ABESTORM Hurricane 140P 275 Pints Commercial Dehumidifiers
Guardian SN90
Abestorm Solutions INC.
ADD: 8605 SANTA MONlCA BLVD#79525 WEST
HOLLYWOOD, California, 90069 USA
E-mail: sales@abestorm.com
Safety Notes
- Always connect your dehumidifier using a grounded electrical connection (as required for all electrical appliances). The use of non-grounded wiring will void the warranty.
- Your dehumidifier should only be repaired by a qualified technician.
- Do not use the dehumidifier in standing water. If there is a chance that the dehumidifier has been flooded, unplug the unit, remove the cover, and allow it to dry completely before proceeding.
- Do not insert objects or your fingers into the inlet or discharge.
- Do not use water to clean the exterior of the dehumidifier. To clean unit, unplug from power, then use a damp cloth to wipe the exterior.
- Do not stand on dehumidifier or place objects on it. Do not use with extension cord or plug adapter.
- Unless otherwise noted, all maintenance should be done with the unit powered off.
- The unit must be used in the upright position.
- Do not restrict airflow in to or out of the unit. This may cause the unit to overheat.
Warranty Registration
Your dehumidifier comes with an extensive warranty.
For future reference, write down the model, serial number, and date of
purchase for your dehumidifier. This information is necessary for seeking
assistance in the future and can be found on the data label on the side of the
unit.
Model Number : Abestorrn Hurricane 140P
- Serial Number: ____
- Date of Purchase: ____
For additional questions concerning your dehumidifier, contact your local installer or call Abestorrn at .
Specifications
- Capacity @ 80°F/60%RH: 140 Pints Per Day
- Airflow: 440CFM
- Operating Temp. Range: 35.6-105°F
- Operating Relative Humidity Range: 35%-90%
- COP: 2.75 L/kWh
- Refrigerant: R410A
- Amperage Usage: 8.3 Amps
- Power Supply: 115V/60Hz/Single Phase
- Outlet Requirement: 15 Amp
- Sound Level: 60 dBa
- Item Dimensions (LxWxH): 22.05 x 23.62 x 37.40 inch
- Package Dimensions (LxWxH): 29.29 x 29.29 x 41.73 inch
- ETL Listed: Yes
How It Works
Abestorm dehumidifiers use an integrated humidistat to monitor the conditioned space. When the relative humidity goes above the selected setpoint, the dehumidifier will energize. Air is then drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.
Installation
- Place dehumidifier on a level surface.
- Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a level surface.
- If unit has been turned or flipped so that the compressor did not remain upright, place the unit on a level surface and wait a minimum of 2 hours before proceeding.
- Set up the drain line
- Locate the dehumidifier near a suitable drain (16.4′ drain hose included}. Allow for proper drainage and routing of needed drain pipes
- Connect the drainpipe to the quick connector of the dehumidifier before placing the drain pipe into the sewer
- The dehumidifier is equipped with a built-in drainage pump to support the drainage height of 14.7′.
- Plug dehumidifier into grounded 15 amp circuit.
Key Functions
-
Power Key
Use this button to turn the dehumidifier on and off. Press once to turn machine on .You will hear one beep and the Power light will luminate green Press the power button second time and you will hear one beep as the machine shuts down. Note that there is a one minute fan delay on shutdown. -
Arrow Buttons
- Use the up and down arrow buttons to set the desired humidity setpoint on the dis play screen.
- The setpoint can be any number between 36-90%.Creating a set point means that when the indoor humidity is lower than the set point, the machine will stop automatically. Conversely, when the indoor humidity is higher than the set level, the unit will operate.
NOTE: The humidity levels displayed are approximate only (+/-5%).
-
Continuous Mode
- To switch into continuous mode, set the humidity below 36%.At this point the Cont. light should illuminate green on the display board to indicate you have successfully switched to continuous mode. The display screen will show “Co”.
- When set to continuous, the dehumidifier will run constantly, regardless of the humidity level. To stop the dehumidifier from running, turn the unit off or switch back to normal humidistat operation. To stich back to normal humidistat operation, simply move the setpoint above 36%.
-
Manual Drain Button [ ]
- If you need to store or move your dehumidifier, press the “Drain” button to remove water from the integral pump’s reservoir.
Indicator Lights
-
Humidity Display Screen
- The display screen has two functions:
- When the unit is powered on, it shows the humidity of the space.
- While setting the desired humidity level, the screen will show the set humidity.
After a brief delay, the display will revert to current humidity level.
-
Power Indicator Light
- This light indicates that the unit is properly powered on and ready to operate. Always make sure this unit is “off” prior to performing any service.
- When the power light is blinking, it means that the unit has reached the humidity setpoint.
