FORT RH-RP-12A 4 Pack 4 Inch Led Recessed Light 5000K Daylight Instruction Manual
- June 9, 2024
- Fort
Table of Contents
FORT RH-RP-12A 4 Pack 4 Inch Led Recessed Light 5000K Daylight
CONSTRUCTION
4-inch LED gimbal & 4 /6 inch Recessed round slim panel with integral LEDs. Isolated Class 2 external driver installed inside the junction box. one driver for every fixture required. Power Factor >0.95. LED fixture and driver are TYPE IC rated-approved for direct contact with insulation. Pot light housing is NOT required even for insulated celling.
- LEVITON 6672
- LEVITON 667 4
- LEVITON DSL06
- LEVITON DSM 10
- LUTRON DVWCL-153PH
- LUTRON TGCL-153PH
- LUTRON-DVW-600PH-W H-CSA
- LUTRON SCL-153PH-WH-C
- LUTRON CTCL-153PDH-WH-C
- LUTRON CT-600PH
- LUTRON MA-T530GH
- LUTRON DVCL-153P
- LUTRON MACL-153M
- ELECTRN/ART 40201
- LEVITON 6633-P
- LEVITON6613
- LEVITON 66EV
- LEVITON DDE06
- LUTRON SELV-300P
- LUTRON DVSCELV-300P
- LUTRON SELV300P
- LUTRONEL V DVELV-300P
- LUTRON SLV-600P-IV
- LUTRON S-600HP
- LUTRONDV-600PR
- LUTRON TG-600PR
- LUTRON CTCL-153PDH
- LUTRON 153MR-WH
- LUTRON RDL06
ALL FIXTURE MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE ELECTRICAL CODES
INSTALLATION
- Cut a hole for the lamp. The plate is mounted on the board.
- Open the cover of the junction box. Push and remove one of the knockouts on the side plate. Tighten the connector by hand. Do not attach the junction box to anything so you can pull it through the ceiling opening in case you need to service the driver in future. Install with standard 16 cable connector. Use double connector for daisy chaining multiple drivers. Insert line voltage feed into the cable connector. And splice same colour wires using quick connector. Close the cover of the box.
- Pull the spring clip on the fixture up and through the ceiling hole and place the fixture in the hole making sure the spring clips are holding securely.
OPTIONS FOR LOCATING DRIVER
- Locate next to the fixture-run line voltage wiring to the junction box and “daisy chain” to the junction boxes of the fixtures.
- or install all drivers at one location and use low voltage extension cables to the fixture. Use only extensions provided by the manufacturer. Available jumper cables are6 “(1.8m) and 20″(6m). Cables are linkable. Maximum run should not exceed 40″(12m).
DIMMING: We recommend LED/CEL dimmers that have a low rang adjustment
dial. After all Fixtures are connected to the dimmer, adjust the dial to the
lowest position before the lights start to flicker or shut down. This depends
on the local voltage and number of fixtures per dimmer. For a typical LED
dimmer rated for 150W LED load the maximum number of fixtures per dimmer is 12
WARNING: DO NOT USE ANY OTHER DRIVERS EXCEPT THE DRIVERS THAT ARE
INCLUOED WITH THE FIXTURE; DO NOT CONNECT MULTIPLE FIXTURES TO ONE DRIVER; DO
NOT OPEN THE LIGHT FIXTUER AND THE PLATES OF DRIVER. NO SERVICEABLE PARTS
MANUFACTURER’S LIMITED WARRANTY.
Hole-cutting Size
- 6″ round cutout / 6″ decoupe ronde / 6″ recorte redondo
- 4″ round cutout/ 4″ decoupe ronde / 4″ recorte redondo
- 3″ round cutout/ 3″ decoupe ronde / 3″ recorte redondo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>