Volthium Dongle Connection User Manual
- June 9, 2024
- Volthium
Table of Contents
Dongle Connection
USER’S MANUAL
VOLTHIUM MONITOR – BLUETOOTH APPLICATION
Volthium Monitor is the new generation application for your Volthium communication modules. Entirely made in Montréal (Québec), Canada. Download the application here:
DESCRIPTION OF THE FEATURES AND CONNECTION
DESCRIPTION OF THE DIFFERENT MODULES
-
Bluetooth dongle:
Has a total of 3x RJ45 female ports and a DC input port:
• The DC port (green) is used for the power supply. The accepted voltage is in the range of 10V to 59V.
• The RJ45 port, on the same side as the DC connector, is used in case only one battery is to be monitored with the Bluetooth module.
Do not connect a battery to this port if the Bluetooth module is used with the “Communication HUB” module.
• Series of 2 RJ45 ports (Daisy-Chain CAN)
– They are used to interconnect Volthium boxes on the CAN network.
For example; The “Communication HUB” box, which would be used to connect a battery bank (energy bank).
– Could also be used to connect the “Closing Loop”, which is a small black RJ45 connector. -
Communication HUB:
Has a total of 6 RJ45 female ports:
• Series of 4x RJ45 female ports on one side:
– For battery reading only.
• – Series of 2 RJ45 ports (Daisy-Chain CAN)
– They are used to interconnect Volthium boxes on the CAN network
– For example; The “Bluetooth Dongle” box, or the “Power Supply” box.
– They are also used to connect to an external device on the CAN bus, such as Victron VE.CAN
– Used to connect the “Closing Loop”, which is a small black RJ45 connector. -
Power Supply Module
Has a total of 2x RJ45 female ports and a DC input port.
• The DC port is used for the power supply. The accepted voltage is in the range of 10V to 59V.
• Series of 2 RJ45 ports (Daisy-Chain CAN)
– They are used to interconnect Volthium boxes on the CAN network
For example; The “Communication HUB” box, or the “Bluetooth Dongle” box.
– Use to connect the “Closing Loop”, which is a small black RJ45 connector.
GENERAL NOTE
We call a “Network”, the set of Volthium modules interconnected between them.
In a network of Volthium modules, a Closing Loop terminator RJ45 must be
installed in one of the CAN ports (“Daisy-Chain”). The selection of the port
is not important, in fact any CAN port of any module can be used to receive
the RJ45 Closing Loop Terminator.
EXAMPLE OF BLUETOOTH CONNECTION: 2X VOLTHIUM BATTERIES 12V100AH.
You will need to order the combo: Bluetooth Module & HUB.
In addition, you will need to order 1 XLR-RJ45 cable (male) in EXTRA on the
website.
In the delivery you will get:
-
Bluetooth dongle module, including
– Bluetooth module
– DC cable
– 1x 6-inch flat RJ45 cable
– 1x XLR – RJ45 male cable -
Communication HUB module
– HUB Module
– 1x 6-inch flat RJ45 cable
– RJ45 VE.CAN 6 feet cable
– Closing Loop terminator
BLUETOOTH CONNECTION: 2X VOLTHIUM 12V100AH BATTERIES
Instructions
- Connect the 2 batteries, from their XLR connector to the HUB module, for each battery. Make sure to plug them into ports 1-2 of the HUB module.
- Interconnect, via the CAN Daisy-CHAIN port, the HUB module box to the CAN Daisy-CHAIN port of the Bluetooth module using the flat black RJ45 cable.
- Connect the closing loop terminator to one of the CAN ports (this can be on the HUB module, or on the Bluetooth module).
- Connect the power supply with the DC cable from the batteries to the Bluetooth module.
- Download the application for your mobile: Volthium Monitor
BLUETOOTH CONNECTION: 1X VOLTHIUM BATTERY 12V 200AH YELLOW
Instructions
- Connect the battery via its RJ45 port (any of the 2, not important) to the HUB module using a standard RJ45 cable (you can use the flat black 6″ cable provided with the Bluetooth module).
- Connect the power supply with the DC cable from the batteries to the Bluetooth module.
- Download the application for your mobile:
BLUETOOTH CONNECTION + VICTRON: 2X VOLTHIUM 12V100AH BATTERIES.
Instructions
-
Connect the 2 batteries from their XLR connector to the HUB module using the XLR-RJ45 cable for each battery.
Make sure to plug them into ports 1-2 of the HUB module. -
Interconnect, via the CAN Daisy-CHAIN port, the HUB module box to the CAN Daisy-CHAIN port of the Bluetooth module using the flat black RJ45 cable.
-
Connect the closing loop terminator to one of the CAN ports (this can be on the HUB module, or on the Bluetooth module).
-
Connect the power supply with the DC cable from the batteries to the Bluetooth module.
-
Use the 6′ RJ45 CAN cable to connect one of the CAN ports, either from the Bluetooth box or from the HUB box, to the BMS-CAN (or VE.CAN port set to 500kb/s) of your Victron hardware.
– Also make sure to close the victron CAN bus circuit with the blue RJ45 connector provided by Victron.
– Note that the 6 foot RJ45 CAN flat cable has an identification. It just works in the direction expressed by the identification. -
Download the application for your mobile: – Volthium Monitor
DATA SHOWN IN VENUSOS
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>