NATIONAL PRIDE 2000S Equipment Reverse Osmosis System Three Phase Wall Mount User Manual
- June 9, 2024
- NATIONAL PRIDE
Table of Contents
- NATIONAL PRIDE 2000S Equipment Reverse Osmosis System Three Phase Wall
- INTRODUCTION
- SAFETY
- SYSTEM LOG INFORMATION
- SYSTEM OVERVIEW
- RO SYSTEM LAYOUT
- RO SYSTEM PLUMBING LAYOUT KEY
- RO ELECTRICAL LAYOUT
- SYSTEM LAYOUT
- SPOT FREE Production Unit
- STANDARD FEATURES
- RO SYSTEM REPLACEMENT PARTS
- TROUBLESHOOTING
- MAINTENANCE
- RO SYSTEM WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NATIONAL PRIDE 2000S Equipment Reverse Osmosis System Three Phase Wall
Mount
INTRODUCTION
This User’s Manual outlines installation, operation, maintenance and
troubleshooting details vital to the sustained performance of your system.
The test results which are included with this User’s Manual indicate your
system’s permeate and concentrate test results.
If your system is altered at the site of operation or if the feed water
conditions change, contact NPE to determine the proper recovery for your
application.
NOTE: IN ORDER TO MAINTAIN THE MANUFACTURER WARRANTY, AN OPERATING LOG MUST BE MAINTAINED AND COPIES WILL NEED TO BE SENT TO NATIONAL PRIDE EQUIPMENT FOR REVIEW.
NOTE: PRIOR TO OPERATING OR SERVICING THE RO SYSTEM UNIT, THIS USER’S MANUAL MUST BE READ AND FULLY UNDERSTOOD.
NOTE: IT IS UNSAFE TO OPERATE OR SERVICE THIS DEVICE WITHOUT FIRST READING AND UNDERSTANDING THE ENTIRE USER’S MANUAL. KEEP THIS MANUAL AND OTHER ASSOCIATED DOCUMENTATION FOR FUTURE REFERENCE.
SAFETY
This Safety section of this User’s Manual outlines the various safety headings used throughout this manual’s text and are enhanced and defined below:
- NOTE: INDICATES STATEMENTS THAT PROVIDE FURTHER INFORMATION AND CLARIFICATION.
- CAUTION: INDICATES STATEMENTS THAT ARE USED TO IDENTIFY CONDITIONS OR PRACTICES THAT COULD RESULT IN EQUIPMENT OR ANY TYPE OF PROPERTY DAMAGE.
- WARNING: INDICATES STATEMENTS THAT ARE USED TO IDENTIFY CONDITIONS OR PRACTICES THAT COULD RESULT IN INJURY OR LOSS OF LIFE. FAILURE TO FOLLOW WARNINGS COULD RESULT IN SERIOUS INJURY OR EVEN DEATH.
- WARNING: DO NOT REMOVE ANY CAUTION, WARNING, OR OTHER DESCRIPTIVE LABELS FROM THE EQUIPMENT.
- WARNING: DO NOT REMOVE ANY PAGES FROM THE SUPPLIED READING MANUALS OR OTHER INFORMATIONAL DOCUMENTS.
- WARNING: EYE PROTECTION SHOULD BE WORN AT ALL TIMES WHEN OPERATING THE RO SYSTEM AS UNIT HAS HIGH PRESSURE WATER LINES AND MEMBRANE HOUSINGS WHICH MAY LEAK IF FITTINGS LOOSEN OVER TIME.
- WARNING: UNIT INSTALLATION MUST ADHERE TO ALL LOCAL ELECTRICAL AND PLUMBING CODES.
- WARNING: ALL MAINTENANCE AND REPAIR ACTIONS ARE TO BE PERFORMED BY MAINTENANCE PERSONNEL WHO HAVE BEEN TRAINED AND FULLY READ THE DOCUMENTATION FOR ALL SYSTEM INFORMATION.
- CAUTION: TO AVOID ANY ELECTRICAL SHOCK HAZARD, DO NOT OPERATE THIS DEVICE WHEN COVERS OR CONTROLLER ENCLOSURE IS OPENED.
- CAUTION: ALL ELECTRICAL POWER MUST BE TURNED OFF AND THE LOCK OUT PROCEDURE MUST BE UTILIZED TO ENSURE ALL POWER IS SHUT OFF PRIOR TO SERVICING OR PERFORMING SYSTEM MAINTENANCE TO ANY POTION OF THE EQUIPMENT.