-
Continuous Mode/Auto Defrost Light
- When this light illuminates green, it indicates that the dehumidifier is set to continuous operation mode.
- When the light glows red, it means the unit is in auto defrost mode and clearing the evaporator coil of any ice buildup.
-
Compressor Light
- When the compressor light glows red, it indicates the compressor has been initiated but is currently warming up.
- Once the compressor light switches to green, it indicates the compressor is in working status.
Remote Control Instructions
Abe storm Dehumidifiers can be controlled using an optional remote accessory.
The remote connects to your dehumidifier via a 25′ CAT 5 cable, with the
integrated sensor giving you multiple options for monitoring surrounding
conditions.
Example #1- Install the dehumidifier in the laundry room and duct it into the
living room.
Mount the remote in the living room and use the remote sensor.
Example #2- Install the dehumidifier in your crawl space with the remote
mounted in your garage.
NOTE: The symbols indicated below only show when the remote is powered
on.
-
On/Off (Power)Button
Press the on/off button and the machine will start running (two beeps). Press the button again to turn the machine off. -
Up Button / Down Button
Use the Up and Down arrow buttons to adjust the humidity level. -
Mode M
Use the Mode button to switch between dehumidification and a ducted application- The symbol on the display board indicates the sensor on the remote control is being utilized.
- The symbol on the display board indicates the sensor on the dehumidifier is being utilized.
-
Temperature T
Press the temperature button to display the current temperature on the screen. Press the button again to turn off the dis – play. -
Continuous C
Press this button to switch the unit into continuous mode. Cont. will appear on the display to indicate continuous mode. -
Drain Pump p
Pressing the drain pump button will remove water from the pump reservoir, so the unit can be safely moved or stored.
NOTE: THIS FUNCTION IS ONLY AVAILABLE ON THE GUARDIAN SNS90 MODEL.
Operating Instructions
-
Start the machine
- Press the power key to turn the dehumidifier on.
-
Adjust the settings
- Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%).
-
Stop the machine
- Press the power button again and the dehumidifier will stop.
Note that the fan will continue to operate for 1 minute after the unit has shut off.
DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP.
- Press the power button again and the dehumidifier will stop.
-
Water Drainage
-
The Abestorm Hurricane 140P has an integrated condensate pump. During normal operation, the 140P will automatically drain as required.
-
If you would like to store or move your unit, press the drain button to drain water from the pump reservoir.
The drain will operate for 15 seconds each time the button is pushed.
It may be necessary to push the button more than once.
Unit Diagram
Maintenance
For more detailed instructions, visit www.abestorm.com
WARNING: Always unplug the unit before doing any maintenance.
Cleaning the Machine Body
- Use a soft, damp cloth to clean the exterior of unit. Do not use any soap or solvents
Coil Maintenance
- Once per year, clean the coils with an approved coil cleaner.
The coil cleaner should be a self-rinsing, foaming, cleaner, such as WEB® Coil Cleaner
Cleaning the Filter
- Unplug the unit.
- For Pre Filter:
- Remove pre filter from inlet of machine.
- Vacuum or wash with warm water (no soap).
- For MERV-10 Filter
- Replace as necessary- we recommend checking the filters at least 1x/year
Electrical Access
- Unscrew the 7 screws on the front panel.
- Remove the 4 screws on the control board cover.
Pump Maintenance
Your Abestorm Hurricane 140P is equipped with an integral condensate pump
designed to pump water from the dehumidifier out to the desired drain.
The pump requires routine maintenance that is not covered by the warranty.
Preventative maintenance is necessary to prevent issues from dirt and slime
that may accumulate in the drain system.
This includes the drain pan, hose to the condensate pump, pump reservoir, pump
head assembly, and discharge tubing.
Removing the Pump
- Remove the 7 screws on the side panel and set panel aside.
- Remove the screw holding the pump in place.
- Undo the 3 pump electrical quick connects and 1 drain quick connect
- Insert a flat head screwdriver into the notch on the side of the pump.
This will allow you to gently lift the pump off its reservoir (the reservoir remains attached to the unit).
Basic Pump Cleaning
Complete about once per year, depending on environment
-
Unscrew the 7 screws on the front panel. Press the drain button to drain the reservoir.
-
Disconnect power to the dehumidifier.
-
Mix a 16 ounce solution of bleach (1 oz bleach+ 15 oz water) OR vinegar (4 oz white vinegar+ 12 oz water).
-
Pour the cleaning solution into the drain tray at the base of the coils.
If any cleaning solution gets on the coils, flush with water. -
Allow solution to soak for 15 minutes.
-
Reconnect the dehumidifier to power.
-
Fill the reservoir with water (16-32 ounces) and flush/cycle the pump at least 2x.
