FORT ‎RH-RP-12A 4 Pack 4 Inch Led Recessed Light 5000K Daylight Instruction Manual

June 9, 2024
Fort

FORT ‎RH-RP-12A 4 Pack 4 Inch Led Recessed Light 5000K Daylight

FORT-‎RH-RP-12A-4-Pack-4-Inch-Led-Recessed-Light-5000K-Daylight-
PRO

CONSTRUCTION

4-inch LED gimbal & 4 /6 inch Recessed round slim panel with integral LEDs. Isolated Class 2 external driver installed inside the junction box. one driver for every fixture required. Power Factor >0.95. LED fixture and driver are TYPE IC rated-approved for direct contact with insulation. Pot light housing is NOT required even for insulated celling.

  1. LEVITON 6672
  2. LEVITON 667 4
  3. LEVITON DSL06
  4. LEVITON DSM 10
  5. LUTRON DVWCL-153PH
  6. LUTRON TGCL-153PH
  7. LUTRON-DVW-600PH-W H-CSA
  8. LUTRON SCL-153PH-WH-C
  9. LUTRON CTCL-153PDH-WH-C
  10. LUTRON CT-600PH
  11. LUTRON MA-T530GH
  12. LUTRON DVCL-153P
  13. LUTRON MACL-153M
  14. ELECTRN/ART 40201
  15. LEVITON 6633-P
  16. LEVITON6613
  17. LEVITON 66EV
  18. LEVITON DDE06
  19. LUTRON SELV-300P
  20. LUTRON DVSCELV-300P
  21. LUTRON SELV300P
  22. LUTRONEL V DVELV-300P
  23. LUTRON SLV-600P-IV
  24. LUTRON S-600HP
  25. LUTRONDV-600PR
  26. LUTRON TG-600PR
  27. LUTRON CTCL-153PDH
  28. LUTRON 153MR-WH
  29. LUTRON RDL06

ALL FIXTURE MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE ELECTRICAL CODES

INSTALLATION

  1. Cut a hole for the lamp. The plate is mounted on the board.
  2. Open the cover of the junction box. Push and remove one of the knockouts on the side plate. Tighten the connector by hand. Do not attach the junction box to anything so you can pull it through the ceiling opening in case you need to service the driver in future. Install with standard 16 cable connector. Use double connector for daisy chaining multiple drivers. Insert line voltage feed into the cable connector. And splice same colour wires using quick connector. Close the cover of the box.
  3. Pull the spring clip on the fixture up and through the ceiling hole and place the fixture in the hole making sure the spring clips are holding securely.

OPTIONS FOR LOCATING DRIVER

  1. Locate next to the fixture-run line voltage wiring to the junction box and “daisy chain” to the junction boxes of the fixtures.
  2. or install all drivers at one location and use low voltage extension cables to the fixture. Use only extensions provided by the manufacturer. Available jumper cables are6 “(1.8m) and 20″(6m). Cables are linkable. Maximum run should not exceed 40″(12m).

DIMMING: We recommend LED/CEL dimmers that have a low rang adjustment dial. After all Fixtures are connected to the dimmer, adjust the dial to the lowest position before the lights start to flicker or shut down. This depends on the local voltage and number of fixtures per dimmer. For a typical LED dimmer rated for 150W LED load the maximum number of fixtures per dimmer is 12
WARNING: DO NOT USE ANY OTHER DRIVERS EXCEPT THE DRIVERS THAT ARE INCLUOED WITH THE FIXTURE; DO NOT CONNECT MULTIPLE FIXTURES TO ONE DRIVER; DO NOT OPEN THE LIGHT FIXTUER AND THE PLATES OF DRIVER. NO SERVICEABLE PARTS MANUFACTURER’S LIMITED WARRANTY.

Hole-cutting Size

FORT-‎RH-RP-12A-4-Pack-4-Inch-Led-Recessed-Light-5000K-Daylight-
\(4\)

  • 6″ round cutout / 6″ decoupe ronde / 6″ recorte redondo
  • 4″ round cutout/ 4″ decoupe ronde / 4″ recorte redondo
  • 3″ round cutout/ 3″ decoupe ronde / 3″ recorte redondo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Fort User Manuals

Related Manuals