- CAUTION: DO NOT OPERATE THIS DEVICE IN AN EXPLOSIVE ENVIRONMENT OR IN THE PRESENCE OF FLAMMABLE MATERIALS.
- WARNING: MOVEMENT OR VIBRATIONS DURING SHIPMENTS MAY CAUSE CONNECTIONS TO LOOSEN. PLEASE CHECK ALL CONNECTIONS PRIOR TO TURNING ON THE POWER.
- WARNING: DO NOT OPERATE THIS UNIT IN ENVIRONMENTS WHERE TEMPERATURES MAY BE BELOW 40 DEGREES F OR ABOVE 90 DEGREES F.
- WARNING: IMPROPER WATER FLOW, WATER PRE-TREATMENT, MISUSE OR IMPROPER OPERATION OF THIS DEVICE WILL VOID THE MANUFACTURER’S WARRANTY.
- CAUTION: FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN DAMAGE TO EQUIPMENT OR PERSONAL INJURY.
OPERATING LIMITS
Minimum Feed Temperature | 85 | Maximum Free Chlorine PPM | 0 |
---|---|---|---|
Maximum Feed Temperature | 40 | Maximum TDS PPM | 1000 |
Minimum Ambient Temperature | 120 | Maximum Hardness | 0 |
Maximum Ambient Temperature | 40 | Minimum pH (Continuous) | 11 |
Minimum Feed Pressure | 85 | Maximum pH (Continuous) | 5 |
Maximum Feed Pressure | 45 | Minimum pH (Cleaning 30 Min) | 12 |
Maximum Operating Pressure | 120 | Maximum pH (Cleaning 30 Min) | 2 |
Maximum SDI Rating SDI | <3 | ||
Maximum Turbidity NTU | 1 |
SYSTEM LOG INFORMATION
FACTORY DATA
- Date Manufactured ____
- RO Model Number ____
- RO Serial Number _____
Factory Performance
- Feed Water __
- PPM Product Permeate _____
- PPM Product Rate _____ GPM
- Drain Rate ____
- PPM Inlet Pressure _____
- PSI Pump Pressure ____ PSI
- System Pressure ___ PSI
Installation Data
- Feed Water TDS ___ ppm TDS @ ____
- Hardness _____
- Iron __
- Misc. _____
- Product TDS __ ppm
- % TDS Rejection ___
- Product Rate __ gpm
- Drain Rate ____ gpm
- Operating Pressure Pre-Membrane _____ psi
- Pump Model Number ___
- Pump Serial Number ____
- Tested By _____Date __
- Approved By __Date __
SYSTEM OVERVIEW
National Pride Equipment has developed and manufactured a proprietary RO
System to provide a spot free rinse for car wash applications.
This RO System has been engineered to allow for a long longevity of issue free
operation and low life cycle cost for the operator. The system utilizes
commercial low temperature (high efficiency) RO membranes which operate at low
pressure. In addition, all the components (chlorine filter, sediment filter,
pumps, etc.) have been selected to improve the system reliability, minimize
energy use and reduce required maintenance.
Please review the entire Manual prior to installation, start-up, servicing or
operating the RO System. This manual will include step by step instructions,
general overview, replacement parts for the system and overall guidelines.
