Please read this installation manual completely before installing the product.
The appliance shall be installed in accordance with national wiring regulations.
Please retain this installation manual for future reference after reading it thoroughly.
Simple Dry Contact Original instruction
LG Electronics Inc.
EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
Manufacturer: LG Electronics Inc. Changwon 2nd factory, 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA

Important Safety Instructions

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product.

WARNING
It can result in serious injury or death when the directions are ignored.

CAUTION
It can result in minor injury or product damage when the directions are ignored.

WARNING

  • Installation or repairs made by unqualified persons can result in hazards to you and others.
  • Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.
  • The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
  • Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Installation

  • Be sure to request to the service center or installation specialty store when installing products. It will cause fire or electric shock or explosion or injury.
  • Request to the service center or installation specialty store when reinstalling the installed product. It will cause fire or electric shock or explosion or injury.
  • Do not disassemble, fix, and modify products randomly. It will cause fire or electric shock.
  • Be sure to turn off power before installation. It will cause electric shock.
  • Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
  • Always perform grounding. Otherwise, it may cause electrical shock.
  • You need to use a safely insulated power supply which follows IEC61558-2-6 anc NEC Class2. If you do not follow, It may cause fire, electric shock, explosion or injury.
  • Securely attach the electrical part cover to Module. If the electric part cover of Module is not attached securely, it could result in a fire or electric shock due to dust, water, etc.
  • Make the connections securely so that the outside force of the cable may not be applied to the terminals. Inadequate connection and fastening may generate heat and cause a fire.

In-use

  • Do not place flammable stuffs close to the product. It will cause fire.
  • Do not allow water to run into the product. It will cause electric shock or breakdown.
  • Do not give the shock to the product. It will cause breakdown when giving the shock to the product.
  • Request to the service center or installation specialty store when the product becomes wet. It will cause fire or electric shock.
  • Do not give the shock using sharp and pointed objects. It will cause breakdown by damaging parts.
  • Do not touch the board when the power is connected. It can cause a fire, electric shock, explosion, injury and problem to the product.
  • Unplug the unit if strange sounds, smell, or smoke comes from it. Otherwise, it may cause electrical shock or a fire.
  • The appliance must only be supplied at safety extra low voltage corresponding to the marking on the appliance.
  • This appliance is not intended to be accessible to the general public.

CAUTION
In-use

  • Do not clean using the powerful detergent like solvent but use soft cloths. It will cause fire or product deformation.
  • Do not press the screen using powerful pressure or select two buttons. It will cause product breakdown or malfunction.
  • Do not touch or pull the lead wire with wet hands. It will cause product breakdown or electric shock.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Overview

LG Dry Contact is a solution for automatic control of air conditioning system at the owner’s behest.
In simple words, it’s a switch which can be used to turn the unit On/Off after getting the signal from external sources like key-in lock, door or window switch etc specially used in Hotel rooms.
It’s a small PCB that either can be fit inside the control box of Indoor unit or can be outside the unit in a plastic case if there is no sufficient space inside the Indoor unit.
Apart from simple installation, it can also be linked to Central Controller via Indoor unit PI485 pcb. For this, all connecting wires & an additional small pcb for looping is also provided along with Dry Contact.
Dry Contact can be used in two ways.

  1. It can be used to actually turn On/Off the system on receiving the signal from the source.
    In this case, user doesn’t need to use remote controller anymore to turn On/Off the system.
    However all the further settings like temperature, fan speed, mode etc can be done through remote controller only.

  2. Other way is almost similar as above but in this case, after getting the On signal from the external source, user has to turn On the system from remote controller only. Dry contact just activates the system.
    However system can be turned Off directly from the external source. So only On mode is different here.

So in both of above conditions, system can’t be operated without signal from external source which prevents unnecessary use of system & facilitates its operation only when its required.
These settings can be selected from the remote controller whose details have been explained in the later part of this manual
So depending upon the requirement, Dry Contact offers a variety of applications to suit the customer’s requirement in the best possible way.
h If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.

  • Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
  • Qualified service technician is only possible to access to product.

