waterway 63767 Power Defender 1.40 Hp Dual Voltage Variable Speed Pump Owner’s Manual
- June 4, 2024
- waterway
Table of Contents
- waterway 63767 Power Defender 1.40 Hp Dual Voltage Variable Speed Pump
- IMPORTANT SAFETY INSTRUCTIONS
- WIRING
- POWER DEFENDER 1.40 HP DUAL VOLTAGE VARIABLE SPEED MOTOR WARNINGS &
- PUMP STRAINER BASKET
- WINTERIZING
- CARE OF ELECTRIC MOTOR
- PROTECT FROM HEAT
- PROTECT AGAINST DIRT
- PROTECT AGAINST MOISTURE
- PUMP DISASSEMBLY
- PUMP REASSEMBLY / SEAL REPLACEMENT
- POWER DEFENDER 1.40 HP DUAL VOLTAGE PUMP REPLACEMENT PARTS
- RESTARTING INSTRUCTIONS & PRIMING THE PUMP
- TROUBLESHOOTING
- REDUCED FLOW AND/OR HEAD
- WARRANTY
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
waterway 63767 Power Defender 1.40 Hp Dual Voltage Variable Speed Pump
Owner’s Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS • SAVE THESE INSTRUCTIONS
WARNING: Before installing this product, read and follow all warning
notices and instructions accompanying this pump. Failure to follow safety
warnings and instructions can result in severe injury, death, or property
damage.
ATTENTION INSTALLER: This manual contains important information about
the installation, operation, and safe use of this product. This information
should be given to the owner/operator of this equipment.
NOTE: When pump is mounted permanently within 5 ft. of the inside walls
of a swimming pool, you must use No. 8 AWG or larger conductor to connect
to bonding conductor lug.
WARNING: To reduce the risk of injury, do not permit children to use this
product unless they are closely supervised at all times.
CAUTION: For hot tubs and spas, do not install within an outer enclosure
or beneath the skirt of a hot tub or spa unless so marked.
WIRING
WARNING: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage to property. Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock.
SUPPLY WIRE SIZES (AWG)
Size and Length by Horsepower
HP| 115 Volts| 230 Volts
| 50 Ft.| 100 Ft.| 150 Ft.| 50 Ft.| 100 Ft.| 150
Ft.
1/3| 14| 14| 12| 14| 14| 14
1/2| 14| 12| 10| 14| 14| 14
3/4| 12| 12| 10| 14| 14| 14
1| 12| 10| 8| 14| 14| 14
1 1/2| 10| 10| 8| 14| 14| 12
2| 10| 8| 8| 14| 12| 12
3| –| –| –| 12| 12| 12
- Make sure all electrical breakers and switches are turned off before wiring motor.
- Make sure that the wiring voltage matches the motor voltage (230v or 115v). If they do not match the motor will burn up.
- Choose a wire size from Chart 1. When in doubt use a heavier gauge (larger diameter) wire. Heavier gauge will allow the motor to run cooler and more efficient.
- Cut wires to the appropriate length so they don’t overlap or touch when connected to the terminal board.
- Make sure all electrical connections are clean and tight.
- Permanently ground the motor using the correct wire size and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical service ground.
- Bond the motor to the pool structure in accordance with the National Electrical Code. Use a solid No. 8 AWG or larger copper conductor. Run a wire from the brass external bonding clamp to the pool bonding structure.
- Connect the pump permanently to a circuit. Make sure no other lights or appliances are on the same circuit.
NOTE: If the pump is installed below the water level of the pool, close return and suction lines prior to opening hair and lint pot on pump. Make sure to re- open valves prior to operating.
POWER DEFENDER 1.40 HP DUAL VOLTAGE VARIABLE SPEED MOTOR WARNINGS &
ASSISTANCE
Please store this instruction sheet and the A.O. Smith
user interface booklet in a safe place for future use.
Please carefully read the entire enclosed
booklet for the operation and troubleshooting of
the Power Defender 140 Dual Voltage.
PUMP STRAINER BASKET
This unit, sometimes referred to as the “Hair and Lint Pot”, is the unit in front of the volute. The lint pot must be installed using only teflon tape on the threads. Do not use liquid chemical thread sealant. The basket inside the chamber must be kept clean of leaves and debris at all times. View basket through the “See Through Lid” to inspect for leaves and debris. Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and heater and also put an abnormal stress on the pump motor which would result in a costly repair bill.
WARNING: DO NOT open the strainer pot if pump fails to prime or if pump has
been operating without water in the strainer pot. Pumps operated in these
circumstances may experience a build up of vapor pressure and may contain
scalding hot water. Opening the pump may cause serious personal injury. In
order to avoid the possibility of personal injury, make sure the suction and
discharge valves are open and strainer pot temperature is cool to touch, then
with extreme caution.