RO SYSTEM LAYOUT
RO SYSTEM PLUMBING LAYOUT KEY
-
Step 1
Tubes go from the Brine Tank to the Dual Water Softener (Blue) -
Step 2
Fresh Water Supply into Dual Water Softeners (Green)
Tubes from the Brine Tank to the Dual Water Softeners (Blue)
Soft Water Discharge from Dual Water Softener to Carbon Filter (Red) -
Step 3
Soft Water Discharge from Dual Water Softener to Carbon Filter (Red)
Carbon Filter Flex Line from Carbon Filter to RO Unit (Green) -
Step 4
Carbon Filter Flex Line from Carbon Filter to RO Unit (Green)
Flex Line from RO Unit to the Spot Free Storage Tank (Blue)
Concentrate Saver Flex line to Sewage (Orange)
Spot Free Re-Pressure Line
From Spot Free Pump Outlet to Rain Bar Solenoid Valves (Pink) -
Step 5
From Spot Free Re-Pressure Pump to Rain Bat Solenoid Valves. (Yellow)
RO ELECTRICAL LAYOUT
SYSTEM LAYOUT
Product Name | Product ID |
---|---|
1. Flo-Meter Non Adjustable | F-44500LE-8 |
2. Flo-Meter Adjustable | F-44500LA-8 |
3. TDS Controller | HMDPSC-60D |
4. Rear Mount Flange Gauge | GL400RF |
5. LED Indicator Light Green | IL-110-GREEN |
6. LED Indicator Light Red | 1L-110-RED |
7. Toggle Switch | XB5AD21 |
Product Name | Product ID |
---|---|
1. Pre Filter Housing | TW-AH0069 |
2. Pre Filter | TW2005 |
3. Pressure Gauge | GNL100B |
4. Membrane Housing | TW208419 |
5. Membrane | TW30XLE-4040 |
6. Pressure Switch | 69WR3 |
Product Name | Product ID |
---|---|
1. Float Switch | GG2DW2000 |
2. Pump | WW61050 |
SPOT FREE Production Unit
At National Pride, we are committed to bringing you premium grade equipment that is reliable, durable, and easy to operate. Our saving space design helps units fit into tight or small pump rooms and range from 2,000 to 12,000 gallons per day. Each unit is thoroughly tested before shipment, ensuring that you receive a product of the highest quality.
STANDARD FEATURES
- Stainless steel wall mount frame
- Built-in TDS meter
- 12” x 48” carbon tank
- Stainless steel multi-stage pump
- Float switch
- Heavy duty PVC membrane housings
- XLE 4040 membranes
- 5 Micron pre-filter and housing
- 1.5 cubic feet carbon de-chlorinator
- Float kit
- Pre-Filter
MODEL NO | GPD | HOUSING | MEMBRANE | AUTOFLUSH | HP |
---|---|---|---|---|---|
NPRO2000S | 2,000 | Heavy Duty PVC | (2) XLE – 4040 | Yes | Sta-Rite 1.0 HP |
NPRO4000S | 4,000 | Heavy Duty PVC | (2) XLE – 4040 | Yes | Sta-Rite 1.0 HP |
NPRO6000S | 6,000 | Heavy Duty PVC | (3) XLE – 4040 | Yes | Sta-Rite 2.0 HP |
NPRO8000S | 8,000 | Heavy Duty PVC | (4) XLE – 4040 | Yes | Sta-Rite 2.0 HP |
NPRO10000S | 10,000 | Heavy Duty PVC | (5) XLE – 4040 | Yes | Sta-Rite 3.0 HP |
NPRO12000S | 12,000 | Heavy Duty PVC | (6) XLE – 4040 | Yes | Sta-Rite 3.0 HP |
RO SYSTEM REPLACEMENT PARTS
Product ID # | Product Description |
---|---|
STR1008-BF6S | Stainless Wall Mount RO Production Unit |
69WR3 | Reverse Action Pressure Switch |
WW61050 | Washworld 1.5hp 3 Phase StarRite Solution Pump Razor |
F-44500LA-8 | Flow Meter 1/2” Adjustable |
F-44500LE-8 | Flow Meter 1/2” Non-Adjustable |
GL400RF | Pressure Gauge Liquid Filled 1/4” Rear Mount Flange Style |
MM28106 | Barstock Fittings Pipe Bushing 1/2” MPT x 1/4” FPT |
MM32022 | Barstock Fittings 3/4” Hose to 1/2” MPT |
MM28212 | Barstock Fittings Hex Nipple (MxM) 1/4” |
ASC8238T405-120 | ASCO 1/2” NC Valve 120v |
MM28215 | Barstock Fittings Hex Nipple (MxM) 3/4” |
MM28028 | Barstock Fittings Union Tee (FxFxF) 3/4” |
MM28109 | Barstock Fittings Pipe Bushing 3/4” MPT x 1/4” FPT |
