Waterway EX2 Viper Pump
Specifications
- Model: 48/56 FRAME EXECUTIVE, EX2, & VIPER PUMP
- Installation: Permanently installed pools only, not for storable pools
- Electrical requirements: Must be installed by qualified electricians
- Motor: Waterway male union threads
- Wiring: Conform to local, state, and national codes
Pump Connections Installation
- Place pump on a level surface below water level.
- Install shut off valves on both the inlet and outlet for future maintenance.
- Ensure the installation area is clear of direct water and has adequate floor drainage.
- Protect the pump from excessive moisture.
Motor Wiring
- Ensure power is turned off before working on electrical connections.
- Wiring must adhere to local, state, and national codes.
- Refer to the wiring diagram on the motor nameplate for correct wiring.
- Verify applied voltage matches the rated voltage on the marking plate.
- For Safety Class 1 equipment, connect the pump to the protective conductor.
Troubleshooting
- MOTOR WON’T START: Check voltage at terminals with voltmeter.
- MOTOR HUMS WON’T START: Troubleshoot potential issues as per manual.
- MOTOR IS NOISY: Investigate possible causes based on provided guidelines.
- MOTOR RUNS, THEN STOPS: Check voltage and other components as directed.
Maintenance
Regularly check for proper operation, leaks, and unusual noises. Follow
troubleshooting steps if issues arise.
FAQ
Q: What should I do if my pump runs but there is no flow?
A: Check shut off valves, ensure pump is below water level, and inspect for
air lock issues.
48/56 FRAME EXECUTIVE, EX2, & VIPER PUMP INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS & WARNINGS SAVE THESE INSTRUCTIONS PLEASE READ AND FOLLOW ALL INSTRUCTIONS
ALL ELECTRICAL INSTALLATIONS SHOULD BE PERFORMED BY QUALIFIED ELECTRICIANS
-
2-SPEED MODELS: DO NOT wire both speeds to run simultaneously. If supply cord is damaged, replace only with original replacement equipment available from authorized dealer.
The pump is to be supplied through a residual current device (RCD) with a rated residual operating current not exceeding 30mA. -
Potential risk of fire, electrical shock, or injury to persons if misused.
-
DO NOT install within an outer enclosure or beneath the skirt of the spa unless so marked.
-
WARNING: To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
-
CAUTION: This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity.
PUMP CONNECTIONS INSTALLATION INSTRUCTIONS
LOCATION: Place pump on level surface. Pump must be installed below water
surface. Shut off valves should be installed on both the inlet and outlet of
the pump for future maintenance. Installation area should be clear of any
direct water and have adequate floor drainage. Pump should be protected from
excessive moisture.
The inlet and outlet have Waterway male union threads. Use Waterway tailpiece
assemblies for best connection. These unions allow the pump to be removed for
service without disturbing the plumbing. HAND TIGHTEN UNIONS ONLY!
DO NOT use pipe dope. Use only Teflon tape or other sealing compounds approved
for use with plastic. Some pipe dopes not approved for use with plastic will
cause stress cracking of plastic parts. New installations often require
a plumbing inspection. This inspection is usually conducted using city water
pressure. A pressure regulator should be used when preforming this test and
should not exceed 40 PSI during the pressure test. The filter and pump are
under pressure. Insure that all air is removed during the pressure test.
FAILURE TO FOLLOW THESE INSTRUCTIONS EXPLICITLY CAN RESULT IN PERSONAL INJURY.
MOTOR WIRING
-
Before working on any electrical connections be sure that the power is turned off.
-
All wiring must conform to local, state and/or national codes.
-
All wiring must conform to wiring diagram on the motor nameplate or on the back of the terminal cover.
-
Applied voltage must correspond to the rated voltage as indicated on the marking plate.
-
FOR SAFETY CLASS 1 EQUIPMENT: It is mandatory to connect the pump to the protective conductor (grounding connector) of the earth-grounded main power supply.
FOR EQUIPOTENTIAL BONDING: It is also possible in addition to use the external terminal on the body to realize an equipotential bonding with other earthed metallic parts. -
DO NOT ground to a gas supply line.
-
Ground motor prior to connecting electrical power.
-
For disconnection from the supply, a circuit breaker having a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring according to the wiring rules. Cord and plug provided with pump is intended to be used with mating spa pack connector.
-
improper grounding can cause serious injury and damage to the motor, voiding the warranty.
-
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
For Wiring Instructions Refer to Wiring Diagram on Motor.
Ensure wiring circuit agrees with diagram and leads are securely tight.
2200 East Sturgis Road, Oxnard CA 93030 Phone 805.981.0262 Fax 805.981.9403 www.waterwayplastics.com waterway@waterwayplastics.com
TROUBLESHOOTING
ASSEMBLY DRAWING
EXPLODED VIEW
© Copyright 2008 Waterway Plastics