounting surface, and then the module and cover are screwed onto the base using the two screws supplied. Box dimensions: 132 mm (H) x 137 mm (W) x 40 mm (D)
The DIN bracket on top allows mounting onto standard 35 mm x 7.5 mm “Top Hat” DIN rail inside a control panel or other suitable enclosure. Install and remove as shown in Figure 1:2. Wiring to all series Morley modules is via plug in type terminals capable of supporting conductors up to 2.5 mm
WARNING: Ensure that the correct terminals are used for the loop and switched voltage as damage may result from incorrect usage.
The module address is selected by means of rotary decade address switches (see
figure 3), accessed at the front of the module. A screwdriver should be used
to rotate the wheels to select the desired address. (Note: The number of
addresses available will be dependent on panel capability, check the panel
documentation for information on this).
Short Circuit Isolators All Morley series modules are provided with short
circuit monitoring and isolators on the intelligent loop. If required the
isolators may be wired out of the loop to facilitate the use of the modules on
high current loaded loops, for example if sounders are used. To achieve this,
the loop out positive should be wired to terminal 4 rather than terminal 2.
Note:
In order to meet the requirements of European Safety Standards, ensure that
all cables carrying voltages in excess of 48V are suitably fused.
Honeywell Morley-IAS Pittway Tecnologica S.r.l Via Caboto 19/3 34147 Trieste, Italy