Minimum cross-sectional area of conductors

LG-PDRYCB000-Air-Conditioner-1 LG-PDRYCB000
-Air-Conditioner-2

Part Description

PDRYCB000 (PCB + Case)

LG-PDRYCB000-Air-Conditioner-3

  • CN_POWER : Connector
  • CN_CC : Indoor PCB Connector
  • CN1 : Central Controller Connector
  • CN_DRY(L) :
    • DRY CONTROLLER Connector
  • CN_DRY(SIG) :
    • DRY CONTROLLER Connector
  • CN_DRY(ERROR CHECK) : ERROR Check Display Connetor
  • CN_DRY(OPER STATE) : Operation Display Connector
  • FUSE : 250 V / 3.15 A
Accessory

LG-PDRYCB000-Air-Conditioner-4

*Note

  • These cable using for connection between Dry contact and Indoor unit.
  • So before using these things Please check the connector type first and use cables on proper indoor unit.

Installation

  1. Loosen and remove two screws that secures the product.

  2. Remove the front metal case by pressing the marked points.

  3. Position the rear case to the direction (left or right) towards to the connector

  4. Remove 4 screws, for strapping wires.

  5. Secure the rear case on the installation place using the supplied fixing screws.

  6. Remove knock out shapes on the rear case (2-sided) according to the connector’s size and direction.

  7. Connect the connection wires properly according to the connection. When connecting CN-POWER and CN_DRY(L) to the power cable in the terminal block, make sure to put them inside the square hole of the Clamp as shown in the picture.

  8. Set the switch according to the setting method. (Refer to the instruction)

  9. Combine top part of the metal case with the back side of the metal case.

  10. Hang the front of the case to the rear case hook and tighten the fixing screws on the bottom part.
    LG-PDRYCB000-Air-Conditioner-13

Note

  1. Install the product on flat surface and install anchoring screws at more than 2 places. Otherwise the central controller may not be anchored properly.
  2. Do not tighten anchoring screws too tightly. It may cause deformation of the case.
  3. Do not deform the case at random. It may cause malfunction of the central controller.

Step 1
Connect CN-CC with Indoor PCB by the cable(provided)

  • Connection of Dry contact only
    LG-PDRYCB000-Air-Conditioner-14

  • Connection of Dry contact & LG Central Controller in case of single constant models.
    LG-PDRYCB000-Air-Conditioner-15

Single Only

  • When you install single product this PCB have to add.

Step 2
Connect CN_DRY with Control Unit . (Fix SUB PCB into the proper location.)

  • To apply power source through PCB
    LG-PDRYCB000-Air-Conditioner-16

  • To apply power source directly to external source
    LG-PDRYCB000-Air-Conditioner-17

Administrator Guide

Function
It gives selection whether to turn ON the unit directly or not from the external source. The selection can be made by pressing SET/CLEAR button of the wireless remote controller 3 times within 3 minutes of resetting the unit with facing it towards the unit. (This function availability depends on indoor unit model)

  1. To turn ON the unit directly from the external source
  2. Not to turn ON the unit directly from the external source. Only to activate the system.

*Note
This function(Dry contact mode setting) doesn’t work in some wired remote controller. For more information, please refer to manual of wired remote controller.

If the power gives out, the Air conditioner may be run to before state after power returns because Air conditioner’s function of interruption of electric power compensation.

Disposal of your old appliance(as per e-waste Rules)

When this crossed out wheeled bin symbol is depicted on the product and its operator’s manual, it means the product is covered by the e-waste Management and Handling Rules , 2011 and are meant to be recycled, dismantled, refurbished or disposed off.

Dos

  • The product is required to be handed over only to the authorized recycle for disposal.
  • Keep the product in isolated area, after it becomes non-functional/unrepairable so as to prevent its accidental breakage.

Don’t

  • The product should not be opened by the user himself/herseW, but only by authorized service personnel.
  • The product is not meant for re-sale to any unauthorized agencies/scrap dealer/kabariwalah.
  • The product is not meant for mixing into household waste stream.
  • Do not keep any replaced spare part( s) from the product in exposed area.

Any disposal through unauthorized agencies/person will attract action under Environment (Protection) Act 1986 .

This product is complied with the requirement of Hazardous Substances as specified under Rule 13 (1) & (2) of the E-Weste (Management &
Handling) Rules, 2011.

To locate a nearest collection centre or call for pick-up (limited area only) for disposal of this appliance, please contact Toll Free No. 1800-180-9999 for details. All collection centre and pick up facilities are done by third parties with LG Electronics India Pvt. Ltd. Merely as a facilitator.
For more detailed information , please visit: http://www.lge.com/in.

www.lg.com
Copyright © 2018 LG Electronics Inc. All Rights Reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>