CAUTION: To prevent damage to the pump and filter and for proper
operation of the system, clean pump strainer and skimmer baskets
regularly.
** WARNING: THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATION SYSTEM (e.g. LOCK RING, PUMP, FILTER, VALVES, ETC) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.**
-
Turn off motor.
-
Relieve pressure in the system.
-
Turn the lid in a counter-clockwise direction until it stops.
-
Lift lid and remove basket.
-
Put the debris from the basket into the trash and rinse out the basket. If the basket is cracked, it should be replaced.
-
Replace the basket and fill the pump pot and volute up to the inlet port with water.
-
Clean the cover, O-ring and sealing surface of the pump pot. Grease the O-ring with Teflon or silicone.
-
Reinstall the lid (Figure 2).
-
Make sure the lid O-ring is properly placed. Seat the lid then turn clockwise until hand tight (DO NOT over tighten with tools) (Figure 3).
-
Turn the power “ON” at the house circuit breaker. Reset the pool time clock to the correct time.
-
Open the manual air relief valve on top of the filter.
-
Stand clear of the filter. Start the pump.
-
Bleed air from the filter until a steady stream of water comes out. Close the manual air relief valve.
WINTERIZING
CARE OF ELECTRIC MOTOR
**** If the air temperature drops below 35º F. the water in the pump can
freeze and cause damage. Freeze damage is not warrantable.
To prevent freeze damage follow the procedures listed below.
- Shut off electrical power for the pump at the house circuit
- Drain the water out of the pump case by removing the two drain plugs from the Store the plugs in the pump basket.
- Cover the motor to protect it from severe rain, snow, and ice.
- Do not wrap the motor in It will cause condensation and rust on the inside of the motor.
PROTECT FROM HEAT
- Shade the motor from the
- Any enclosure must be well ventilated to prevent
- Provide ample cross
PROTECT AGAINST DIRT
- Protect from any foreign matter or splashing
- Do not store (or spill) pool chemicals near the
- Avoid sweeping or stirring up dust near the motor while it is
- If a motor has been damaged by dirt it voids the
PROTECT AGAINST MOISTURE
- Protect from splashing pool
- Protect from the weather.
- Protect from lawn
- If a motor has become wet – let it dry before Do not allow the pump to operate if it has been flooded.
If a motor has been damaged by water it voids the motor warranty
NOTE: DO NOT wrap motor with plastic or other air tight materials. The motor may be covered during a storm, for winter storage, etc., but NEVER when operating or expecting operation.
WARNING: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage to property. Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock.
WARNING: DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to touch, then with extreme caution.
PUMP DISASSEMBLY
CAUTION: Be sure not to scratch or mar the polished seal faces. Seal will
leak if faces are damaged.
All moving parts are located in rear sub-assembly of this pump. Tools
required:
- 1/2 inch open end wrench
- 9/16 inch open end wrench
- Flat and Phillips head screwdrivers
To remove and repair the motor sub-assembly perform the following procedures.
- Turn off the pump circuit breaker at the main
- Drain the pump by removing the drain
- Remove the 6 bolts that hold the main pump body (strainer pot/ volute) to the rear sub-assembly.
- GENTLY pull the two pump halves apart, removing the rear sub-
- Remove the
- Hold the impeller securely in place and remove the impeller lock screw by using a Phillips head The screw is a left- handed thread and loosens in a clockwise direction.
- Remove the shaft cap located at the back of the motor and hold the shaft secure with a flat-head screwdriver (Century) or 7/16 inch open-end wrench (Franklin) .
- To unscrew the impeller from the shaft, twist the impeller counter
- Remove the four bolts from the seal plate to the motor, using a 9/16 inch
- Place the seal plate face down on a flat surface and tap out the carbon/spring
- Clean the seal plate, seal housing, and motor
PUMP REASSEMBLY / SEAL REPLACEMENT
CAUTION: The polished and lapped faces of the seal could be damaged if not handled with care.
- When installing the replacement ceramic/carbon seal, use silicone sealant on the metal portion, before pressing into the seal
- Before installing the ceramic section of the seal into the impeller, be sure the impeller is Use a light density soap and water to clean the seal. Press the seal into the impeller with your thumbs and wipe off the ceramic and carbon faces with a clean cloth.
- Remount the seal plate to the
- Screw the impeller onto the motor
- Screw in the impeller lock screw (counter-clockwise to tighten).
