GE current Evolve EWAS A Series Wall Pack LED Outdoor Lighting Installation Guide
- June 9, 2024
- GE current
Table of Contents
GE current Evolve EWAS A Series Wall Pack LED Outdoor Lighting
BEFORE YOU BEGIN
- Read these instructions completely and carefully.
- Save these instructions for future use.
WARNING
- Risk of electrical shock. Disconnect power before service installation, or maintenance of the product.
- Risk of injury or damage. The unit will fall if not installed properly. Follow installation instructions.
CAUTION
- Risk of injury. Wear safety glasses and gloves during installation and servicing.
- Risk of injury. The luminaire should be mounted so that prolonged staring into the luminaire at a distance closer than 0.50m is not expected.
- Store packaged units in a covered dry area
- Check for damage
- Do not impact
- Do not stack
Mounting
- Loosen screws to remove the back for mounting
- Apply gasket if mounting on smooth surfaces
- Fasten to J-Box with user-supplied screws
WARNING
- Risk of Injury or Damage: Select user-supplied wall anchors and anchor fasteners suitable for the wall construction and the fixture’s mounting hole diameters. Ensure a minimum per-anchor pull-out-strength of 10 times (10X) the fixture weight and install per the manufacturer’s instructions.
- Fixture may be direct mounted using wall anchors.
- Locate and drill holes in wall surface of recommended diameter for user-supplied anchors.
- Fasten plate and torque screws to manufacturer’s recommendations to achieve rated anchor strength.
- If wiring through conduit, remove desired plug and secure conduit.
- If supplied, locate button-photocontrol on preferred side.
- If supplied, locate external occupancy sensor on preferred side.
- Caulk upper edge and sides on rough surfaces
- Attach tether from top to back housing tab.
CAUTION
- Risk of shock or damage. Follow applicable national and local electrical codes
- Risk of damage. Verify supply voltage and wire insulation temperature rating match nameplate requirements
CAUTION
- Risk of shock or failure. Reconnect any wires disconnected during mounting
Wiring
- ( Standard or Internal Occ Sensor Option) Connect supply leads to fixture and backplate ground leads.
- ( Button Photocontrol Option ) Connect supply leads to a fixture, Button PE, and backplate ground leads.
WARNING
-
Risk of Failure. An unswitched AC power source of 100VAC to 277VAC is required for proper EMBB charging and operation. An Illuminated (color?) LED
indicator light indicates AC power is applied -
(EMBB Option) Connect supply leads to fixture, EMBB, and backplate ground leads.
-
(External Occ Sensor) Connect supply leads to fixture, sensor, and backplate ground leads.
Button Up
- If the fixture is inverted rotate it upright
- Hook housing upper edge on the back
- Re-tighten the screws to secure the housing
Controls
- Verify if the unit has a programmable occupancy sensor
- Refer to the FSIR-100 datasheet for programable settings
- Aim FSIR-100 at fixture and program settings.
INFORMATION
For more information on programming and the FSIR-100 please visit W attStoppers® website:www.legrand.us/wattstopper
Cleaning
- Use mild soap
- Rinse with cool low pressure water.
- Wipe dry with clean soft cloth
CAUTION
Risk of Damage. Do not use soap/detergent containing aromatic hydrocarbons
CAUTION
Disposal Risk. Luminaires with Emergency Battery Backup (EMBB) option contain LiFePo batteries requiring proper waste disposal or recycling. Dispose in accordance with state and federal regulations.
SPECIFICATIONS
LUMINAIRE
- EWAS
APPROX. NET WEIGHT
- <14 lbs (6.4 kg)
DIMENSIONS
- 12.2 x 10.8 x 4.7 in (310 x 273 x 120 mm)
IP RATING/CLASSE IP
- Optical: Std – IP66
RECOMMENDED MOUNTING HEIGHT
- 8-30 ft (2.4-9.1 m)
OPERATING TEMPERATURE
- 40° to/à 40°C
- 20° to/à 40°C (EMBB)
FCC Statements
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. This Class [A] RFLD
complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est
conforme à la NMB-005 du Canada.
Note : This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
-
Questions: Web: gecurrent.com
-
Phone: 1-866-855-8629
-
All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.
-
All specifications are subject to change without notice.
-
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation,
operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the
matter should be referred to GE current. -
© 2023 Current Lighting Solutions, LLC. Todos los derechos reservados. GE y el monograma de GE son marcas registradas de General Electric Company y son usados bajo licencia. La información se encuentra sujeta a cambios sin previo aviso.
-
Todos los valores son de diseño o típicos al momento de ser medidos bajo condiciones de laboratorio.
References
- LED Commercial Lighting and Lighting Controls | Current - GLI Brands
- Evolve® | Current - GLI Brands
- Wattstopper Lighting Control Systems