NOTIFIER MP120K Series 120 VAC Adapter Mounting Plate Owner’s Manual
- June 9, 2024
- NOTIFIER
Table of Contents
MP120K(A) Series
120 VAC Adapter Mounting Plate
General
System Sensor’s MP120K(A) mounting plate is designed to use 120 VAC to power
SpectrAlert® Advance horns, strobes, horn/strobes, chimes, and chime/strobes.
The MP120K(A)features an easy plug in design and has been fitted with a power
supply that converts the 120VAC to nominal 24V FWR. The mounting plate may be
used for indoor or outdoor applications. For indoor applications, complete
field wiring and attach the mounting plate to a four inch square back box.
Attach the horn, strobe or horn/strobe, chime or chime/ strobe to the mounting
plate by inserting the product’s tabs in the mounting plate’s grooves. The
device will rotate into position, locking the product’s pins into the mounting
plate’s terminals. The device will temporarily hold in place with a catch
until it is secured with a captured mounting screw. For outdoor applications,
the MP120K(A) must be installed using the SpectrAlert Advance weatherproof
back box and outdoor listed notification appliance.
Features
- Operates at 120 VAC Indoor / Outdoor use
- Compatible with all two -wire SpectrAlert Advance devices
- Compatible with 4½ × 4½ × 21/8½ electrical boxes and System Sensor weatherproof back box
- Plug-in design
- Paint cover provided to protect wiring terminals
Specifications
Architectural/Engineering Specifications: 120 VAC mounting plate model
MP120K(A) shall be listed to UL 464 for fire protective signaling systems. The
mounting plate shall power a two-wire SpectrAlert® Advance horn, strobe,
horn/strobe, chime or chime/strobe from a 120 VAC supply converted to nominal
24V FWR. For indoor applications the mounting plate shall be installed in a 4½
× 4½ × 21/8½ junction box, for outdoor applications the mounting plate shall
be installed using the proper SpectrAlert Advance outdoor weatherproof back
box and outdoor listed notification appliance.
PHYSICAL/OPERATING SPECIFICATIONS
Standard Operating Temperature: –40°F to 151°F (–40°C to 66°C)
Humidity Range: 10 to 93% non-condensing (indoor products)
Nominal Voltage: Regulated 120 VAC
Operating Voltage: Range 96–132 VAC
Current Draw From AC Line: 150 mA max.
Product Line Information
MP120K: 120 VAC Adapter Mounting Plate. MP120K(A) may be used with any of
the following products, at all horn and strobe settings: P2R, P2RH, P2RK,
P2RHK, P2W, P2WH, SR, SRH, SRK, SRHK, SW, SWH, PC2R, PC2RH, PC2RK, PC2RHK,
PC2W, PC2WH, SCR, SCRH, SCRK, SCRHK, SCW, SCWH, HR, HRK, HW, SR-P, SW-P,
SRH-P, SWH-P, P 2 R – P, P 2 W- P, P 2 R H – P, P 2 W H – P, S C R – P, S C W-
P, S C R H – P, SCWH-P, PC2R-P, PC2W-P, PC2RH-P, PC2WH-P, SR-SP, SRH-SP, P2R-
SP, P2RH-SP, SCW-SP, SCWH-SP, PC2W-SP, PC2WH-SP, CHR, CHW, CHSR, CHSW.
MP120KA: Same as MP120K, but with ULC listing.
NOTE: “A” suffix indicates ULC Listed.
Agency Listings and Approvals
These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.
- UL Listed: S4011.
- ULC Listed: S4011.
- CSFM: 7300-1653:195.
- MEA: 582-06-E.
Notifier® is a registered trademark of Honeywell International Inc.
©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of
this document is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone:
203-484-7161, FAX:
203-484-7118.
www.notifier.com