Honeywell Sensepoint XCD Toxic and Oxygen Gas Detector Instruction Manual

June 9, 2024
Honeywell

Honeywell Sensepoint XCD Toxic and Oxygen Gas Detector
LOGO

Honeywell Sensepoint XCD Toxic and Oxygen Gas Detector

Honeywell Sensepoint XCD Toxic and Oxygen Gas Detector
PRODUCT

One-Stop Shop

  • Flammable (catalytic or infrared), toxic and oxygen versions available
  • New and retrofit applications
  • Suitable for indoor or outdoor use
  •  Stainless steel or aluminium explosion-proof housing options
  • IP66 as standard

Proven and Reliable Sensor Technology

  •  SurecellTM electrochemical sensors
  • Poison immune infrared sensors
  •  Poison resistant catalytic bead sensors
  • Long life sensors

Global Approvals

  • US and Latin America, European, Canadian and Asian
  • Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards

Easy to Use

  •  User friendly and intuitive tri-colour backlit display with digits, bar graph and icons
  •  Fully configurable via magnetic switches
  •  Optional remote sensor mounting*
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance
  • MODBUS communications for remote diagnostics/configuration*

Cost Effective

  •  Common transmitter platform
  • Minimal training required
  •  Reduced spares
  • Non-intrusive, one-man operation
  • Plug-in sensor replacement
  • MODBUS multi drop option offers cabling savings*

Simple Installation

  •  Plug-in display module removes to give access to terminal area
  • Integral mounting bracket
  •  2 x M20 or ¾” NPT cable/conduit entries (certification dependent)
  • Removable plug/socket type terminal blocks for ease of wiring
  • Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
  •  Remote sensor mounting kit*
  •  Remote sensor gassing kit
  •  Duct mounting kit
  •  Calibration gas flow housing
  •  Collecting cone
  •  Contact Honeywell Analytics for availability of these options.

Typical Applications

  •  Industrial manufacturing facilities
  • Power plants
  •  Waste water facilities
  •  Utilities
  •  Food and beverage production
  • Refineries and chemical plants
  •  Onshore oil and gas terminals
  •  Production platforms
  •  Exploration and drilling

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non- intrusive operation and reduces routine maintenance time and costs. A tri- colour backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm. All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and MODBUS. The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter’s LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance. Sense point XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either conduit or cable with suitable mechanical protection. Two M20 or ¾”NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit, collecting cone and remote mounting sensor socket.
Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy to replace plug-in sensors, downtime is also reduced and on-going costs are minimised through the use of poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented Surecell™ toxic sensors.Honeywell
Sensepoint XCD Toxic and Oxygen Gas Detector 01

  1.  Cover
  2.  Display module
  3. Terminal area
  4. Blanking plug
  5. Transmitter
  6.  Plug-in XCD sensor
  7. Sensor retaining ring
  8. Integral mounting plate
  9. Weather protection assembly
  10. Cable/conduit entry (x2)
  11.  Certification label

Sensepoint XCD Overview

There are three different types of the XCD transmitter for use with three different families of sensors. The mV type transmitter is for use with the mV family of XCD sensors including catalytic sensors to detect flammable gases in the range 0-100%LEL and infrared (IR) sensors for detection of Hydrocarbon gases in the range 0-100%LEL and 0-100%Vol*, as well as Carbon Dioxide (CO2) in the range 0-2%Vol. The EC type transmitter is for use with the EC family of XCD sensors including Carbon Monoxide (CO), Hydrogen Sulfide, (H2S) and Hydrogen (H2). The Oxygen transmitter is for use with the Oxygen (O2) XCD sensors. A transmitter can auto-recognize any sensor from within its sensor family. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly.

Sensepoint XCD Sensor Families, Gases and Ranges

| Gas| User Selectable Full Scale Range| Default Range| Steps| Selectable Cal Gas Range| Default Cal Point
Sensor Family| mV| Catalytic Bead Sensors| 30 to 70% of selected full scale range|
Flammable 1 to 8| 20.0 to 100.0%LEL| 100%LEL| 10%LEL| 50%LEL
Infrared Sensors|
Methane| 20.0 to 100.0%LEL| 100%LEL| 10%LEL| 50%LEL
Methane| 20 to 100%Vol.
| 100%Vol.| 10%Vol.| 50%Vol.
Carbon Dioxide| 0.1 to 2%Vol.| 2%Vol.| 0.1%Vol.| 1%Vol.
EC| Electrochemical Sensors|
Hydrogen Sulfide| 10.0 to 100.0ppm| 50.0ppm| 0.1ppm| 10ppm
Carbon Monoxide| 100 to 1,000ppm| 300ppm| 100ppm| 100ppm
Hydrogen| 1,000ppm only| 1,000ppm| n/a| 500ppm
O 2| Oxygen| 25.0%Vol. only| 25.0%Vol.| n/a| 20.9%Vol. (Fixed)| 20.9%Vol.

Honeywell Sensepoint XCD Toxic and Oxygen Gas Detector
02 Ready, Steady, Go!
Sensepoint XCD uses three instantly recognizable ‘traffic light’ colours to indicate its status. The large tri-colour backlit LCD  is steady green to indicate normal operation, flashes yellow to indicate a fault/warning and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.Honeywell
Sensepoint XCD Toxic and Oxygen Gas Detector 03XCD is the right choice for a variety of demanding industrial applicationsHoneywell Sensepoint XCD Toxic and Oxygen Gas Detector
04 Honeywell Analytics Serves Every Business
We offer the industry’s most complete range of gas detection products and services to meet all customer needs.

Commercial
Vulcain-brand gas detection from standalone units to fully engineered, multi- point systems, all offering cost-effective regulatory compliance

  • Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories

Industrial
Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies

  • Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial

Portables
Single or multi-gas Lumidor and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments

  • Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first esponder teams, remote fleets

High Tech/Government
A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paper- based solutions (MDA Scientific) offering detection down to parts per billion

  • Applications: semiconductor manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research laboratories, emergency response

Technical Services

24/7 global network includes post-sales service and Systems Integration teams

  •  Emergency call out, service contracts, on/off-site repair, training and commissioning
  •  Complete range of spares, consumables and accessories

Find out more
www.honeywellanalytics.com

Contact Honeywell Analytics:
Americas
Honeywell Analytics Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8210
detectgas@honeywell.com

Technical Services
ha.us.service@honeywell.com
www.honeywell.com

Europe, Middle East, Africa
Life Safety Distribution AG
Weiherallee 11a
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com

Asia Pacific
Honeywell Analytics Asia Pacific

508, Kolon Science Valley ()

187-10 Guro-Dong, Guro-Gu
Seoul, 152-050
Korea
Tel: +82 (0)2 2025 0307
Fax: +82 (0)2 2025 0329
analytics.ap@honeywell.com

Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently Issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
H_XCD D01082_V1_US 5/09
2009 Honeywell Analytics

References

Read User Manual Online (PDF format)