MM32023 | Barstock Fittings Hose 3/4” x 3/4” MPT |
ALT5308901 | 1/2” Cord Grip |
ALT8113305 | Oring for 5308901 Cord Grip |
MCM7513K241 | 1/2” Cord Grip Conduit Locknut |
CIS808005 | 1/2” Sch 80 PVC Elbow |
CIS805005 | 1/2” Sch 80 PVC Tee |
D-RODECAL2000 | Decal Spot Free NPRO2000 |
D-9001 | Control Center Decal |
D-ETL | ETL Decal |
MM32022 | Barstcok Fittings 3/4” Hose to 1/2” MPT |
MM28027 | Barstock Fittings Union Tee (FxFxF) 1/2” |
MM23022 | Barstock Fittings 3/4” Hose to 1/2” MPT |
MM20092 | Male Elbow 90Dg; 1/2 Tube x 1/2NPT |
MM28106 | Basrtock Fittings Pipe Bushing 1/2” MPT x 1/4” FPT |
MM20082 | Male Elbow 90Dg; 1/4 Tube x 1/4 NPT |
H141206HLL | 14 x 12 x 6 Poly Enclosure, Hinged |
ABP-1412 | Aluminum Back Panel 14 x 12 |
SR2E201FU | 100-240VAC Smart Relay |
LC1D18G7 | Telemecanique Contactor |
LRD14 | 7-10A Overload Relay |
MM28106 | Barstock Fittings Pipe Bushing 1/2” MPT x 1/4” FPT |
MM28214 | Barstock Fittings Hex Nipple (MxM) 1/2” |
MM28154 | Barstock Fittings Long Pipe Nipple 1/2” x 2.5” |
Product ID # | Product Description |
--- | --- |
MM20055 | Nickel Plated Pushlkock Fitting 1/4” Tube x 1/4” MPT |
ASC88122403 | ASCO S Series Din Connector |
TW208419 | Axeon Membrane Housing Fiberglass 4” x 40” |
TW30XLE-4040 | RO Membrane Dimensions 4” x 40” |
NERCH900B | 4” Conduit Clamp |
IL-110-GREEN | LED Indicator 110v Green |
IL-110-RED | LED Indicator 110v Red |
3044076 | Phoenix UT2.5 Term Block |
0800886 | Phoenix End Bracket |
6047167 | Phoenix ATP-UT Partition Plate |
1050020-110 | Zack Marker Strip 1-10 |
1050020-1120 | Zack Marker Strip 11-20 |
CAFL4U-220 | Terminal Block w LED 220v |
AGA2 | 2 AMP Glass Fuse |
EPCAFL4U | End Plate |
MM28004 | Barstock Fittings 90 Dg Pipe Elbow (FxF) 1/2” |
9070T100D20 | SQD Transformer 110V Secondary |
PRO-STM7/8 | Single Tube Mount (Set) |
MM28044 | Barstock Fittings Female Pipe Cross 1/2” |
XB5AD21 | 2 POS NC Selector Switch |
MCM9565K27 | Square Finish Plug |
GG2DW2000 | Mechanical Switch – ABS Housing 13 AMP |
21534A | Float Switch Weight |
TW-AH0069 | Filter Housing 2.5 x 20 |
TW2005 | RO Membranes Sediment Filters 2.5” x 20” 5 Micron |
STRAB0060-SS | 3/4” Prefilter Stainless Steel Mounting Bracket |
GNL100B | Pressure Gauge Non Liquid Filled |
HMDPSC-60D | Basic Dual TDS Controller |
MM28225 | Barstock Fittings Male Hex Pipe Reducer 3/4” x 1/2” |
MM28111 | Barstock Fittings Pipe Bushing 3/4” MPT x 1/2” FPT |
CULL-CARBON2.75 | Culligan Non Back Washing Carbon with Cullar D+ |
SP12-HS | Hose Clamp 9-16” – 1-1/4” Stainless Steel |
MCM69915K55 | 3/4” Cord Grip |
83400N2 | Delran Receptacle Straight Male |
CZ14D68F012N | 90 Dg Female Cord Set |
MM28002 | Barstock Fittings 90 Dg Pipe Elbow (FxF) 1/4” |
MM20021 | Nickel Plated Pushlock Fitting 1/2” Tube Union Connector |
TROUBLESHOOTING
Symptom | Solution |
---|---|
Low RO Water Production | Check Water Pre-Treatment |
Equipment
Improperly pretreated water can cause the membrane to have low water
production. Check Pressure Pre-Membrane
if Pressure Pre-Membrane is not maintained between 120-200 psi, loss will
occur
Unable to Keep Pressure
Pre-Membrane Between 120-200 psi| Check Reject Control
Valve
With the RO running, shut off the reject control valve. Pressure should
climb above the minimal pressure. If pressure does not increase, pinch off RO
drain hose. If pressure still does not increase, the pressure pump needs to be
replaced. If the pressure does increase, the reject control valve needs to be
replaced.