-
If the drain line is still filled with debris, repeat process. If drain line still does not appear clean, move on to Advanced Cleaning.
-
Press the drain button to drain the water from the reservoir (a wet-dry vacuum or towels can be used to remove any remaining water).
-
Unplug the dehumidifier and remove the cover so you have access to the pump.
-
Remove the pump head from the reservoir by unscrewing the screw. Wipe reservoir clean with a paper towel.
-
Reassemble pump.
-
Mix a 16 ounce solution of bleach (1 oz bleach+ 15 oz water) OR vinegar (4 oz white vinegar+ 12 oz water).
-
Pour the cleaning solution into the drain tray at the base of the coils.
If any cleaning solution gets on the coils, flush with water. -
Allow solution to soak for 15 minutes.
-
Reconnect the dehumidifier to power.
-
Fill the reservoir with water (16-32 ounces) and flush/cycle the pump at least 2x.
Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the following steps:
- Tum off the unit and allow it to dry.
- Complete steps 1-3 in Advanced Pump Cleaning to clean out the pump reservoir.
- Wrap and secure the power cord.
- Cover the filter mesh.
- Store in a clean, dry space.
Troubleshooting
Symptom | Cause | Solution |
---|---|---|
Display is Blank | Poor Connection | Verify that both ends of the power cord are |
plugged in.
Power Outage| Reset power.
NoAirFlow| Filter is Dirty| Clean the filter.
Air Inlet or Outlet is Blocked.| Clear the blockage.
Trouble Code: E1| Humidity Sensor or Communication Error| Check to ensure that
the sensor wire is connected at both ends, if no issues are visible, the
sensor may be faulty.
Trouble Code: E4| Problem with Pump| Verify that the pump is properly
installed and functioning. If so, unplug the unit for two minutes, then
restart.
Trouble Code: LO| Room Temperature is below 35.6°F| Increase the room
temperature so it is within operation range (above 35.6°F). If error still
display, check sensor.
Trouble Code: HI| Room Temperature is above 105°F| Decrease the room
temperature so it is within operating range (below 105°F). If error still
displays, check the sensor.
ES Trouble Code| Refrigerant Leak| Contact your installer for
assistance.
Pump Alarm- E4 Error Code
**UNIT WILL NOT FUNCTION UNTIL ERROR CODE IS CLEARED.
If E4 (pump alarm) is shown on the display, complete the following steps:
- Reset the unit by unplugging the power cord and then reconnecting it.
- Manually check to see if the pump is operational by pressing the drain button. Check if the pump energizes and de-energizes properly. Additionally, check to see if any water purged from the system.
- If you haven’t cleaned the system recently, check the discharge line for an obstruction, then clean as described in the Maintenance section.
- Replace the hose and/or pump, if maintenance alone isn’t sufficient.
Spare Parts
Remote Control
W-100| Remote Control Assembly (includes W-101 and W-102)
W-101| Abestorm Remote Control
W-102| Abestorm Remote Control Cable
Display/Control
N-100| Abestorm Main Control Board
N-101| Abestorm Display Board
N-102| Abestorm RH/Temp. Sensor
Internal Components
N-801| Compressor
N-118| Compressor Capacitor
N-800| Coil Assembly
N-803| Condensate Pump Assembly
Fan Components
N-802| Abestorm Fan Motor
N-804| Abestorm Complete Fan Assembly
N-117| Fan Capacitor
Filters + External Components
N-200| Abestorm MERV-1
N-201| Abestorm MERV-10
N-202| Wheels
Cables
N-102| Temp/RH Sensor Cable
N-121| Display Ribbon Cable
N-122| CAT 5 Port Internal Cable
Accesspries
N-105| Abestorm Remote Control
Abestorm Solutions Inc. DEHUMIDIFIERS
Limited Warranty
This limited warranty starts from the date of purchase. Abestorm Solutions
Inc. warrants to the original purchaser that this Abestorm product is free
from manufacturing defects in material or workmanship for the limited warranty
period of:
-
Six (6) Month parts and labor. This includes the shipments charges for replacement parts or unit.
One (1) year parts and labor. This does not include the shipment charge to send the defective product back to be repaired or replaced. -
Three (3) years parts and labor on Refrigeration System ON LY (Compressor, Condenser, and evaporator). Transportation cost, not included
-
Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and evaporator). Transportation cost, not included
This limited warranty is valid only on products purchased from the manufacturer or Abestorm authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Abestorm Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact Abestorm at (888)276-9833 or sales@abestorm.com. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of Abestorm.
To receive warranty service, the purchaser must contactAbestorm at (888)276-9833 or sales@abestorm.com. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of Abestorm.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.