- Remount the diffuser onto the seal
- Grease the diffuser O-ring.
- Assemble the motor sub-assembly to the strainer pot-pump DO NOT tighten down any of the bolts until all 6 bolts are in place and finger tight.
- Fill the pump with
- Reinstall the pump lid by turning clockwise until hand tight ( DO NOT over tighten with tools).
Prime the system; see Priming the Pump
POWER DEFENDER 1.40 HP DUAL VOLTAGE PUMP REPLACEMENT PARTS
Part No. | Qty | Description | Part No. | Qty | Description | |
---|---|---|---|---|---|---|
1 3P0V360 | 1 | Motor | 15 805-0238 | 1 | 0-Ring-238 | |
2 819-0035 | 3 | Bolt .375-16 X .875 Long | 16 319-1420 | |||
1 | Diffuser Plate | |||||
3 672-1350 | 1 | Motor Support Supra Max | 17 715-1200 | |||
2 | 3/8” Quarter Slot Plug (Sd Wet End) | |||||
4 319-1500 | 1 | Motor Base | 18 805-0014 | 2 | O-Ring, |
-014
5 819-0013| 2| Screw Slot Hex Washer 1/4” X 1_1/4”| | 20
319-1430| 1| Basket Assy
6 820-0017| 6| 3/8” Flat Washer Type B, Pool Pumps| | 21
805-0436| 1| O-Ring, 6”Trap Lid
7 319-1700| 1| Handle| | 22 319-4100| 1| Lid Assembly,
6”Trap
8 311-1450| 1| Face Plate| | 26 310-7410| 1| Impeller
Assy
9 711-1400| 1| Gasket, Face Plate| | 27 315-2410| 1|
Pump Housing – 2” X 2” Npt
10 319-3100B| 1| Pump Seal Set-Viton| | 28 820-0017-1| 6|
3/8”Washer, Split Lock
11 711-4300| 1| Washer, Impeller| | 29 820-4280| 6| Brass
Insert, 3/8-16 Unc Housing
12 819-4360| 1| Screw Phil. Pan Head Left Hand 1/4-20 X 1”| |
30 819-0016| 6| 3/8”-16 X 2” Lg Hex Head
13 310-7470| 1| Diffuser Assy| | | |
14 819-0018| 2| #4-40 Uncs Bolt Schs| | | |
RESTARTING INSTRUCTIONS & PRIMING THE PUMP
CAUTION: DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. If this occurs, the damaged seal must be replaced. ALWAYS maintain proper water level in your pool. If the water level falls below the skimmer opening, the pump will draw air through the skimmer, losing the prime and causing the pump to run dry, resulting in a damaged seal.
If the pump is installed below the water level of the pool, close return and
suction lines prior to opening hair and lint pot on pump. Make sure to re-open
valves prior to operating.
The pump strainer pot must be filled with water before the pump is initially
started. Follow these steps to prime the pump. For
2-speed pumps: Pump should run on high-speed for priming.
- Remove the pump
- Fill the pump strainer pot with
TROUBLESHOOTING
FAILURE OF PUMP
-
Pump will not prime, too much Remedy:
-
Check suction piping and valve glands on all suction gate
-
Secure lid on pump strainer pot and make sure lid gasket is in
-
Check water level to make sure skimmer is not drawing
-
Pump will not prime, not enough Remedy:
-
Make sure suction lines, pump strainer, and pump volute are full of
-
Make sure valve on suction line is working and open (some systems do not have valves).
-
Check water level to make sure water is available through
REDUCED FLOW AND/OR HEAD
-
Air pockets or leaks in suction Remedy:
-
See item 1a of this section
-
Reassemble the pump lid onto the strainer The pump is now ready to prime.
-
Open the manual air relief valve on top of the filter, and stand clear of the
-
Turn on the switch or time
-
When water comes out of the manual air relief valve, close the The system should now be free of air and circulating water to and from the pool.
NOTE: Self-priming pump may take up to 3 1/2 minutes to reach a lift height of 10 feet.
- Clogged Remedy:
- Turn off electrical power to the pump.
- Remove the bolts holding the volute to the seal
- Slide the motor and seal plate away from the
- Remove the
- Clean debris from If debris cannot be removed, complete the following steps:
* Remove left hand threaded bolt and
* Remove, clean and reinstall
* Reinstall left hand threaded bolt and
5. Reinstall the diffuser and diffuser O-ring.
6. Reinstall motor and seal plate into
7. Tighten bolts
- Pump strainer Remedy:
- Clean suction trap.
WARRANTY
For product registration visit:
www.waterwayplastics.com.
For Warranty questions or claims please contact point of purchase.
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>