Spot Free Water is Spotting| Check Product Water TDS
Test the product water as it is being produced. Sample the water as it
moves to the storage tank. If the TDS is high, it could mean the membrane has
been compromised. Check Product Water TDS
The storage tank is an atmospheric storage container which can make it
prone to the contamination. Routine cleaning of the tank will eliminate this
problem.
RO Display Shows TANK FULL When the Tank is Not Full| High Level
Float Switch is not Working
Using a jumper wire, jump the tank float terminals 15 & 16. If the RO does
change to RO running, check wires from control box to float switch. If wire is
OK, replace high level float switch.
Symptom| Solution
---|---
Production Pump Won’t Start| ****
No Power to RO System
Check RO Controller’s Smart Relay is working. If it is not working, check
the source power.
Blown Fuse in the Control Box
Check if either of the fuses look blown. If blown, replace the fuse.
RO Fault Condition Exists
The Production Pump will not start for the displays of TANK FULL, LOW FEED
PRESSURE or BAD FLOAT.
High Level Float Switch is not Working
Add a jumper wire to the tank float switch terminals 15 & 16.
If the RO pump does not stop replace the smart relay.
If the RO Pump stops, replace the high level float switch to fix the issue.
RO Display Shows High TDS| Check Product
Water TDS
Test the product water as it is being made. Sample the water as it goes to
the storage tank. If the TDS is high it could mean that the membrane has
fouled. Check Storage Tank TDS
The storage tank is an atmospheric storage container which can make it
prone to the contamination. Routine cleaning of the tank will get rid of this
problem.
MAINTENANCE
RO System Maintenance Log
The operation and maintenance of an RO machine requires regular data recording and routine preventative maintenance. It is vitally important that the daily log sheet be filled out during each operational shift of use. A startup sheet / log should be filled out containing the informational facts about the operation of your machine. These records are kept strictly for reference. If you have questions concerning the operation of your machine or the method of the data recording, contact the manufacturer.
NOTE: A log is included with this manual.
RO System General Maintenance Guide
As a part of the routine maintenance program, it is suggested that performance
data of your
RO System is recorded on a regular basis. By recording the performance data,
diagnosing and performance problems at a later date will be much easier.
Replace Pre-Filter Cartridges
The standard rule is that once a month the 5 Micron pre-filter should be
replaced.
The frequency can very depending on the production demands of the RO System.
This filter protects the membrane elements from particles, which me be located
in the feed water.
NOTE: A Pressure drop of 8 psi or more during operation indicates that the pre-filter cartridge needs replacing. Use filters rated at 5 micron or less.
Membrane Element Replacement
Membrane life expectancy will very from site to site depending on the water quality. TDS reading of 30 or less is considered to be spot free. Anything above this reading, the membranes should be replaced.
RO SYSTEM WARRANTY
National Pride Equipment RO System
National Pride Equipment warrants to the original consumer / purchaser against
defects in material and/or workmanship from the date of original Manufacture
as follows:
Limited Warranty, covering materials and workmanship for 1 year from the date
of installation, subject to user’s to compliance with manufacturers operating
and maintenance instructions. Filter and Membranes are excluded by Warranty,
and National Pride Equipment responsibility is limited to any Warranty
provided by the filter or membranes manufacturer.
National Pride Equipment shall not be held liable for any special, incidental
or consequential damages, and will at its option, repair or replace any
defective components.
Any parts used for replacement are warranted for the remainder of the original
warranty period. THIS WARRANTY DOES NOT COVER DEFECTS CAUSED BY ACCIDENT,
FIRE, FLOOD, ACTS OF GOD, MISUSE, MISAPPLICATION OR NEGLECT.
Shipping expenses to National Pride Equipment at 905 Hickory Lane, Mansfield,
Ohio 44905 are the responsibility of the consumer. National Pride Equipment
will ship the repaired or new component at the consumer’s expense and will not
be responsible for any labor charges or other costs resulting from the removal
or installation of the repaired or replaced part.
NPE RO System User’s Manual
NPRO2000S
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>